Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.conf.json
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8585/0.8585, allocations: 152.6 MB / 171.4 MB, free: 5.992 MB / 142.1 MB
"
[Timeout remaining time 179]
Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo)
Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10")
translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10") [Timeout 660]
"Notification: Performance of FrontEnd - loaded program: time 0.0006896/0.0006896, allocations: 19.91 kB / 248.5 MB, free: 5.633 MB / 206.1 MB
Notification: Performance of FrontEnd - Absyn->SCode: time 0.1776/0.1783, allocations: 33.06 MB / 281.6 MB, free: 3.727 MB / 222.1 MB
Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica.
Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica.
Notification: Automatically loaded package Modelica 4.0.0 due to usage.
Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10): time 1.552/1.73, allocations: 303 MB / 0.5708 GB, free: 4.082 MB / 478.1 MB
Notification: Performance of NFInst.instExpressions: time 0.2661/1.996, allocations: 35.45 MB / 0.6054 GB, free: 4.59 MB / 478.1 MB
Notification: Performance of NFInst.updateImplicitVariability: time 0.000314/1.996, allocations: 5.25 kB / 0.6054 GB, free: 4.59 MB / 478.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
Notification: Performance of NFTyping.typeComponents: time 0.0004366/1.997, allocations: 197.4 kB / 0.6056 GB, free: 4.484 MB / 478.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert.
Notification: Performance of FrontEnd: time 7.485e-05/1.997, allocations: 35.75 kB / 0.6057 GB, free: 4.473 MB / 478.1 MB
"
[Timeout remaining time 658]
[Calling sys.exit(0), Time elapsed: 3.521624870598316]
Failed to read output from testmodel.py, exit status != 0:
2.153816116042435 2.165932511 -1.0
Calling exit ...
<OMPython.OMCSessionZMQ object at 0x7f14593bd7b0>