Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr LibRAS_LibRAS.Examples.TinyRAS.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001337/0.001337, allocations: 113.6 kB / 19.74 MB, free: 1.992 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001735/0.001735, allocations: 195.8 kB / 23.03 MB, free: 5.004 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.642/1.642, allocations: 207.6 MB / 233.8 MB, free: 10.01 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo): time 0.03025/0.03025, allocations: 5.571 MB / 291.6 MB, free: 280 kB / 222.1 MB " [Timeout remaining time 180] Using package LibRAS with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(LibRAS.Examples.TinyRAS,tolerance=0.0001,outputFormat="empty",numberOfIntervals=2880,variableFilter="",fileNamePrefix="LibRAS_LibRAS.Examples.TinyRAS") translateModel(LibRAS.Examples.TinyRAS,tolerance=0.0001,outputFormat="empty",numberOfIntervals=2880,variableFilter="",fileNamePrefix="LibRAS_LibRAS.Examples.TinyRAS") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: LibRAS requested package Modelica of version 3.2.2. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002219/0.002219, allocations: 77.06 kB / 408.2 MB, free: 48.49 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09747/0.09968, allocations: 50.47 MB / 458.7 MB, free: 388 kB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/Tanks/FishTank.mo:26:33-26:43:writable] Error: Modified element unit not found in class Integer. Notification: Performance of FrontEnd: time 0.05004/0.1497, allocations: 44.06 MB / 0.4909 GB, free: 4.145 MB / 366.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.8428978519514203] Failed to read output from testmodel.py, exit status != 0: 0.15731509029865265 0.17166249800000002 -1.0 Calling exit ... <OMPython.OMCSessionZMQ object at 0x7fe6362397b0>