Environment - simulationEnvironment:
startTime=0
stopTime=3600
tolerance=1e-06
numberOfIntervals=2500
stepSize=1.44
Regular simulation: ./IDEAS_IDEAS.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |   0.00587104s          reading init.xml
|                 | |       | | |  0.000471584s          reading info.xml
|                 | |       | | |   6.6966e-05s [  0.7%] pre-initialization
|                 | |       | | |  0.000223018s [  2.5%] initialization
|                 | |       | | |    1.873e-06s [  0.0%] steps
|                 | |       | | |    2.893e-06s [  0.0%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   6.0343e-05s [  0.7%] event-handling
|                 | |       | | |   0.00276979s [ 30.7%] overhead
|                 | |       | | |   0.00588412s [ 65.3%] simulation
|                 | |       | | |     0.009009s [100.0%] total
|                 | |       | | events
|                 | |       | | |     2 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: euler
|                 | |       | | |  5046 steps taken
|                 | |       | | |  5046 calls of functionODE
|                 | |       | | |     0 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.