Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Chemical_master_Chemical.Examples.SimpleReactionsWithJunction3.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00159/0.00159, allocations: 104.4 kB / 19.7 MB, free: 2.125 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001646/0.001646, allocations: 213.8 kB / 22.99 MB, free: 4.945 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.454/1.454, allocations: 230.6 MB / 256.8 MB, free: 7.801 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo): time 0.1405/0.1405, allocations: 24 MB / 337.2 MB, free: 10.85 MB / 270.1 MB " [Timeout remaining time 180] Using package Chemical with version 2.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Chemical.Examples.SimpleReactionsWithJunction3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Chemical_master_Chemical.Examples.SimpleReactionsWithJunction3") translateModel(Chemical.Examples.SimpleReactionsWithJunction3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Chemical_master_Chemical.Examples.SimpleReactionsWithJunction3") [Timeout 660] "Notification: Chemical requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002098/0.002098, allocations: 63.89 kB / 472.5 MB, free: 6.871 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3473/0.3494, allocations: 59.9 MB / 0.5199 GB, free: 9.676 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1084:7-1084:40:writable] Warning: An inner declaration for outer component dropOfCommons could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1084:7-1084:40:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"dropOfCommons\" component but an inner \"dropOfCommons\" component is not defined. Use Chemical.DropOfCommons in your model to specify system properties. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1730:7-1730:66:writable] Warning: An inner declaration for outer component system could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1730:7-1730:66:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"system\" component but an inner \"system\" component is not defined. For simulation drag Modelica.Fluid.System into your model to specify system properties. Notification: Performance of NFInst.instantiate(Chemical.Examples.SimpleReactionsWithJunction3): time 0.07672/0.4261, allocations: 29.04 MB / 0.5483 GB, free: 10.66 MB / 398.1 MB Notification: Performance of NFInst.instExpressions: time 0.01583/0.4419, allocations: 8.713 MB / 0.5568 GB, free: 2.797 MB / 398.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.00192/0.4439, allocations: 39.75 kB / 0.5568 GB, free: 2.758 MB / 398.1 MB Notification: Performance of NFTyping.typeComponents: time 0.004572/0.4484, allocations: 1.573 MB / 0.5584 GB, free: 1.488 MB / 398.1 MB Notification: Performance of NFTyping.typeBindings: time 0.003497/0.4519, allocations: 0.9654 MB / 0.5593 GB, free: 0.6797 MB / 398.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.007083/0.459, allocations: 3.311 MB / 0.5626 GB, free: 13.88 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1331:3-1331:46:writable] Error: Parameter r_ref.nextProducts[1].data.MM has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0007598/0.4598, allocations: 303.8 kB / 0.5628 GB, free: 13.62 MB / 414.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.0087294303812087] Failed to read output from testmodel.py, exit status != 0: 0.4673825311474502 0.481572904 -1.0 Calling exit ...