Environment - simulationEnvironment:
publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/
superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/
superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/
startTime=0
stopTime=7200
tolerance=1e-06
numberOfIntervals=2500
stepSize=2.88
Regular simulation: ./TransiEnt_TransiEnt.Components.Statistics.Check.TestBalancingPowerStatistics  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt"
LOG_STDOUT        | info    | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt
LOG_STDOUT        | info    | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0245698s          reading init.xml
|                 | |       | | |   0.00184152s          reading info.xml
|                 | |       | | |   0.00020791s [  0.3%] pre-initialization
|                 | |       | | |     0.050964s [ 80.7%] initialization
|                 | |       | | |    3.045e-06s [  0.0%] steps
|                 | |       | | |   0.00104496s [  1.7%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   0.00128242s [  2.0%] event-handling
|                 | |       | | |    0.0029367s [  4.7%] overhead
|                 | |       | | |   0.00669675s [ 10.6%] simulation
|                 | |       | | |    0.0631358s [100.0%] total
|                 | |       | | events
|                 | |       | | |    14 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   494 steps taken
|                 | |       | | |   620 calls of functionODE
|                 | |       | | |   284 evaluations of jacobian
|                 | |       | | |    26 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 9.0368e-05s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.