Environment - simulationEnvironment:
startTime=0
stopTime=360000
tolerance=1e-06
numberOfIntervals=2500
stepSize=144
Regular simulation: ./PowerSysPro_PowerSysPro.Examples.UsingBatteries.OneBatteryOneLineOneLoad  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1/package.mo:72:7-72:91:writable]
|                 | |       | The following assertion has been violated at time 50633.393235
|                 | |       | ((bat.battery.integrator.q >= bat.minCharging)) --> ">>> Battery OneBatteryOneLineOneLoad.bat is empty"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1/package.mo:72:7-72:91:writable]
|                 | |       | The following assertion has been violated at time 50633.393235
|                 | |       | ((bat.battery.integrator.q >= bat.minCharging)) --> ">>> Battery OneBatteryOneLineOneLoad.bat is empty"
LOG_ASSERT        | info    | Found event, previous asserts are ignored.
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1/package.mo:72:7-72:91:writable]
|                 | |       | The following assertion has been violated at time 50688.000000
|                 | |       | ((bat.battery.integrator.q >= bat.minCharging)) --> ">>> Battery OneBatteryOneLineOneLoad.bat is empty"
LOG_ASSERT        | error   | No event found, but assert was triggered. Throwing now!