Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_11_Buildings.Templates.Components.Validation.Pumps.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00163/0.00163, allocations: 104.4 kB / 19.7 MB, free: 2.125 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001849/0.001849, allocations: 213.5 kB / 22.99 MB, free: 4.945 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.458/1.458, allocations: 230.6 MB / 256.8 MB, free: 7.812 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/package.mo): time 2.739/2.739, allocations: 476 MB / 0.7707 GB, free: 4.773 MB / 0.6231 GB " [Timeout remaining time 177] Using package Buildings with version 11.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_11_Buildings.Templates.Components.Validation.Pumps") translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_11_Buildings.Templates.Components.Validation.Pumps") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00214/0.00214, allocations: 67.98 kB / 1.118 GB, free: 41.05 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2988/0.301, allocations: 170 MB / 1.284 GB, free: 12 MB / 0.9825 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Components.Validation.Pumps): time 1.283/1.584, allocations: 405.3 MB / 1.68 GB, free: 56.64 MB / 1.295 GB Notification: Performance of NFInst.instExpressions: time 0.1297/1.713, allocations: 89.9 MB / 1.767 GB, free: 45.62 MB / 1.295 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02736/1.741, allocations: 0.6947 MB / 1.768 GB, free: 45.62 MB / 1.295 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Fluid/Movers/BaseClasses/Characteristics/flowParameters.mo:5:3-6:57:writable] Error: Dimension 1 of 'V_flow' could not be deduced from the component's binding equation 'datPumMul.per.pressure.V_flow'. Notification: Performance of FrontEnd: time 0.004066/1.745, allocations: 1.249 MB / 1.769 GB, free: 45.44 MB / 1.295 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 7.973457820247859] Failed to read output from testmodel.py, exit status != 0: 2.2658679648302495 1.762926008 -1.0 Calling exit ...