Environment - simulationEnvironment:
publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/
superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/
startTime=0
stopTime=4e+06
tolerance=1e-06
numberOfIntervals=4444
stepSize=900.09
Regular simulation: ./TransiEnt_TransiEnt.Storage.Electrical.Check.TestSuperCapacitor  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
DASKR--  AT T (=R1) AND STEPSIZE H (=R2) THE                                    
      In above,  R1 =   1.0027590741414E+04   R2 =   7.6083856278073E-12
DASKR--  ERROR TEST FAILED REPEATEDLY OR WITH ABS(H)=HMIN                       
LOG_STDOUT        | warning | DDASSL had repeated error test failures on the last attempted step.
LOG_STDOUT        | warning | can't continue. time = 10027.590741
LOG_STDOUT        | info    | model terminate | Integrator failed. | Simulation terminated at time 10027.6
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0227393s          reading init.xml
|                 | |       | | |   0.00142838s          reading info.xml
|                 | |       | | |  0.000160251s [  0.3%] pre-initialization
|                 | |       | | |    0.0555315s [ 97.8%] initialization
|                 | |       | | |  0.000326131s [  0.6%] steps
|                 | |       | | |  0.000456028s [  0.8%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |     9.76e-05s [  0.2%] event-handling
|                 | |       | | |   1.4758e-05s [  0.0%] overhead
|                 | |       | | |  0.000197782s [  0.3%] simulation
|                 | |       | | |    0.0567841s [100.0%] total
|                 | |       | | events
|                 | |       | | |     3 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   298 steps taken
|                 | |       | | |   559 calls of functionODE
|                 | |       | | |   327 evaluations of jacobian
|                 | |       | | |    82 error test failures
|                 | |       | | |     6 convergence test failures
|                 | |       | | | 0.00020009s time of jacobian evaluation