Environment - simulationEnvironment:
publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/
superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/
startTime=0
stopTime=18000
tolerance=1e-06
numberOfIntervals=2500
stepSize=7.2
Regular simulation: ./TransiEnt_TransiEnt.Storage.Electrical.Base.Check.TestGenericElectricStorage  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STDOUT        | info    | Chattering detected around time 3599.60264275..3599.60344117 (100 state events in a row with a total time delta less than the step size 7.2). This can be a performance bottleneck. Use -lv LOG_EVENTS for more information. The zero-crossing was: lossyStorage.storageModel.E >= lossyStorage.storageModel.isStorageFull.threshold
LOG_ASSERT        | debug   | Aborting simulation due to chattering being detected and the simulation flags requesting we do not continue further.