(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_ThermalZones_HighOrder_Validation_EmpiricalValidation_Warehouse_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_ThermalZones_HighOrder_Validation_EmpiricalValidation_Warehouse_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : AixLib.ThermalZones.HighOrder.Validation.EmpiricalValidation.Warehouse (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31536000.000000 - tolerance : 1e-06 - stepSize : 12614.4 warning: [fmi2Warning] Warehouse/logStatusWarning: Returning path (/tmp/tmpcp142ecp/Warehouse-lsrwfp99/temp/0001_Warehouse/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Data/ThermalZones/HighOrder/Validation/EmpiricalValidation/TRY2010_03_Warehouse.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "weather" from "/tmp/tmpcp142ecp/Warehouse-lsrwfp99/temp/0001_Warehouse/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Data/ThermalZones/HighOrder/Validation/EmpiricalValidation/TRY2010_03_Warehouse.txt" LOG_STDOUT | info | ... loading "Table" from "/tmp/tmpcp142ecp/Warehouse-lsrwfp99/temp/0001_Warehouse/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Data/ThermalZones/HighOrder/Validation/EmpiricalValidation/Warehouse.txt" info: Result file: AixLib_AixLib_ThermalZones_HighOrder_Validation_EmpiricalValidation_Warehouse_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter Warehouse.BuildingSpecifications.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.BuildingSpecifications.tableName will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.Room.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.Room.fileName will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.Room.tableName will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.idealHeaterCooler.zoneParam.TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.SOD.name[1] will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.SOD.name[2] will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.SOD.name[3] will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.SOD.name[4] will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.SOD.name[5] will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.WeatherData.delimiter will not be stored in the result file, because the signal type is not supported info: Variable Warehouse.weather.WeatherData.fileName will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.WeatherData.tableName will not be stored in the result file, because the signal type is not supported info: Parameter Warehouse.weather.formatTRY will not be stored in the result file, because the signal type is not supported info: Variable Warehouse.weather.tableName will not be stored in the result file, because the signal type is not supported info: 1 warnings info: 0 errors