Environment - simulationEnvironment:
publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/
superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/
startTime=0
stopTime=4000
tolerance=1e-06
numberOfIntervals=2500
stepSize=1.6
Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Wind.Base.Check.Test_RoughnessFilter  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/Wind_Hamburg_3600s_TMY.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/Wind_Hamburg_3600s_TMY.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/Wind_Hamburg_3600s_TMY.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0114089s          reading init.xml
|                 | |       | | |  0.000892774s          reading info.xml
|                 | |       | | |    9.065e-05s [  0.2%] pre-initialization
|                 | |       | | |    0.0491164s [ 92.2%] initialization
|                 | |       | | |     5.61e-07s [  0.0%] steps
|                 | |       | | |    2.787e-06s [  0.0%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |    1.427e-05s [  0.0%] event-handling
|                 | |       | | |   0.00182999s [  3.4%] overhead
|                 | |       | | |   0.00220449s [  4.1%] simulation
|                 | |       | | |    0.0532592s [100.0%] total
|                 | |       | | events
|                 | |       | | |     2 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: euler
|                 | |       | | |  6630 steps taken
|                 | |       | | |  6630 calls of functionODE
|                 | |       | | |     0 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.