Environment - simulationEnvironment:
publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/
superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/
startTime=0
stopTime=30000
tolerance=1e-06
numberOfIntervals=500
stepSize=60
Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Others.Check.TestPumpedStoragePlant  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0314464s          reading init.xml
|                 | |       | | |   0.00231741s          reading info.xml
|                 | |       | | |  0.000195387s [  0.4%] pre-initialization
|                 | |       | | |    0.0476593s [ 88.6%] initialization
|                 | |       | | |    3.347e-06s [  0.0%] steps
|                 | |       | | |   0.00111242s [  2.1%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   0.00100662s [  1.9%] event-handling
|                 | |       | | |  0.000758471s [  1.4%] overhead
|                 | |       | | |   0.00303719s [  5.6%] simulation
|                 | |       | | |    0.0537727s [100.0%] total
|                 | |       | | events
|                 | |       | | |    16 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   959 steps taken
|                 | |       | | |  1438 calls of functionODE
|                 | |       | | |   526 evaluations of jacobian
|                 | |       | | |    24 error test failures
|                 | |       | | |    78 convergence test failures
|                 | |       | | | 0.000386147s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.