Environment - simulationEnvironment: startTime=0 stopTime=25 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.025 Regular simulation: ./ThermofluidStream_ThermofluidStream.Examples.WaterHammer -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolume.mo:114:3-114:109:writable] | | | | The following assertion has been violated at time 7.425000 | | | | ((checkValve.inlet.m_flow > reservoir.m_flow_assert)) --> "Negative mass flow rate at Volume inlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00477721s reading init.xml | | | | | | 0.000320411s reading info.xml | | | | | | 0.000428614s [ 1.2%] pre-initialization | | | | | | 0.000159099s [ 0.4%] initialization | | | | | | 3.617e-06s [ 0.0%] steps | | | | | | 0.007517s [ 20.2%] solver (excl. callbacks) | | | | | | 0.000495844s [ 1.3%] creating output-file | | | | | | 0.00119498s [ 3.2%] event-handling | | | | | | 0.00147876s [ 4.0%] overhead | | | | | | 0.0259873s [ 69.7%] simulation | | | | | | 0.0372652s [100.0%] total | | | | | events | | | | | | 50 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 9858 steps taken | | | | | | 17342 calls of functionODE | | | | | | 2077 evaluations of jacobian | | | | | | 647 error test failures | | | | | | 77 convergence test failures | | | | | | 0.00727501s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.