Environment - simulationEnvironment: startTime=0 stopTime=500000 tolerance=1e-06 numberOfIntervals=2500 stepSize=200 Regular simulation: ./IDEAS_IDEAS.Buildings.Components.BaseClasses.ConductiveHeatTransfer.Examples.MultiLayerRamp -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00372734s reading init.xml | | | | | | 0.000252734s reading info.xml | | | | | | 8.7043e-05s [ 2.1%] pre-initialization | | | | | | 0.000125976s [ 3.0%] initialization | | | | | | 9.92e-07s [ 0.0%] steps | | | | | | 0.000616032s [ 14.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000226854s [ 5.4%] event-handling | | | | | | 0.000471988s [ 11.2%] overhead | | | | | | 0.00270372s [ 63.9%] simulation | | | | | | 0.00423261s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 266 steps taken | | | | | | 349 calls of functionODE | | | | | | 64 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 0 convergence test failures | | | | | | 9.64e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.