Environment - simulationEnvironment:
startTime=0
stopTime=1000
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.4
Regular simulation: ./ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_STDOUT        | warning | While solving non-linear system an assertion failed during initialization.
|                 | |       | | The non-linear solver tries to solve the problem that could take some time.
|                 | |       | | It could help to provide better start-values for the iteration variables.
|                 | |       | | For more information simulate with -lv LOG_NLS_V
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/DynamicCentrifugalPump.mo:46:3-46:43:writable]
|                 | |       | The following assertion has been violated at time 0.000000
|                 | |       | ((DynamicCentrifugalPump1.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= DynamicCentrifugalPump1.hn, has value: -2.75592e-56"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
DASKR--  AT T (=R1) AND STEPSIZE H (=R2) THE                                    
      In above,  R1 =   5.0761192151054E-03   R2 =   2.5228850770741E-16
DASKR--  NONLINEAR SYSTEM SOLVER COULD NOT CONVERGE                             
DASKR--  BECAUSE IRES WAS EQUAL TO MINUS ONE                                    
LOG_STDOUT        | warning | A Modelica assert prevents the integrator to continue. For more information use -lv LOG_SOLVER
LOG_STDOUT        | warning | can't continue. time = 0.005076
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/Common.mo:132:5-132:63:writable]
|                 | |       | The following assertion has been violated at time 0.005076
|                 | |       | ((volumeA.pro.x >= 0.0 and volumeA.pro.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= volumeA.pro.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/Common.mo:132:5-132:63:writable]
|                 | |       | The following assertion has been violated at time 0.005076
|                 | |       | ((DynamicCentrifugalPump1.pro.x >= 0.0 and DynamicCentrifugalPump1.pro.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= DynamicCentrifugalPump1.pro.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/Common.mo:132:5-132:63:writable]
|                 | |       | The following assertion has been violated at time 0.005076
|                 | |       | ((dynamicReliefValve.pro.x >= 0.0 and dynamicReliefValve.pro.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= dynamicReliefValve.pro.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/Common.mo:132:5-132:63:writable]
|                 | |       | The following assertion has been violated at time 0.005076
|                 | |       | ((Valve.pro.x >= 0.0 and Valve.pro.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= Valve.pro.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | The following assertion has been violated at time 0.005076
|                 | |       | (($cse1.x >= 0.0 and $cse1.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= $cse1.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | The following assertion has been violated at time 0.005076
|                 | |       | (($cse12.x >= 0.0 and $cse12.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= $cse12.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | The following assertion has been violated at time 0.005076
|                 | |       | (($cse14.x >= 0.0 and $cse14.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= $cse14.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | The following assertion has been violated at time 0.005076
|                 | |       | (($cse15.x >= 0.0 and $cse15.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= $cse15.x <= 1.0, has value: -1"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Connectors.mo:88:5-89:45:writable]
|                 | |       | The following assertion has been violated at time 0.005076
|                 | |       | ((Tank.Cs2.P >= 0.0)) --> "Variable violating min constraint: 0.0 <= Tank.Cs2.P, has value: -3.98028e+06"
LOG_STDOUT        | info    | model terminate | Integrator failed. | Simulation terminated at time 0.00507612
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |   0.00745484s          reading init.xml
|                 | |       | | |  0.000525435s          reading info.xml
|                 | |       | | |   8.8055e-05s [  0.0%] pre-initialization
|                 | |       | | |    0.0151008s [  2.0%] initialization
|                 | |       | | |     0.223185s [ 29.8%] steps
|                 | |       | | |  0.000827237s [  0.1%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |     0.157426s [ 21.1%] event-handling
|                 | |       | | |   5.0024e-05s [  0.0%] overhead
|                 | |       | | |     0.351037s [ 46.9%] simulation
|                 | |       | | |     0.747715s [100.0%] total
|                 | |       | | events
|                 | |       | | |     3 state events
|                 | |       | | |     1 time events
|                 | |       | | solver: dassl
|                 | |       | | |   206 steps taken
|                 | |       | | |   305 calls of functionODE
|                 | |       | | |   111 evaluations of jacobian
|                 | |       | | |     6 error test failures
|                 | |       | | |    33 convergence test failures
|                 | |       | | | 0.381149s time of jacobian evaluation