Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 1.045/1.045, allocations: 153.8 MB / 173.4 MB, free: 4.875 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005358/0.0005358, allocations: 15.97 kB / 251.1 MB, free: 3.824 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1559/0.1564, allocations: 33.35 MB / 284.4 MB, free: 2.039 MB / 222.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.916/2.073, allocations: 374.2 MB / 0.6432 GB, free: 2.395 MB / 0.4981 GB Notification: Performance of NFInst.instExpressions: time 0.5918/2.665, allocations: 201.7 MB / 0.8402 GB, free: 2.336 MB / 0.6856 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0143/2.679, allocations: 241.4 kB / 0.8404 GB, free: 2.336 MB / 0.6856 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SinkP.mo:16:3-18:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:89:3-90:45:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:91:3-92:46:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:99:3-100:48:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:101:3-102:43:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceQ.mo:24:3-25:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourceQ.mo:17:3-18:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01268/2.692, allocations: 4.594 MB / 0.8449 GB, free: 2.305 MB / 0.6856 GB Notification: Performance of NFTyping.typeBindings: time 0.03143/2.723, allocations: 13.83 MB / 0.8584 GB, free: 1.902 MB / 0.6856 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.05403/2.777, allocations: 26.98 MB / 0.8848 GB, free: 1.336 MB / 0.6856 GB Notification: Performance of NFFlatten.flatten: time 0.08181/2.859, allocations: 83.38 MB / 0.9662 GB, free: 0.8711 MB / 0.7169 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04079/2.9, allocations: 23.96 MB / 0.9896 GB, free: 9.383 MB / 0.7481 GB Notification: Performance of NFEvalConstants.evaluate: time 0.05427/2.954, allocations: 28.56 MB / 1.017 GB, free: 13.96 MB / 0.7794 GB Notification: Performance of NFSimplifyModel.simplify: time 0.06026/3.014, allocations: 30.42 MB / 1.047 GB, free: 1.008 MB / 0.795 GB Notification: Performance of NFPackage.collectConstants: time 0.02087/3.035, allocations: 6.031 MB / 1.053 GB, free: 10.97 MB / 0.8106 GB Notification: Performance of NFFlatten.collectFunctions: time 0.0746/3.11, allocations: 30.54 MB / 1.083 GB, free: 12.69 MB / 0.8419 GB Notification: Performance of NFScalarize.scalarize: time 0.02916/3.139, allocations: 17.66 MB / 1.1 GB, free: 11.35 MB / 0.8575 GB Notification: Performance of NFVerifyModel.verify: time 0.05055/3.189, allocations: 21.48 MB / 1.121 GB, free: 6.148 MB / 0.8731 GB Notification: Performance of NFConvertDAE.convert: time 0.7231/3.912, allocations: 80.54 MB / 1.2 GB, free: 162.1 MB / 0.9044 GB Notification: Performance of FrontEnd - DAE generated: time 5.58e-06/3.912, allocations: 0 / 1.2 GB, free: 162.1 MB / 0.9044 GB Notification: Performance of FrontEnd: time 1.422e-06/3.912, allocations: 3.062 kB / 1.2 GB, free: 162.1 MB / 0.9044 GB Notification: Performance of Transformations before backend: time 0.001779/3.914, allocations: 0 / 1.2 GB, free: 162.1 MB / 0.9044 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 10686 * Number of variables: 10686 Notification: Performance of Generate backend data structure: time 0.244/4.158, allocations: 76.98 MB / 1.275 GB, free: 138.8 MB / 0.9044 GB Notification: Performance of prepare preOptimizeDAE: time 4.606e-05/4.158, allocations: 10.81 kB / 1.275 GB, free: 138.8 MB / 0.9044 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.04896/4.207, allocations: 7.044 MB / 1.282 GB, free: 135.4 MB / 0.9044 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.04526/4.253, allocations: 16.36 MB / 1.298 GB, free: 130 MB / 0.9044 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01757/4.27, allocations: 20.4 MB / 1.318 GB, free: 107.7 MB / 0.9044 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.02138/4.291, allocations: 2.877 MB / 1.321 GB, free: 104.8 MB / 0.9044 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1965/4.488, allocations: 70.65 MB / 1.39 GB, free: 33.18 MB / 0.9044 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001244/4.489, allocations: 38.97 kB / 1.39 GB, free: 33.16 MB / 0.9044 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.02265/4.512, allocations: 1.137 MB / 1.391 GB, free: 32.03 MB / 0.9044 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001102/4.513, allocations: 1.312 MB / 1.392 GB, free: 30.71 MB / 0.9044 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.2533/4.766, allocations: 86.37 MB / 1.476 GB, free: 8.484 MB / 0.9669 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.8535/5.62, allocations: 194 MB / 1.666 GB, free: 182.6 MB / 0.9982 GB Notification: Performance of preOpt comSubExp (simulation): time 0.1611/5.781, allocations: 70.91 MB / 1.735 GB, free: 118.6 MB / 0.9982 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.1137/5.895, allocations: 46.9 MB / 1.781 GB, free: 71.64 MB / 0.9982 GB Notification: Performance of preOpt evalFunc (simulation): time 0.2644/6.159, allocations: 82.11 MB / 1.861 GB, free: 5.695 MB / 1.014 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.4244/6.583, allocations: 54.81 MB / 1.914 GB, free: 0.4919 GB / 1.029 GB Notification: Performance of pre-optimization done (n=7248): time 0.0001065/6.583, allocations: 2 kB / 1.914 GB, free: 0.4919 GB / 1.029 GB Notification: Performance of matching and sorting (n=7256): time 1.22/7.804, allocations: 326.8 MB / 2.234 GB, free: 253.1 MB / 1.029 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0005233/7.804, allocations: 0.9697 MB / 2.235 GB, free: 252 MB / 1.029 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0159/7.82, allocations: 9.676 MB / 2.244 GB, free: 242.4 MB / 1.029 GB Notification: Performance of collectPreVariables (initialization): time 0.01842/7.839, allocations: 0.654 MB / 2.245 GB, free: 241.7 MB / 1.029 GB Notification: Performance of collectInitialEqns (initialization): time 0.005802/7.845, allocations: 7.928 MB / 2.252 GB, free: 233.8 MB / 1.029 GB Notification: Performance of collectInitialBindings (initialization): time 0.03025/7.875, allocations: 25.59 MB / 2.277 GB, free: 208.6 MB / 1.029 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.05517/7.93, allocations: 9.415 MB / 2.287 GB, free: 199.1 MB / 1.029 GB Notification: Performance of setup shared object (initialization): time 4.023e-05/7.93, allocations: 301.1 kB / 2.287 GB, free: 198.8 MB / 1.029 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.1106/8.041, allocations: 43.73 MB / 2.33 GB, free: 155 MB / 1.029 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.1192/8.16, allocations: 50.39 MB / 2.379 GB, free: 103.2 MB / 1.029 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.33/9.49, allocations: 287.6 MB / 2.66 GB, free: 389.2 MB / 1.029 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001537/9.49, allocations: 24 kB / 2.66 GB, free: 389.2 MB / 1.029 GB Notification: Performance of matching and sorting (n=8082) (initialization): time 0.431/9.921, allocations: 143.4 MB / 2.8 GB, free: 247.3 MB / 1.029 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001854/9.921, allocations: 103.4 kB / 2.8 GB, free: 247.2 MB / 1.029 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0006276/9.922, allocations: 147.9 kB / 2.8 GB, free: 247.1 MB / 1.029 GB Notification: Performance of postOpt tearingSystem (initialization): time 4.56/14.48, allocations: 2.266 GB / 5.066 GB, free: 399 MB / 1.029 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01835/14.5, allocations: 3.294 MB / 5.069 GB, free: 399 MB / 1.029 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.48/14.98, allocations: 189.6 MB / 5.254 GB, free: 293.9 MB / 1.029 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.06483/15.04, allocations: 6.069 MB / 5.26 GB, free: 290 MB / 1.029 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01764/15.06, allocations: 1.93 MB / 5.262 GB, free: 288.5 MB / 1.029 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP1.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurMP2.TwoPhaseFlowPipe.Q[4] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 414 * Number of states: 0 () * Number of discrete variables: 269 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal,$whenCondition1,SourceFumees.C.b,vanne_entree_TurbineMP.C2.b,vanne_entree_TurbineMP.C1.a,MelangeurPreTMP.Ce3.a,MelangeurPreTMP.Cs.b,MelangeurPreTMP.Ce2.a,MelangeurPreTMP.Ce1.a,VolumePreTHP.Cs3.b,VolumePreTHP.Cs2.b,VolumePreTHP.Cs1.b,VolumePreTHP.Ce.a,Vanne_alimentationMPHP2.C2.b,Vanne_alimentationMPHP2.C1.a,Vanne_alimentationMPHP1.C2.b,Vanne_alimentationMPHP1.C1.a,VolumeECO_HP2_3.Ce3.a,VolumeECO_HP2_3.Cs.b,VolumeECO_HP2_3.Ce2.a,VolumeECO_HP2_3.Ce1.a,VolumeECO_HP1_2.Ce3.a,VolumeECO_HP1_2.Cs.b,VolumeECO_HP1_2.Ce2.a,VolumeECO_HP1_2.Ce1.a,vanne_entree_TurbineHP.C2.b,vanne_entree_TurbineHP.C1.a,lumpedStraightPipeK2.C2.b,lumpedStraightPipeK2.C1.a,CapteurDebitVapCondenseur.C2.b,CapteurDebitVapCondenseur.C1.a,CapteurDebitEauCondenseur.C2.b,CapteurDebitEauCondenseur.C1.a,CapteurDebitEauBPsortie.C2.b,CapteurDebitEauBPsortie.C1.a,CapteurDebitEauBP.C2.b,CapteurDebitEauBP.C1.a,CapteurDebitVapBP.C2.b,CapteurDebitVapBP.C1.a,CapteurDebitVapMP.C2.b,CapteurDebitVapMP.C1.a,CapteurDebitEauMP.C2.b,CapteurDebitEauMP.C1.a,CapteurDebitEauHP.C2.b,CapteurDebitEauHP.C1.a,CapteurDebitVapHP.C2.b,CapteurDebitVapHP.C1.a,vanne_extraction.C2.b,vanne_extraction.C1.a,perteChargeK2.C2.b,perteChargeK2.C1.a,PompeAlimBP.C2.b,PompeAlimBP.C1.a,perteChargeK.C2.b,perteChargeK.C1.a,perteChargeK8.C2.b,perteChargeK8.C1.a,perteChargeK3.C2.b,perteChargeK3.C1.a,PerteChargeZero2.C2.b,PerteChargeZero2.C1.a,DoubleDebitBP.Cs.b,DoubleDebitBP.Ce.a,MoitieDebitBP.Cs.b,MoitieDebitBP.Ce.a,PompeAlimHP.C2.b,PompeAlimHP.C1.a,PompeAlimMP.C2.b,PompeAlimMP.C1.a,VolumeAlimMPHP.Cs2.b,VolumeAlimMPHP.Cs1.b,VolumeAlimMPHP.Ce2.a,VolumeAlimMPHP.Ce1.a,perteChargeKCond1.C2.b,perteChargeKCond1.C1.a,VolumeCond1.Ce3.a,VolumeCond1.Cs.b,VolumeCond1.Ce2.a,VolumeCond1.Ce1.a,perteChargeK1.C2.b,perteChargeK1.C1.a,PuitsCaloporteur.C.a,SourceCaloporteur.C.b,Condenseur.Cse.b,Condenseur.Cee.a,Condenseur.Cl.b,Condenseur.Cv.a,MoitieDebitHP.Cs.b,MoitieDebitHP.Ce.a,DoubleDebitMP.Cs.b,DoubleDebitMP.Ce.a,DoubleDebitHP.Cs.b,DoubleDebitHP.Ce.a,TurbineBP.Cs.b,TurbineBP.Ce.a,MelangeurPostTMP1.Ce3.a,MelangeurPostTMP1.Cs.b,MelangeurPostTMP1.Ce2.a,MelangeurPostTMP1.Ce1.a,TurbineMP.Cs.b,TurbineMP.Ce.a,TurbineHP.Cs.b,TurbineHP.Ce.a,EconomiseurBP.TwoPhaseFlowPipe.C2.b,EconomiseurBP.TwoPhaseFlowPipe.C1.a,EconomiseurBP.ExchangerFlueGasesMetal.C2.b,EconomiseurBP.ExchangerFlueGasesMetal.C1.a,PuitsFumees.C.a,SurchauffeurBP.TwoPhaseFlowPipe.C2.b,SurchauffeurBP.TwoPhaseFlowPipe.C1.a,SurchauffeurBP.ExchangerFlueGasesMetal.C2.b,SurchauffeurBP.ExchangerFlueGasesMetal.C1.a,Vanne_alimentationMPHP.C2.b,Vanne_alimentationMPHP.C1.a,EvaporateurBP.TwoPhaseFlowPipe.C2.b,EvaporateurBP.TwoPhaseFlowPipe.C1.a,EvaporateurBP.ExchangerFlueGasesMetal.C2.b,EvaporateurBP.ExchangerFlueGasesMetal.C1.a,VolumeEvapBP.Ce3.a,VolumeEvapBP.Cs.b,VolumeEvapBP.Ce2.a,VolumeEvapBP.Ce1.a,GainChargeBP.C2.b,GainChargeBP.C1.a,vanne_alimentationBP.C2.b,vanne_alimentationBP.C1.a,vanne_vapeurBP.C2.b,vanne_vapeurBP.C1.a,BallonBP.Cs.b,BallonBP.Ce3.a,BallonBP.Ce2.a,BallonBP.Cv.b,BallonBP.Cd.b,BallonBP.Cm.a,BallonBP.Ce1.a,SurchauffeurMP3.TwoPhaseFlowPipe.C2.b,SurchauffeurMP3.TwoPhaseFlowPipe.C1.a,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurMP2.TwoPhaseFlowPipe.C2.b,SurchauffeurMP2.TwoPhaseFlowPipe.C1.a,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.a,MelangeurHPMP.Cs2.b,MelangeurHPMP.Cs1.b,MelangeurHPMP.Ce2.a,MelangeurHPMP.Ce1.a,SurchauffeurMP1.TwoPhaseFlowPipe.C2.b,SurchauffeurMP1.TwoPhaseFlowPipe.C1.a,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.a,EconomiseurMP.TwoPhaseFlowPipe.C2.b,EconomiseurMP.TwoPhaseFlowPipe.C1.a,EconomiseurMP.ExchangerFlueGasesMetal.C2.b,EconomiseurMP.ExchangerFlueGasesMetal.C1.a,VolumeEvapMP.Ce3.a,VolumeEvapMP.Cs.b,VolumeEvapMP.Ce2.a,VolumeEvapMP.Ce1.a,GainChargeMP.C2.b,GainChargeMP.C1.a,EvaporateurMP.TwoPhaseFlowPipe.C2.b,EvaporateurMP.TwoPhaseFlowPipe.C1.a,EvaporateurMP.ExchangerFlueGasesMetal.C2.b,EvaporateurMP.ExchangerFlueGasesMetal.C1.a,vanne_vapeurMP.C2.b,vanne_vapeurMP.C1.a,vanne_alimentationMP.C2.b,vanne_alimentationMP.C1.a,BallonMP.Cs.b,BallonMP.Ce3.a,BallonMP.Ce2.a,BallonMP.Cv.b,BallonMP.Cd.b,BallonMP.Cm.a,BallonMP.Ce1.a,SurchauffeurHP3.TwoPhaseFlowPipe.C2.b,SurchauffeurHP3.TwoPhaseFlowPipe.C1.a,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP2.TwoPhaseFlowPipe.C2.b,SurchauffeurHP2.TwoPhaseFlowPipe.C1.a,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP1.TwoPhaseFlowPipe.C2.b,EconomiseurHP1.TwoPhaseFlowPipe.C1.a,EconomiseurHP1.ExchangerFlueGasesMetal.C2.b,EconomiseurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP2.TwoPhaseFlowPipe.C2.b,EconomiseurHP2.TwoPhaseFlowPipe.C1.a,EconomiseurHP2.ExchangerFlueGasesMetal.C2.b,EconomiseurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP3.TwoPhaseFlowPipe.C2.b,EconomiseurHP3.TwoPhaseFlowPipe.C1.a,EconomiseurHP3.ExchangerFlueGasesMetal.C2.b,EconomiseurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP1.TwoPhaseFlowPipe.C2.b,SurchauffeurHP1.TwoPhaseFlowPipe.C1.a,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP4.TwoPhaseFlowPipe.C2.b,EconomiseurHP4.TwoPhaseFlowPipe.C1.a,EconomiseurHP4.ExchangerFlueGasesMetal.C2.b,EconomiseurHP4.ExchangerFlueGasesMetal.C1.a,EvaporateurHP.TwoPhaseFlowPipe.C2.b,EvaporateurHP.TwoPhaseFlowPipe.C1.a,EvaporateurHP.ExchangerFlueGasesMetal.C2.b,EvaporateurHP.ExchangerFlueGasesMetal.C1.a,VolumeEvapHP.Ce3.a,VolumeEvapHP.Cs.b,VolumeEvapHP.Ce2.a,VolumeEvapHP.Ce1.a,GainChargeHP.C2.b,GainChargeHP.C1.a,vanne_vapeurHP.C2.b,vanne_vapeurHP.C1.a,vanne_alimentationHP.C2.b,vanne_alimentationHP.C1.a,BallonHP.Cs.b,BallonHP.Ce3.a,BallonHP.Ce2.a,BallonHP.Cv.b,BallonHP.Cd.b,BallonHP.Cm.a,BallonHP.Ce1.a,MelangeurPreTMP.Ce3.b,MelangeurPreTMP.Ce2.b,VolumePreTHP.Cs2.a,VolumePreTHP.Cs1.a,VolumeECO_HP2_3.Ce3.b,VolumeECO_HP2_3.Ce2.b,VolumeECO_HP1_2.Ce3.b,VolumeECO_HP1_2.Ce2.b,VolumeAlimMPHP.Ce2.b,VolumeCond1.Ce2.b,VolumeCond1.Ce1.b,MelangeurPostTMP1.Ce3.b,VolumeEvapBP.Ce3.b,VolumeEvapBP.Ce2.b,BallonBP.Ce3.b,BallonBP.Ce2.b,MelangeurHPMP.Cs1.a,VolumeEvapMP.Ce3.b,VolumeEvapMP.Ce2.b,BallonMP.Cs.a,BallonMP.Ce3.b,BallonMP.Ce2.b,VolumeEvapHP.Ce3.b,VolumeEvapHP.Ce2.b,BallonHP.Cs.a,BallonHP.Ce3.b,BallonHP.Ce2.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1368): * Single equations (assignments): 1299 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 49 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 13 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(4,1,62.5%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,15), (1,1), (1,3), (2,11), (1,15), (1,1), (318,2904), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.04552/15.11, allocations: 8.893 MB / 5.27 GB, free: 280.9 MB / 1.029 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.022/15.13, allocations: 2.989 MB / 5.273 GB, free: 279.5 MB / 1.029 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.4778/15.61, allocations: 158 MB / 5.428 GB, free: 142 MB / 1.029 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.436/16.04, allocations: 139.7 MB / 5.564 GB, free: 1.816 MB / 1.029 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002775/16.04, allocations: 20 kB / 5.564 GB, free: 1.797 MB / 1.029 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001315/16.05, allocations: 285.1 kB / 5.564 GB, free: 1.52 MB / 1.029 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.989/17.03, allocations: 231.7 MB / 5.791 GB, free: 364.2 MB / 1.029 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001095/17.04, allocations: 71.94 kB / 5.791 GB, free: 364.1 MB / 1.029 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.0893/17.12, allocations: 16.26 MB / 5.807 GB, free: 348.1 MB / 1.029 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1298/17.25, allocations: 45.02 MB / 5.851 GB, free: 304.1 MB / 1.029 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.01827/17.27, allocations: 1.912 MB / 5.852 GB, free: 302.2 MB / 1.029 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.7511/18.02, allocations: 321.2 MB / 6.166 GB, free: 400.3 MB / 1.029 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 7.794e-06/18.02, allocations: 14.34 kB / 6.166 GB, free: 400.3 MB / 1.029 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.5862/18.61, allocations: 207.8 MB / 6.369 GB, free: 324.2 MB / 1.029 GB Notification: Performance of postOpt removeConstants (simulation): time 0.04574/18.66, allocations: 11.63 MB / 6.38 GB, free: 315.6 MB / 1.029 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02058/18.68, allocations: 1.171 MB / 6.382 GB, free: 314.5 MB / 1.029 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.0654/18.74, allocations: 6.049 MB / 6.387 GB, free: 310.5 MB / 1.029 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0237/18.77, allocations: 4.332 MB / 6.392 GB, free: 307.1 MB / 1.029 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01735/18.78, allocations: 2.049 MB / 6.394 GB, free: 305 MB / 1.029 GB Notification: Performance of sorting global known variables: time 0.01095/18.79, allocations: 6.046 MB / 6.4 GB, free: 299 MB / 1.029 GB Notification: Performance of sort global known variables: time 1e-07/18.79, allocations: 0 / 6.4 GB, free: 299 MB / 1.029 GB Notification: Performance of remove unused functions: time 0.06912/18.86, allocations: 15.45 MB / 6.415 GB, free: 283.9 MB / 1.029 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 40 * Number of states: 249 (MelangeurPreTMP.h,MelangeurPreTMP.P,VolumePreTHP.h,VolumePreTHP.P,VolumeECO_HP2_3.h,VolumeECO_HP2_3.P,VolumeECO_HP1_2.h,VolumeECO_HP1_2.P,regulation_Niveau_Condenseur.pT1_3.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_HP.pIsat.Integrateur1.x,VolumeAlimMPHP.h,VolumeCond1.h,Condenseur.Vl,Condenseur.hv,Condenseur.hl,Condenseur.P,MelangeurPostTMP1.h,EconomiseurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[1],SurchauffeurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[1],EvaporateurBP.TwoPhaseFlowPipe.h[4],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[1],VolumeEvapBP.h,BallonBP.Vl,BallonBP.Tp,BallonBP.hv,BallonBP.hl,BallonBP.P,SurchauffeurMP3.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[1],MelangeurHPMP.h,SurchauffeurMP1.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[1],EconomiseurMP.TwoPhaseFlowPipe.h[4],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[1],VolumeEvapMP.h,EvaporateurMP.TwoPhaseFlowPipe.h[4],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[1],BallonMP.Vl,BallonMP.Tp,BallonMP.hv,BallonMP.hl,BallonMP.P,SurchauffeurHP3.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[1],EconomiseurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[1],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[1],EconomiseurHP4.TwoPhaseFlowPipe.h[4],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[1],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[1],EvaporateurHP.TwoPhaseFlowPipe.h[4],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[1],VolumeEvapHP.h,BallonHP.Vl,BallonHP.Tp,BallonHP.hv,BallonHP.hl,BallonHP.P) * Number of discrete variables: 9 ($whenCondition1,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (4826): * Single equations (assignments): 4368 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 276 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 170 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 1 system {1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 69 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,2,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 101 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,2), (1,2), (1,5), (1,2), (1,2), (1,3), (1,5), (3,16), (1,5), (1,3), (6,14), (1,3), (6,14), (1,3), (1,3), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (1,5), (1,3), (8,15), (1,3), (1,4), (1,4), (1,4)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02894/18.89, allocations: 4.625 MB / 6.419 GB, free: 280 MB / 1.029 GB Notification: Performance of simCode: created initialization part: time 0.3468/19.24, allocations: 172.4 MB / 6.588 GB, free: 102.7 MB / 1.029 GB Notification: Performance of simCode: created event and clocks part: time 1.847e-05/19.24, allocations: 5.219 kB / 6.588 GB, free: 102.7 MB / 1.029 GB Notification: Performance of simCode: created simulation system equations: time 0.5002/19.74, allocations: 81.88 MB / 6.668 GB, free: 382.8 MB / 1.029 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.09612/19.83, allocations: 15.35 MB / 6.683 GB, free: 381.5 MB / 1.029 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.4365/20.27, allocations: 162.1 MB / 6.841 GB, free: 347.1 MB / 1.029 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.04607/20.32, allocations: 23.56 MB / 6.864 GB, free: 342.4 MB / 1.029 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.02764/20.35, allocations: 3.032 MB / 6.867 GB, free: 342.2 MB / 1.029 GB Notification: Performance of SimCode: time 1.894e-06/20.35, allocations: 0 / 6.867 GB, free: 342.2 MB / 1.029 GB Notification: Performance of Templates: time 31.39/51.74, allocations: 17.58 GB / 24.45 GB, free: 336.6 MB / 1.03 GB " [Timeout remaining time 608] make -j1 -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile [Timeout 660] make -j1 -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DOMC_BUILD -DUSE_THREAD -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.o OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.cpp In file included from OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgLoopMain.cpp:273: ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:93:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp2062.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:94:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp2062.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:95:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp2062.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:96:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp2062.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:97:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp2062.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:98:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_pt_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_pt_ = get<0>(tmp2062.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:99:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cv_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cv_ = get<0>(tmp2062.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:100:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_P_ = get<1>(tmp2062.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:101:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_T_ = get<1>(tmp2062.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:102:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_rho_ = get<1>(tmp2062.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:103:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_h_ = get<1>(tmp2062.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:104:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cp_ = get<1>(tmp2062.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:105:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_pt_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_pt_ = get<1>(tmp2062.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:106:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cv_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cv_ = get<1>(tmp2062.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:112:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp2063.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:113:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp2063.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:114:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp2063.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:115:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp2063.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:116:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp2063.data).cp_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.o] Error 1 [Calling os._exit(0), Time elapsed: 58.619718982838094] Failed to read output from testmodel.py, exit status != 0: 51.87577805202454 51.885511431 47.970259177 Calling exit ...