Environment - simulationEnvironment:
startTime=0
stopTime=0.1
tolerance=1e-06
numberOfIntervals=1000
stepSize=0.0001
Regular simulation: ./Modelica_4.0.0_Modelica.Electrical.Machines.Examples.Transformers.Rectifier6pulse  -abortSlowSimulation -alarm=480  -emit_protected -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0156036s          reading init.xml
|                 | |       | | |   0.00120773s          reading info.xml
|                 | |       | | |  0.000510928s [  0.3%] pre-initialization
|                 | |       | | |  0.000402715s [  0.3%] initialization
|                 | |       | | |   1.9146e-05s [  0.0%] steps
|                 | |       | | |   0.00658658s [  4.5%] solver (excl. callbacks)
|                 | |       | | |  0.000813414s [  0.6%] creating output-file
|                 | |       | | |    0.0549157s [ 37.4%] event-handling
|                 | |       | | |   0.00104816s [  0.7%] overhead
|                 | |       | | |    0.0824202s [ 56.2%] simulation
|                 | |       | | |     0.146717s [100.0%] total
|                 | |       | | events
|                 | |       | | |    60 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |  3800 steps taken
|                 | |       | | |  5134 calls of functionODE
|                 | |       | | |  1111 evaluations of jacobian
|                 | |       | | |    61 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.0305631s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.