Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump.conf.json
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8457/0.8457, allocations: 152.6 MB / 171.4 MB, free: 6.004 MB / 142.1 MB
"
[Timeout remaining time 179]
Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo)
Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump")
translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump") [Timeout 660]
"Notification: Performance of FrontEnd - loaded program: time 0.0007678/0.0007678, allocations: 15.97 kB / 248.5 MB, free: 5.652 MB / 206.1 MB
Notification: Performance of FrontEnd - Absyn->SCode: time 0.2081/0.2089, allocations: 33.05 MB / 281.6 MB, free: 3.57 MB / 222.1 MB
Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica.
Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica.
Notification: Automatically loaded package Modelica 4.0.0 due to usage.
Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump): time 1.557/1.765, allocations: 302.4 MB / 0.5703 GB, free: 4.375 MB / 478.1 MB
Notification: Performance of NFInst.instExpressions: time 0.2558/2.021, allocations: 31.94 MB / 0.6015 GB, free: 7.246 MB / 478.1 MB
Notification: Performance of NFInst.updateImplicitVariability: time 0.0002776/2.022, allocations: 3.938 kB / 0.6015 GB, free: 7.246 MB / 478.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:71:3-72:53:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:73:3-74:53:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:78:3-79:55:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:80:3-81:51:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/ElectroMechanics/BoundaryConditions/SourceAngularVelocity.mo:11:3-15:24:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
Notification: Performance of NFTyping.typeComponents: time 0.0004592/2.022, allocations: 187.2 kB / 0.6016 GB, free: 7.156 MB / 478.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert.
Notification: Performance of FrontEnd: time 6.833e-05/2.022, allocations: 40.41 kB / 0.6017 GB, free: 7.141 MB / 478.1 MB
"
[Timeout remaining time 658]
[Calling sys.exit(0), Time elapsed: 3.5277108680456877]
Failed to read output from testmodel.py, exit status != 0:
2.173350017517805 2.185974695 -1.0
Calling exit ...
<OMPython.OMCSessionZMQ object at 0x7f04e03397b0>