Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem.conf.json
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo): time 2.315/2.315, allocations: 396 MB / 418.6 MB, free: 9.867 MB / 334.1 MB
"
[Timeout remaining time 177]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0008209/0.0008209, allocations: 42.66 kB / 0.5062 GB, free: 6.512 MB / 398.1 MB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) [Timeout 180]
"[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location).
Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 1.021/1.021, allocations: 128.9 MB / 0.7294 GB, free: 7.938 MB / 0.4981 GB
"
[Timeout remaining time 179]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01205/0.01205, allocations: 0.8959 MB / 0.8549 GB, free: 7.73 MB / 0.6231 GB
"
[Timeout remaining time 179]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.3051/0.3051, allocations: 45.28 MB / 1.024 GB, free: 75.3 MB / 0.6232 GB
"
[Timeout remaining time 179]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.1055/0.1055, allocations: 13.77 MB / 1.17 GB, free: 65.58 MB / 0.6232 GB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001597/0.001597, allocations: 110.8 kB / 1.307 GB, free: 10.43 MB / 0.7013 GB
"
[Timeout remaining time 179]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001572/0.001572, allocations: 200.3 kB / 1.444 GB, free: 200 MB / 0.7638 GB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.683/1.683, allocations: 225.6 MB / 1.801 GB, free: 30.91 MB / 0.7794 GB
"
[Timeout remaining time 178]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0008843/0.0008843, allocations: 31.95 kB / 1.989 GB, free: 6.805 MB / 0.9357 GB
"
[Timeout remaining time 179]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0009716/0.0009716, allocations: 29.88 kB / 2.177 GB, free: 216.6 MB / 0.9825 GB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.971/1.971, allocations: 223.6 MB / 2.583 GB, free: 59.59 MB / 1.014 GB
"
[Timeout remaining time 177]
Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo)
Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo)
Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo)
Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo)
Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo)
Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo)
Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo)
Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo)
Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo)
Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo)
Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo)
Using package Buildings with version 9.1.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo)
Running command: translateModel(TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem")
translateModel(TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem") [Timeout 660]
"Notification: Skipped loading package TILMedia (1.8.1 ClaRa) using MODELICAPATH /home/hudson/saved_omc/libraries/.openmodelica/libraries (uses-annotation may be wrong).
Notification: Skipped loading package TILMedia (1.8.0 ClaRa) using MODELICAPATH /home/hudson/saved_omc/libraries/.openmodelica/libraries (uses-annotation may be wrong).
Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, \"1.8.1\") to run the conversion script or proceed with potential issues as a result.
Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.3 is used instead which states that it is fully compatible without conversion script needed.
Notification: Performance of FrontEnd - loaded program: time 0.0496/0.0496, allocations: 20.77 MB / 3.093 GB, free: 61.1 MB / 1.264 GB
Notification: Performance of FrontEnd - Absyn->SCode: time 0.6584/0.708, allocations: 236.6 MB / 3.324 GB, free: 12 kB / 1.436 GB
Notification: Automatically loaded package TILMedia 1.8.2 ClaRa due to usage.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/Control/ControllerPumpSolarCollectorTandG.mo:58:1-58:119:writable] Warning: Parameter solarThermalSystem_5LayerStorage.controller.T has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/Control/ControllerPumpSolarCollectorTandG.mo:67:1-68:103:writable] Warning: Parameter solarThermalSystem_5LayerStorage.controller.yMax has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/Control/ControllerPumpSolarCollectorTandG.mo:58:1-58:119:writable] Warning: Parameter solarThermalSystem_10LayerStorage1.controller.T has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/Control/ControllerPumpSolarCollectorTandG.mo:67:1-68:103:writable] Warning: Parameter solarThermalSystem_10LayerStorage1.controller.yMax has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/Control/ControllerPumpSolarCollectorTandG.mo:58:1-58:119:writable] Warning: Parameter solarThermalSystem_3LayerStorage.controller.T has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/Control/ControllerPumpSolarCollectorTandG.mo:67:1-68:103:writable] Warning: Parameter solarThermalSystem_3LayerStorage.controller.yMax has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Heat/HotWaterStorage_constProp_L4/HotWaterStorage_constProp_L4.mo:46:3-46:50:writable] Warning: An inner declaration for outer component modelStatistics could not be found and was automatically generated.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Heat/HotWaterStorage_constProp_L4/HotWaterStorage_constProp_L4.mo:46:3-46:50:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"modelStatistics\" but it does not contain an inner \"modelStatistics\" component. Drag model TransiEnt.ModelStatistics into your model to make it work.
Notification: Performance of NFInst.instantiate(TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem): time 0.2785/0.9865, allocations: 105.7 MB / 3.427 GB, free: 6.281 MB / 1.545 GB
Notification: Performance of NFInst.instExpressions: time 0.1061/1.093, allocations: 39.5 MB / 3.466 GB, free: 14.68 MB / 1.592 GB
Notification: Performance of NFInst.updateImplicitVariability: time 0.02904/1.122, allocations: 492.8 kB / 3.466 GB, free: 14.19 MB / 1.592 GB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsHeat.mo:69:3-69:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsHeat.mo:69:3-69:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsHeat.mo:69:3-69:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6).
Notification: Performance of NFTyping.typeComponents: time 0.01577/1.137, allocations: 3.974 MB / 3.47 GB, free: 10.2 MB / 1.592 GB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'.
Warning: Allowing casting of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass to Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead!
Warning: Allowing casting of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil to Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead!
Warning: Allowing casting of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas to Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead!
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/SolarThermal/SystemModels/SolarThermalSystem_5LayerStorage.mo:53:3-53:471:writable] Error: Type mismatch in binding typeOfPrimaryEnergyCarrier = if solarThermalSystem_5LayerStorage.fuel == TransiEnt.Basics.Types.FuelType.Gas then 3 else if solarThermalSystem_5LayerStorage.fuel == TransiEnt.Basics.Types.FuelType.Oil then 5 else if solarThermalSystem_5LayerStorage.fuel == TransiEnt.Basics.Types.FuelType.Pellets then 8 else 0, expected subtype of enumeration TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat(BrownCoal, BlackCoal, NaturalGas, DistrictHeating, Oil, Electricity, Solar, Biomass, Garbage, Others), got type Integer.
Notification: Performance of FrontEnd: time 0.005044/1.142, allocations: 1.234 MB / 3.472 GB, free: 8.957 MB / 1.592 GB
"
[Timeout remaining time 657]
[Calling sys.exit(0), Time elapsed: 19.203327079303563]
Failed to read output from testmodel.py, exit status != 0:
3.382256517186761 3.39135413 -1.0
Calling exit ...
<OMPython.OMCSessionZMQ object at 0x7f8145bf57b0>