Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=3600 tolerance=1e-09 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./TransiEnt_TransiEnt.Examples.Electric.ElectricGrid_SecondaryBalancing -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0422045s reading init.xml | | | | | | 0.00276285s reading info.xml | | | | | | 0.000270738s [ 0.4%] pre-initialization | | | | | | 0.0495783s [ 64.5%] initialization | | | | | | 1.4327e-05s [ 0.0%] steps | | | | | | 0.00297858s [ 3.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00447554s [ 5.8%] event-handling | | | | | | 0.00326365s [ 4.2%] overhead | | | | | | 0.0162895s [ 21.2%] simulation | | | | | | 0.0768706s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1432 steps taken | | | | | | 1951 calls of functionODE | | | | | | 238 evaluations of jacobian | | | | | | 73 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00166259s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.