Environment - simulationEnvironment:
startTime=0
stopTime=350
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.14
Regular simulation: ./ScalableTestSuite_noopt_ScalableTestSuite.Thermal.HeatConduction.Verification.OneDHeatTransferTT_Check  -abortSlowSimulation -alarm=300  -emit_protected -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |   0.00632457s          reading init.xml
|                 | |       | | |  0.000360155s          reading info.xml
|                 | |       | | |    0.0103294s [ 31.5%] pre-initialization
|                 | |       | | |  0.000155752s [  0.5%] initialization
|                 | |       | | |      5.3e-06s [  0.0%] steps
|                 | |       | | |   0.00113487s [  3.5%] solver (excl. callbacks)
|                 | |       | | |   0.00693819s [ 21.2%] creating output-file
|                 | |       | | | -3.25578e-21s [ -0.0%] event-handling
|                 | |       | | |  0.000285496s [  0.9%] overhead
|                 | |       | | |    0.0138967s [ 42.4%] simulation
|                 | |       | | |     0.032781s [100.0%] total
|                 | |       | | events
|                 | |       | | |     0 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   140 steps taken
|                 | |       | | |   164 calls of functionODE
|                 | |       | | |    19 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.000195582s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.