Environment - simulationEnvironment:
publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/
superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/
startTime=0
stopTime=200
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.08
Regular simulation: ./TransiEnt_TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.LocalPlantInteractingWithUCTE_withIncident  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt"
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0306276s          reading init.xml
|                 | |       | | |   0.00244575s          reading info.xml
|                 | |       | | |  0.000211167s [  0.4%] pre-initialization
|                 | |       | | |    0.0473342s [ 80.9%] initialization
|                 | |       | | |    2.375e-06s [  0.0%] steps
|                 | |       | | |  0.000845158s [  1.4%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |  0.000163119s [  0.3%] event-handling
|                 | |       | | |   0.00266277s [  4.5%] overhead
|                 | |       | | |    0.0073249s [ 12.5%] simulation
|                 | |       | | |    0.0585436s [100.0%] total
|                 | |       | | events
|                 | |       | | |     1 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   206 steps taken
|                 | |       | | |   279 calls of functionODE
|                 | |       | | |   110 evaluations of jacobian
|                 | |       | | |     5 error test failures
|                 | |       | | |     8 convergence test failures
|                 | |       | | | 0.000755516s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.