Environment - simulationEnvironment:
startTime=0
stopTime=4e-06
tolerance=1e-08
numberOfIntervals=1999
stepSize=2.001e-09
Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Electrical.TransmissionLine.ScaledExperiments.TransmissionLineEquations_N_1280  -s=ida -abortSlowSimulation -alarm=300  -emit_protected -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0666458s          reading init.xml
|                 | |       | | |    0.0040779s          reading info.xml
|                 | |       | | |   0.00114269s [  0.0%] pre-initialization
|                 | |       | | |  0.000676379s [  0.0%] initialization
|                 | |       | | |   0.00430715s [  0.1%] steps
|                 | |       | | |      3.94463s [ 48.1%] solver (excl. callbacks)
|                 | |       | | |    0.0526772s [  0.6%] creating output-file
|                 | |       | | |  0.000690106s [  0.0%] event-handling
|                 | |       | | |   0.00116558s [  0.0%] overhead
|                 | |       | | |      4.20204s [ 51.2%] simulation
|                 | |       | | |      8.20733s [100.0%] total
|                 | |       | | events
|                 | |       | | |     1 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: ida
|                 | |       | | | 33087 steps taken
|                 | |       | | | 41245 calls of functionODE
|                 | |       | | |    36 evaluations of jacobian
|                 | |       | | |     2 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.0205511s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.