Environment - simulationEnvironment:
startTime=0
stopTime=4e-06
tolerance=1e-08
numberOfIntervals=1999
stepSize=2.001e-09
Regular simulation: ./ScalableTestSuite_noopt_ScalableTestSuite.Electrical.TransmissionLine.ScaledExperiments.TransmissionLineEquations_N_20  -s=ida -abortSlowSimulation -alarm=300  -emit_protected -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |   0.00132334s          reading init.xml
|                 | |       | | |  0.000105708s          reading info.xml
|                 | |       | | |  0.000403106s [  4.1%] pre-initialization
|                 | |       | | |   9.0189e-05s [  0.9%] initialization
|                 | |       | | |    4.398e-06s [  0.0%] steps
|                 | |       | | |   0.00382736s [ 39.0%] solver (excl. callbacks)
|                 | |       | | |   0.00102381s [ 10.4%] creating output-file
|                 | |       | | |   1.9148e-05s [  0.2%] event-handling
|                 | |       | | |  0.000162805s [  1.7%] overhead
|                 | |       | | |   0.00427814s [ 43.6%] simulation
|                 | |       | | |   0.00980896s [100.0%] total
|                 | |       | | events
|                 | |       | | |     1 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: ida
|                 | |       | | |  1495 steps taken
|                 | |       | | |  1505 calls of functionODE
|                 | |       | | |    41 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.000303225s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.