Environment - simulationEnvironment:
startTime=0
stopTime=10
tolerance=1e-06
numberOfIntervals=50000
stepSize=0.0002
Regular simulation: ./Modelica_trunk_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse.ThyristorBridge2mPulse_RLV_Characteristic  -abortSlowSimulation -alarm=480  -emit_protected -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |   0.00849322s          reading init.xml
|                 | |       | | |  0.000674805s          reading info.xml
|                 | |       | | |  0.000855445s [  0.0%] pre-initialization
|                 | |       | | |  0.000238146s [  0.0%] initialization
|                 | |       | | |     5.32e-06s [  0.0%] steps
|                 | |       | | |     0.309576s [  6.7%] solver (excl. callbacks)
|                 | |       | | |    0.0606126s [  1.3%] creating output-file
|                 | |       | | |      2.31565s [ 49.8%] event-handling
|                 | |       | | |    0.0152023s [  0.3%] overhead
|                 | |       | | |      1.94682s [ 41.9%] simulation
|                 | |       | | |      4.64897s [100.0%] total
|                 | |       | | events
|                 | |       | | |  9999 state events
|                 | |       | | |  3000 time events
|                 | |       | | solver: dassl
|                 | |       | | | 324741 steps taken
|                 | |       | | | 404774 calls of functionODE
|                 | |       | | | 160364 evaluations of jacobian
|                 | |       | | |  5165 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.468357s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.