Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.001 Regular simulation: ./ThermofluidStream_ThermofluidStream.Boundaries.Tests.Volumes -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolume.mo:115:3-115:112:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((flowResistance10.inlet.m_flow > volume1.m_flow_assert)) --> "Positive mass flow rate at Volume outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolume.mo:114:3-114:109:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((flowResistance11.inlet.m_flow > volume1.m_flow_assert)) --> "Negative mass flow rate at Volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolumeN.mo:109:3-109:112:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((flowResistance14.inlet.m_flow > volumeMix3.m_flow_assert)) --> "Positive mass flow rate at volume outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolumeN.mo:107:5-107:114:writable] | | | | The following assertion has been violated at time 0.003000 | | | | ((flowResistance13.inlet.m_flow > volumeMix3.m_flow_assert)) --> "Negative mass flow rate at volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolumeN.mo:107:5-107:114:writable] | | | | The following assertion has been violated at time 0.020000 | | | | ((flowResistance12.inlet.m_flow > volumeMix3.m_flow_assert)) --> "Negative mass flow rate at volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolume.mo:114:3-114:109:writable] | | | | The following assertion has been violated at time 0.053000 | | | | ((flowResistance7.inlet.m_flow > heatportVolume1.m_flow_assert)) --> "Negative mass flow rate at Volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/Internal/PartialVolume.mo:115:3-115:112:writable] | | | | The following assertion has been violated at time 0.162000 | | | | ((flowResistance9.inlet.m_flow > heatportVolume2.m_flow_assert)) --> "Positive mass flow rate at Volume outlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0237876s reading init.xml | | | | | | 0.00186435s reading info.xml | | | | | | 0.00144687s [ 0.6%] pre-initialization | | | | | | 0.00050663s [ 0.2%] initialization | | | | | | 0.000140474s [ 0.1%] steps | | | | | | 0.00941386s [ 3.7%] solver (excl. callbacks) | | | | | | 0.00238269s [ 0.9%] creating output-file | | | | | | 3.8947e-05s [ 0.0%] event-handling | | | | | | 0.0106528s [ 4.1%] overhead | | | | | | 0.232541s [ 90.4%] simulation | | | | | | 0.257124s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2260 steps taken | | | | | | 3091 calls of functionODE | | | | | | 99 evaluations of jacobian | | | | | | 36 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0280537s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.