Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.1 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_DesignPoint -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/TurboComponent/dp_tau_centrifugal.mo:99:3-110:28:writable] | | | | | | | | ==================================================================================== | | | | ThermoFluidStream WARNING – DEPRECATED BEHAVIOR | | | | ==================================================================================== | | | | Legacy Reynolds formulation is enabled in pump characteristic 'dp_tau_centrifugal'. | | | | This behavior is DEPRECATED and will be REMOVED in v2.0. | | | | Action required: Set useLegacyReynolds = false to enable the corrected formulation. | | | | Component: Pump_dp_tau_centrifugal_DesignPoint.legacyPump2 | | | | Remark: Use OMEdit or Dymola 2025x and later to avoid repeated warnings. | | | | ==================================================================================== LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/TurboComponent/dp_tau_centrifugal.mo:99:3-110:28:writable] | | | | | | | | ==================================================================================== | | | | ThermoFluidStream WARNING – DEPRECATED BEHAVIOR | | | | ==================================================================================== | | | | Legacy Reynolds formulation is enabled in pump characteristic 'dp_tau_centrifugal'. | | | | This behavior is DEPRECATED and will be REMOVED in v2.0. | | | | Action required: Set useLegacyReynolds = false to enable the corrected formulation. | | | | Component: Pump_dp_tau_centrifugal_DesignPoint.legacyPump1 | | | | Remark: Use OMEdit or Dymola 2025x and later to avoid repeated warnings. | | | | ==================================================================================== LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/TurboComponent/dp_tau_centrifugal.mo:99:3-110:28:writable] | | | | | | | | ==================================================================================== | | | | ThermoFluidStream WARNING – DEPRECATED BEHAVIOR | | | | ==================================================================================== | | | | Legacy Reynolds formulation is enabled in pump characteristic 'dp_tau_centrifugal'. | | | | This behavior is DEPRECATED and will be REMOVED in v2.0. | | | | Action required: Set useLegacyReynolds = false to enable the corrected formulation. | | | | Component: Pump_dp_tau_centrifugal_DesignPoint.legacyPump | | | | Remark: Use OMEdit or Dymola 2025x and later to avoid repeated warnings. | | | | ==================================================================================== LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0144341s reading init.xml | | | | | | 0.000908655s reading info.xml | | | | | | 0.0230432s [ 7.0%] pre-initialization | | | | | | 0.000861756s [ 0.3%] initialization | | | | | | 0.000204614s [ 0.1%] steps | | | | | | 0.000947792s [ 0.3%] solver (excl. callbacks) | | | | | | 0.00426187s [ 1.3%] creating output-file | | | | | | 3.1746e-05s [ 0.0%] event-handling | | | | | | 0.00661385s [ 2.0%] overhead | | | | | | 0.291376s [ 89.0%] simulation | | | | | | 0.327341s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 306 steps taken | | | | | | 385 calls of functionODE | | | | | | 37 evaluations of jacobian | | | | | | 8 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0113782s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.