(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_ModularAHU_Validation_AHU2_Preheater_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=7200 --stepSize=1 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_ModularAHU_Validation_AHU2_Preheater_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : AixLib.Systems.ModularAHU.Validation.AHU2_Preheater (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 1 info: Result file: AixLib_AixLib_Systems_ModularAHU_Validation_AHU2_Preheater_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter AHU2_Preheater.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter AHU2_Preheater.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter AHU2_Preheater.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter AHU2_Preheater.registerModule.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter AHU2_Preheater.registerModule.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter AHU2_Preheater.registerModule.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable AHU2_Preheater.registerModule.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter AHU2_Preheater.registerModule.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported LOG_STDOUT | warning | Removed more then one event from spatialDistribution. Step size to big! | | | | | time: 3740.000000, spatialDistribution index: 11, number of events: 3492 LOG_STDOUT | warning | Removed more then one event from spatialDistribution. Step size to big! | | | | | time: 3740.000000, spatialDistribution index: 10, number of events: 3493