Environment - simulationEnvironment:
startTime=1e+07
stopTime=1.1e+07
tolerance=1e-06
numberOfIntervals=2500
stepSize=400
Regular simulation: ./IDEAS_IDEAS.Examples.Tutorial.Example6  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable]
|                 | |       | The following assertion has been violated during initialization at time 10000000.000000
|                 | |       | ((pumpSec.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the
|                 | |       |              default pressure curve.
|                 | |       |              This leads to approximate calculations of the electrical power
|                 | |       |              consumption. Add the correct pressure curve in the record per
|                 | |       |              to obtain an accurate computation.
|                 | |       |              Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable]
|                 | |       | The following assertion has been violated during initialization at time 10000000.000000
|                 | |       | ((pumpPrim.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the
|                 | |       |              default pressure curve.
|                 | |       |              This leads to approximate calculations of the electrical power
|                 | |       |              consumption. Add the correct pressure curve in the record per
|                 | |       |              to obtain an accurate computation.
|                 | |       |              Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning."
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |     0.237565s          reading init.xml
|                 | |       | | |    0.0143557s          reading info.xml
|                 | |       | | |   0.00042147s [  0.0%] pre-initialization
|                 | |       | | |    0.0316405s [  0.1%] initialization
|                 | |       | | |   0.00107687s [  0.0%] steps
|                 | |       | | |      2.39157s [  4.5%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |      8.61602s [ 16.4%] event-handling
|                 | |       | | |     0.135822s [  0.3%] overhead
|                 | |       | | |      41.4838s [ 78.8%] simulation
|                 | |       | | |      52.6603s [100.0%] total
|                 | |       | | events
|                 | |       | | |  3858 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | | 127649 steps taken
|                 | |       | | | 175546 calls of functionODE
|                 | |       | | | 49709 evaluations of jacobian
|                 | |       | | |  6334 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 33.6315s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.