Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.GridForming.GridForming.conf.json
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001951/0.001951, allocations: 109.7 kB / 19.71 MB, free: 2.18 MB / 14.72 MB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.002464/0.002464, allocations: 188.3 kB / 22.99 MB, free: 5.043 MB / 14.72 MB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.524/1.524, allocations: 207.6 MB / 233.8 MB, free: 10.02 MB / 190.1 MB
"
[Timeout remaining time 178]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/package.mo): time 0.6323/0.6323, allocations: 108.3 MB / 394.4 MB, free: 19.24 MB / 318.1 MB
"
[Timeout remaining time 179]
Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/package.mo)
Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo)
Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo)
Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo)
Ignoring simflag  -noemit -emit_protected=() since it seems broken on HelloWorld
Running command: translateModel(Dynawo.Examples.GridForming.GridForming,tolerance=1e-06,outputFormat="mat",numberOfIntervals=500,variableFilter="time|Conv1000.IConvPu|Conv250.IConvPu|Conv500.IConvPu|Droop.omegaPu|Matching.omegaPu|dVOC.omegaPu|Conv1000.omegaPu|Conv250.omegaPu|Conv500.omegaPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.GridForming.GridForming")
translateModel(Dynawo.Examples.GridForming.GridForming,tolerance=1e-06,outputFormat="mat",numberOfIntervals=500,variableFilter="time|Conv1000.IConvPu|Conv250.IConvPu|Conv500.IConvPu|Droop.omegaPu|Matching.omegaPu|dVOC.omegaPu|Conv1000.omegaPu|Conv250.omegaPu|Conv500.omegaPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.GridForming.GridForming") [Timeout 660]
"Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Performance of FrontEnd - loaded program: time 0.002234/0.002234, allocations: 68.98 kB / 0.5564 GB, free: 51.88 MB / 462.1 MB
Notification: Performance of FrontEnd - Absyn->SCode: time 0.1494/0.1516, allocations: 77.08 MB / 0.6316 GB, free: 14.02 MB / 478.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Types.mo:49:35-49:96:writable] Warning: Prefix 'flow' used outside connector declaration.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Types.mo:50:35-50:101:writable] Warning: Prefix 'flow' used outside connector declaration.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/Load_INIT.mo:25:3-25:132:writable] Warning: Prefix 'flow' used outside connector declaration.
Notification: Performance of NFInst.instantiate(Dynawo.Examples.GridForming.GridForming): time 0.02114/0.1728, allocations: 17.04 MB / 0.6483 GB, free: 12.89 MB / 494.1 MB
Notification: Performance of NFInst.instExpressions: time 0.01471/0.1875, allocations: 6.219 MB / 0.6544 GB, free: 6.648 MB / 494.1 MB
Notification: Performance of NFInst.updateImplicitVariability: time 0.004864/0.1923, allocations: 63.69 kB / 0.6544 GB, free: 6.586 MB / 494.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Events/NodeFault.mo:24:3-24:107:writable] Warning: Connector nodeFault is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
Notification: Performance of NFTyping.typeComponents: time 0.003437/0.1958, allocations: 0.7295 MB / 0.6551 GB, free: 5.863 MB / 494.1 MB
Notification: Performance of NFTyping.typeBindings: time 0.005914/0.2017, allocations: 1.051 MB / 0.6562 GB, free: 4.805 MB / 494.1 MB
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:494:3-494:50:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:497:3-497:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:499:3-499:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:501:3-501:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:503:3-503:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:505:3-505:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:507:3-507:41:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:508:3-508:41:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:510:3-510:41:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:511:3-511:41:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:513:3-513:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/GridForming/GridForming.mo:514:3-514:42:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context.
[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context.
Notification: Performance of NFTyping.typeClassSections: time 0.006954/0.2087, allocations: 2.631 MB / 0.6587 GB, free: 2.176 MB / 494.1 MB
Notification: Performance of NFFlatten.flatten: time 0.0103/0.219, allocations: 5.867 MB / 0.6645 GB, free: 12.29 MB / 0.4981 GB
Notification: Performance of NFFlatten.resolveConnections: time 0.003638/0.2226, allocations: 1.47 MB / 0.6659 GB, free: 10.75 MB / 0.4981 GB
Notification: Performance of NFEvalConstants.evaluate: time 0.004089/0.2267, allocations: 2.261 MB / 0.6681 GB, free: 8.48 MB / 0.4981 GB
Notification: Performance of NFSimplifyModel.simplify: time 0.004536/0.2312, allocations: 2.699 MB / 0.6707 GB, free: 5.77 MB / 0.4981 GB
Notification: Performance of NFPackage.collectConstants: time 0.002238/0.2335, allocations: 0.5781 MB / 0.6713 GB, free: 5.191 MB / 0.4981 GB
Notification: Performance of NFFlatten.collectFunctions: time 0.002209/0.2357, allocations: 0.746 MB / 0.672 GB, free: 4.445 MB / 0.4981 GB
Notification: Performance of NFScalarize.scalarize: time 0.001482/0.2371, allocations: 1.207 MB / 0.6732 GB, free: 3.234 MB / 0.4981 GB
Notification: Performance of NFVerifyModel.verify: time 0.003642/0.2408, allocations: 2.526 MB / 0.6757 GB, free: 0.6953 MB / 0.4981 GB
Notification: Performance of NFConvertDAE.convert: time 0.01032/0.2511, allocations: 6.68 MB / 0.6822 GB, free: 9.988 MB / 0.5137 GB
Notification: Performance of FrontEnd - DAE generated: time 6.072e-06/0.2511, allocations: 4 kB / 0.6822 GB, free: 9.984 MB / 0.5137 GB
Notification: Performance of FrontEnd: time 1.804e-06/0.2511, allocations: 4 kB / 0.6822 GB, free: 9.98 MB / 0.5137 GB
Notification: Performance of Transformations before backend: time 0.0002125/0.2513, allocations: 0 / 0.6822 GB, free: 9.98 MB / 0.5137 GB
Notification: Model statistics after passing the front-end and creating the data structures used by the back-end:
 * Number of equations: 932
 * Number of variables: 932
Notification: Performance of Generate backend data structure: time 0.02094/0.2723, allocations: 6.356 MB / 0.6884 GB, free: 3.496 MB / 0.5137 GB
Notification: Performance of prepare preOptimizeDAE: time 5.005e-05/0.2723, allocations: 8.75 kB / 0.6884 GB, free: 3.488 MB / 0.5137 GB
Notification: Performance of preOpt normalInlineFunction (simulation): time 0.006238/0.2785, allocations: 1.145 MB / 0.6895 GB, free: 2.34 MB / 0.5137 GB
Notification: Performance of preOpt evaluateParameters (simulation): time 0.005789/0.2843, allocations: 2.216 MB / 0.6917 GB, free: 80 kB / 0.5137 GB
Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0007419/0.2851, allocations: 0.6602 MB / 0.6923 GB, free: 15.35 MB / 0.5294 GB
Notification: Performance of preOpt expandDerOperator (simulation): time 0.001235/0.2863, allocations: 412.3 kB / 0.6927 GB, free: 14.95 MB / 0.5294 GB
Notification: Performance of preOpt clockPartitioning (simulation): time 0.01095/0.2973, allocations: 4.508 MB / 0.6971 GB, free: 10.19 MB / 0.5294 GB
Notification: Performance of preOpt findStateOrder (simulation): time 7.784e-05/0.2973, allocations: 15.88 kB / 0.6972 GB, free: 10.18 MB / 0.5294 GB
Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0004442/0.2978, allocations: 168 kB / 0.6973 GB, free: 10.01 MB / 0.5294 GB
Notification: Performance of preOpt inlineArrayEqn (simulation): time 9.621e-05/0.2979, allocations: 92 kB / 0.6974 GB, free: 9.922 MB / 0.5294 GB
Notification: Performance of preOpt removeEqualRHS (simulation): time 0.008409/0.3063, allocations: 3.345 MB / 0.7007 GB, free: 6.566 MB / 0.5294 GB
Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.04242/0.3487, allocations: 24.57 MB / 0.7247 GB, free: 12.31 MB / 0.5606 GB
Notification: Performance of preOpt comSubExp (simulation): time 0.009044/0.3578, allocations: 3.611 MB / 0.7282 GB, free: 8.633 MB / 0.5606 GB
Notification: Performance of preOpt resolveLoops (simulation): time 0.004695/0.3625, allocations: 1.972 MB / 0.7301 GB, free: 6.633 MB / 0.5606 GB
Notification: Performance of preOpt evalFunc (simulation): time 0.0004882/0.3629, allocations: 54.42 kB / 0.7302 GB, free: 6.578 MB / 0.5606 GB
Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.006282/0.3692, allocations: 2.585 MB / 0.7327 GB, free: 3.934 MB / 0.5606 GB
Notification: Performance of pre-optimization done (n=411): time 1.422e-05/0.3692, allocations: 0 / 0.7327 GB, free: 3.934 MB / 0.5606 GB
Notification: Performance of matching and sorting (n=411): time 0.03384/0.4031, allocations: 8.078 MB / 0.7406 GB, free: 11.79 MB / 0.5762 GB
Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002513/0.4033, allocations: 301.9 kB / 0.7409 GB, free: 11.43 MB / 0.5762 GB
Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.006323/0.4096, allocations: 2.795 MB / 0.7436 GB, free: 8.637 MB / 0.5762 GB
Notification: Performance of collectPreVariables (initialization): time 0.0012/0.4108, allocations: 129.7 kB / 0.7437 GB, free: 8.504 MB / 0.5762 GB
Notification: Performance of collectInitialEqns (initialization): time 0.002052/0.4129, allocations: 1.562 MB / 0.7453 GB, free: 6.926 MB / 0.5762 GB
Notification: Performance of collectInitialBindings (initialization): time 0.002975/0.4159, allocations: 1.488 MB / 0.7467 GB, free: 5.426 MB / 0.5762 GB
Notification: Performance of simplifyInitialFunctions (initialization): time 0.004531/0.4204, allocations: 1.164 MB / 0.7478 GB, free: 4.254 MB / 0.5762 GB
Notification: Performance of setup shared object (initialization): time 0.0001522/0.4206, allocations: 309 kB / 0.7481 GB, free: 3.949 MB / 0.5762 GB
Notification: Performance of preBalanceInitialSystem (initialization): time 0.006011/0.4266, allocations: 2.359 MB / 0.7504 GB, free: 1.586 MB / 0.5762 GB
Notification: Performance of partitionIndependentBlocks (initialization): time 0.006999/0.4336, allocations: 3.175 MB / 0.7535 GB, free: 14.18 MB / 0.5919 GB
Notification: Performance of analyzeInitialSystem (initialization): time 0.04257/0.4761, allocations: 13.93 MB / 0.7671 GB, free: 15.7 MB / 0.6075 GB
Notification: Performance of solveInitialSystemEqSystem (initialization): time 7.276e-05/0.4762, allocations: 8 kB / 0.7671 GB, free: 15.7 MB / 0.6075 GB
Notification: Performance of matching and sorting (n=892) (initialization): time 0.02979/0.506, allocations: 8.48 MB / 0.7754 GB, free: 7.133 MB / 0.6075 GB
Notification: Performance of prepare postOptimizeDAE: time 0.0003444/0.5063, allocations: 157.5 kB / 0.7756 GB, free: 6.973 MB / 0.6075 GB
Notification: Performance of postOpt simplifyComplexFunction (initialization): time 5.074e-05/0.5064, allocations: 20.09 kB / 0.7756 GB, free: 6.953 MB / 0.6075 GB
Notification: Performance of postOpt tearingSystem (initialization): time 0.3639/0.8703, allocations: 58.26 MB / 0.8325 GB, free: 98 MB / 0.6075 GB
Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01401/0.8843, allocations: 1.698 MB / 0.8342 GB, free: 96.7 MB / 0.6075 GB
Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0199/0.9042, allocations: 16.56 MB / 0.8503 GB, free: 82.9 MB / 0.6075 GB
Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.004194/0.9084, allocations: 0.5441 MB / 0.8509 GB, free: 82.66 MB / 0.6075 GB
Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0005225/0.9089, allocations: 239.2 kB / 0.8511 GB, free: 82.43 MB / 0.6075 GB
Warning: Assuming fixed start value for the following 48 variables:
         Line12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line12.State0 fixed = true )  \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Line13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line13.State0 fixed = true )  \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Line23.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23.State0 fixed = true )  \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Line23Bis1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23Bis1.State0 fixed = true )  \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Line23Bis2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23Bis2.State0 fixed = true )  \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Load.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load.State0 fixed = true )  \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Conv1000.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv1000.State0 fixed = true )  \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Conv500.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv500.State0 fixed = true )  \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Conv250.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv250.State0 fixed = true )  \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined)
         Droop.droopControl.firstOrder.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder.y_start fixed = true )  \"Connector of Real output signal\" type: Real
         Droop.droopControl.firstOrder1.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder1.y_start fixed = true )  \"Connector of Real output signal\" type: Real
         Droop.droopControl.firstOrder2.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder2.y_start fixed = true )  \"Connector of Real output signal\" type: Real
         Droop.droopControl.firstOrder3.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder3.y_start fixed = true )  \"Connector of Real output signal\" type: Real
         Conv250.running.value:DISCRETE(flow=false start = Conv250.Running0 fixed = true )  type: Boolean
         Conv250.udFilterPu:VARIABLE(flow=false start = Conv250.UdFilter0Pu fixed = true )  \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real
         Conv250.uqFilterPu:VARIABLE(flow=false start = Conv250.UqFilter0Pu fixed = true )  \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real
         Conv250.idConvPu:VARIABLE(flow=false start = Conv250.IdConv0Pu fixed = true )  \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv250.iqConvPu:VARIABLE(flow=false start = Conv250.IqConv0Pu fixed = true )  \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv250.idPccPu:VARIABLE(flow=false start = Conv250.IdPcc0Pu fixed = true )  \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv250.iqPccPu:VARIABLE(flow=false start = Conv250.IqPcc0Pu fixed = true )  \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv250.UdcSourcePu:VARIABLE(flow=false start = Droop.dCVoltageControl.UdcSource0Pu fixed = true )  \"DC voltage in pu (base UdcNom)\" type: Real
         dVOC.dispatchableVirtualOscillatorControl.UFilterRefRawPu:VARIABLE(start = dVOC.dispatchableVirtualOscillatorControl.UFilterRef0Pu unit = \"1\" fixed = true )  type: Real
         Conv500.running.value:DISCRETE(flow=false start = Conv500.Running0 fixed = true )  type: Boolean
         Conv500.udFilterPu:VARIABLE(flow=false start = Conv500.UdFilter0Pu fixed = true )  \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real
         Conv500.uqFilterPu:VARIABLE(flow=false start = Conv500.UqFilter0Pu fixed = true )  \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real
         Conv500.idConvPu:VARIABLE(flow=false start = Conv500.IdConv0Pu fixed = true )  \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv500.iqConvPu:VARIABLE(flow=false start = Conv500.IqConv0Pu fixed = true )  \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv500.idPccPu:VARIABLE(flow=false start = Conv500.IdPcc0Pu fixed = true )  \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv500.iqPccPu:VARIABLE(flow=false start = Conv500.IqPcc0Pu fixed = true )  \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv500.UdcSourcePu:VARIABLE(flow=false start = dVOC.dCVoltageControl.UdcSource0Pu fixed = true )  \"DC voltage in pu (base UdcNom)\" type: Real
         Conv1000.running.value:DISCRETE(flow=false start = Conv1000.Running0 fixed = true )  type: Boolean
         Conv1000.udFilterPu:VARIABLE(flow=false start = Conv1000.UdFilter0Pu fixed = true )  \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real
         Conv1000.uqFilterPu:VARIABLE(flow=false start = Conv1000.UqFilter0Pu fixed = true )  \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real
         Conv1000.idConvPu:VARIABLE(flow=false start = Conv1000.IdConv0Pu fixed = true )  \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv1000.iqConvPu:VARIABLE(flow=false start = Conv1000.IqConv0Pu fixed = true )  \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv1000.idPccPu:VARIABLE(flow=false start = Conv1000.IdPcc0Pu fixed = true )  \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv1000.iqPccPu:VARIABLE(flow=false start = Conv1000.IqPcc0Pu fixed = true )  \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real
         Conv1000.UdcSourcePu:VARIABLE(flow=false start = Matching.matchingControl.UdcSource0Pu fixed = true )  \"DC voltage in pu (base UdcNom)\" type: Real
         Line12.running.value:DISCRETE(flow=false start = Line12.Running0 fixed = true )  type: Boolean
         Line13.running.value:DISCRETE(flow=false start = Line13.Running0 fixed = true )  type: Boolean
         Line23.running.value:DISCRETE(flow=false start = Line23.Running0 fixed = true )  type: Boolean
         Line23Bis1.running.value:DISCRETE(flow=false start = Line23Bis1.Running0 fixed = true )  type: Boolean
         Line23Bis2.running.value:DISCRETE(flow=false start = Line23Bis2.Running0 fixed = true )  type: Boolean
         Load.running.value:DISCRETE(flow=false start = Load.Running0 fixed = true )  type: Boolean
         Fault.nodeFault.value:DISCRETE(flow=false start = false fixed = true )  type: Boolean
         Conv1000.IConv0Pu:VARIABLE(unit = \"1\" fixed = true )  \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real
         Conv500.IConv0Pu:VARIABLE(unit = \"1\" fixed = true )  \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real
         Conv250.IConv0Pu:VARIABLE(unit = \"1\" fixed = true )  \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real
Notification: Model statistics after passing the back-end for initialization:
 * Number of independent subsystems: 72
 * Number of states: 0 ()
 * Number of discrete variables: 107 ($PRE.Line12.state,Line12.state,$PRE.Line13.state,Line13.state,$PRE.Line23.state,Line23.state,$PRE.Line23Bis1.state,Line23Bis1.state,$PRE.Line23Bis2.state,Line23Bis2.state,$PRE.Load.state,Load.state,$whenCondition1,$whenCondition2,$PRE.Conv1000.state,Conv1000.converter.u,Conv1000.state,$PRE.Conv500.state,Conv500.converter.u,Conv500.state,$PRE.Conv250.state,Conv250.converter.u,Conv250.state,Conv1000.switchOffSignal3.value,Conv1000.switchOffSignal2.value,Conv1000.switchOffSignal1.value,Conv500.switchOffSignal3.value,Conv500.switchOffSignal2.value,Conv500.switchOffSignal1.value,Conv250.switchOffSignal3.value,Conv250.switchOffSignal2.value,Conv250.switchOffSignal1.value,Load.switchOffSignal2.value,Load.switchOffSignal1.value,Line23Bis2.switchOffSignal2.value,Line23Bis2.switchOffSignal1.value,Line23Bis1.switchOffSignal2.value,Line23Bis1.switchOffSignal1.value,Line23.switchOffSignal2.value,Line23.switchOffSignal1.value,Line13.switchOffSignal2.value,Line13.switchOffSignal1.value,Line12.switchOffSignal1.value,$PRE.Conv250.running.value,$PRE.Conv500.running.value,$PRE.Conv1000.running.value,$PRE.Line12.running.value,$PRE.Line13.running.value,$PRE.Line23.running.value,$PRE.Line23Bis1.running.value,$PRE.Line23Bis2.running.value,$PRE.Load.running.value,$PRE.Fault.nodeFault.value,Disconnection.y,Fault.nodeFault.value,Load.running.value,Line23Bis2.running.value,Line23Bis1.running.value,Line23.running.value,Line13.running.value,Line12.running.value,Conv1000.running.value,Conv500.running.value,Conv250.running.value,$whenCondition3,$whenCondition5,$whenCondition4,$whenCondition6,$whenCondition8,$whenCondition7,$whenCondition9,$whenCondition11,$whenCondition10,$whenCondition12,$whenCondition14,$whenCondition13,$whenCondition15,$whenCondition17,$whenCondition16,$whenCondition19,$whenCondition18,$whenCondition21,$whenCondition20,$whenCondition22,$whenCondition24,$whenCondition23,$whenCondition25,$whenCondition27,$whenCondition26,$whenCondition28,$whenCondition30,$whenCondition29,Matching.matchingControl.integrator.local_reset,Matching.voltageLoop.integratorq.local_reset,Matching.voltageLoop.integratord.local_reset,Matching.currentLoop.integratorq.local_reset,Matching.currentLoop.integratord.local_reset,dVOC.dispatchableVirtualOscillatorControl.integrator.local_reset,dVOC.voltageLoop.integratorq.local_reset,dVOC.voltageLoop.integratord.local_reset,dVOC.currentLoop.integratorq.local_reset,dVOC.currentLoop.integratord.local_reset,Droop.droopControl.integrator.local_reset,Droop.voltageLoop.integratorq.local_reset,Droop.voltageLoop.integratord.local_reset,Droop.currentLoop.integratorq.local_reset,Droop.currentLoop.integratord.local_reset)
 * Number of discrete states: 0 ()
 * Number of clocked states: 0 ()
 * Top-level inputs: 0
Notification: Strong component statistics for initialization (726):
 * Single equations (assignments): 716
 * Array equations: 0
 * Algorithm blocks: 0
 * Record equations: 0
 * When equations: 0
 * If-equations: 0
 * Equation systems (not torn): 3
 * Torn equation systems: 7
 * Mixed (continuous/discrete) equation systems: 0
Notification: Equation system details (not torn):
 * Constant Jacobian (size): 0 systems
 * Linear Jacobian (size,density): 3 systems
   {(2,100.0%), (2,100.0%), (2,100.0%)}
 * Non-linear Jacobian (size): 0 systems
 * Without analytic Jacobian (size): 0 systems
Notification: Torn system details for strict tearing set:
 * Linear torn systems (#iteration vars, #inner vars, density): 4 systems
   {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)}
 * Non-linear torn systems (#iteration vars, #inner vars): 3 systems
   {(24,10), (1,1), (12,7)}
Notification: Performance of prepare postOptimizeDAE: time 0.002043/0.911, allocations: 1.036 MB / 0.8521 GB, free: 81.51 MB / 0.6075 GB
Notification: Performance of postOpt lateInlineFunction (simulation): time 0.0006592/0.9116, allocations: 418.7 kB / 0.8525 GB, free: 81.32 MB / 0.6075 GB
Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01347/0.9251, allocations: 5.593 MB / 0.858 GB, free: 76.63 MB / 0.6075 GB
Notification: Performance of postOpt inlineArrayEqn (simulation): time 2.487e-05/0.9251, allocations: 40 kB / 0.858 GB, free: 76.59 MB / 0.6075 GB
Notification: Performance of postOpt constantLinearSystem (simulation): time 1.814e-05/0.9251, allocations: 4 kB / 0.858 GB, free: 76.59 MB / 0.6075 GB
Notification: Performance of postOpt simplifysemiLinear (simulation): time 4.482e-05/0.9252, allocations: 24.81 kB / 0.858 GB, free: 76.58 MB / 0.6075 GB
Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02153/0.9467, allocations: 10.56 MB / 0.8683 GB, free: 68.29 MB / 0.6075 GB
Notification: Performance of postOpt simplifyComplexFunction (simulation): time 2.919e-05/0.9467, allocations: 4 kB / 0.8683 GB, free: 68.28 MB / 0.6075 GB
Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.01151/0.9582, allocations: 1.184 MB / 0.8695 GB, free: 67.23 MB / 0.6075 GB
Notification: Performance of postOpt tearingSystem (simulation): time 0.003009/0.9612, allocations: 1.294 MB / 0.8708 GB, free: 65.91 MB / 0.6075 GB
Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0008079/0.9621, allocations: 99.94 kB / 0.8709 GB, free: 65.82 MB / 0.6075 GB
Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.02612/0.9882, allocations: 40.8 MB / 0.9107 GB, free: 22.18 MB / 0.6075 GB
Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 3.727e-06/0.9882, allocations: 4.031 kB / 0.9107 GB, free: 22.18 MB / 0.6075 GB
Notification: Performance of postOpt symbolicJacobian (simulation): time 0.0225/1.011, allocations: 8.138 MB / 0.9187 GB, free: 13.93 MB / 0.6075 GB
Notification: Performance of postOpt removeConstants (simulation): time 0.001272/1.012, allocations: 461.7 kB / 0.9191 GB, free: 13.53 MB / 0.6075 GB
Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.00142/1.013, allocations: 99.94 kB / 0.9192 GB, free: 13.43 MB / 0.6075 GB
Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.003037/1.016, allocations: 111.9 kB / 0.9193 GB, free: 13.32 MB / 0.6075 GB
Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001194/1.018, allocations: 329.9 kB / 0.9196 GB, free: 13 MB / 0.6075 GB
Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0005656/1.018, allocations: 135.9 kB / 0.9197 GB, free: 12.86 MB / 0.6075 GB
Notification: Performance of sorting global known variables: time 0.002711/1.021, allocations: 1.729 MB / 0.9214 GB, free: 11.14 MB / 0.6075 GB
Notification: Performance of sort global known variables: time 1.1e-07/1.021, allocations: 0 / 0.9214 GB, free: 11.14 MB / 0.6075 GB
Notification: Performance of remove unused functions: time 0.004885/1.026, allocations: 1.382 MB / 0.9228 GB, free: 9.766 MB / 0.6075 GB
Notification: Model statistics after passing the back-end for simulation:
 * Number of independent subsystems: 10
 * Number of states: 41 (Droop.currentLoop.integratord.y,Droop.currentLoop.integratorq.y,Droop.voltageLoop.integratord.y,Droop.voltageLoop.integratorq.y,Droop.droopControl.firstOrder.y,Droop.droopControl.integrator.y,Droop.droopControl.firstOrder1.y,Droop.droopControl.firstOrder2.y,Droop.droopControl.firstOrder3.y,Conv250.udFilterPu,Conv250.uqFilterPu,Conv250.idConvPu,Conv250.iqConvPu,Conv250.idPccPu,Conv250.iqPccPu,Conv250.UdcSourcePu,dVOC.currentLoop.integratord.y,dVOC.currentLoop.integratorq.y,dVOC.voltageLoop.integratord.y,dVOC.voltageLoop.integratorq.y,dVOC.dispatchableVirtualOscillatorControl.integrator.y,dVOC.dispatchableVirtualOscillatorControl.UFilterRefRawPu,Conv500.udFilterPu,Conv500.uqFilterPu,Conv500.idConvPu,Conv500.iqConvPu,Conv500.idPccPu,Conv500.iqPccPu,Conv500.UdcSourcePu,Matching.currentLoop.integratord.y,Matching.currentLoop.integratorq.y,Matching.voltageLoop.integratord.y,Matching.voltageLoop.integratorq.y,Matching.matchingControl.integrator.y,Conv1000.udFilterPu,Conv1000.uqFilterPu,Conv1000.idConvPu,Conv1000.iqConvPu,Conv1000.idPccPu,Conv1000.iqPccPu,Conv1000.UdcSourcePu)
 * Number of discrete variables: 53 ($whenCondition29,$whenCondition30,$whenCondition28,$whenCondition26,$whenCondition27,$whenCondition25,$whenCondition23,$whenCondition24,$whenCondition22,$whenCondition20,$whenCondition21,$whenCondition18,$whenCondition19,$whenCondition16,$whenCondition17,$whenCondition15,$whenCondition13,$whenCondition14,$whenCondition12,$whenCondition10,$whenCondition11,$whenCondition9,$whenCondition7,$whenCondition8,$whenCondition6,$whenCondition4,$whenCondition5,$whenCondition3,$whenCondition1,$whenCondition2,Conv250.running.value,Conv250.state,Conv250.converter.u,Conv500.running.value,Conv500.state,Conv500.converter.u,Conv1000.running.value,Conv1000.state,Conv1000.converter.u,Line12.running.value,Line12.state,Line13.running.value,Line13.state,Line23.running.value,Line23.state,Line23Bis1.running.value,Line23Bis1.state,Line23Bis2.running.value,Line23Bis2.state,Load.running.value,Load.state,Fault.nodeFault.value,Disconnection.y)
 * Number of discrete states: 9 (Conv250.running.value,Conv500.running.value,Conv1000.running.value,Line13.running.value,Line23.running.value,Line23Bis1.running.value,Line23Bis2.running.value,Load.running.value,Line12.running.value)
 * Number of clocked states: 0 ()
 * Top-level inputs: 0
Notification: Strong component statistics for simulation (371):
 * Single equations (assignments): 322
 * Array equations: 0
 * Algorithm blocks: 0
 * Record equations: 0
 * When equations: 19
 * If-equations: 0
 * Equation systems (not torn): 24
 * Torn equation systems: 6
 * Mixed (continuous/discrete) equation systems: 0
Notification: Equation system details (not torn):
 * Constant Jacobian (size): 0 systems
 * Linear Jacobian (size,density): 3 systems
   {(2,100.0%), (2,100.0%), (2,100.0%)}
 * Non-linear Jacobian (size): 21 systems
   {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1}
 * Without analytic Jacobian (size): 0 systems
Notification: Torn system details for strict tearing set:
 * Linear torn systems (#iteration vars, #inner vars, density): 4 systems
   {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)}
 * Non-linear torn systems (#iteration vars, #inner vars): 2 systems
   {(1,1), (24,10)}
Notification: Performance of Backend phase and start with SimCode phase: time 0.000851/1.027, allocations: 299.7 kB / 0.9231 GB, free: 9.465 MB / 0.6075 GB
Notification: Performance of simCode: created initialization part: time 0.01258/1.039, allocations: 6.618 MB / 0.9295 GB, free: 2.734 MB / 0.6075 GB
Notification: Performance of simCode: created event and clocks part: time 8.316e-06/1.039, allocations: 4 kB / 0.9295 GB, free: 2.73 MB / 0.6075 GB
Notification: Performance of simCode: created simulation system equations: time 0.01084/1.05, allocations: 3.443 MB / 0.9329 GB, free: 15.21 MB / 0.6231 GB
Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.004933/1.055, allocations: 0.526 MB / 0.9334 GB, free: 14.7 MB / 0.6231 GB
Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.02081/1.076, allocations: 7.952 MB / 0.9412 GB, free: 6.699 MB / 0.6231 GB
Notification: Performance of simCode: some other stuff during SimCode phase: time 0.003311/1.079, allocations: 2.214 MB / 0.9433 GB, free: 4.453 MB / 0.6231 GB
Notification: Performance of simCode: alias equations: time 0.002948/1.082, allocations: 395.6 kB / 0.9437 GB, free: 4.062 MB / 0.6231 GB
Notification: Performance of simCode: all other stuff during SimCode phase: time 0.001807/1.084, allocations: 255.4 kB / 0.944 GB, free: 3.812 MB / 0.6231 GB
Notification: Performance of SimCode: time 1.572e-06/1.084, allocations: 3.938 kB / 0.944 GB, free: 3.809 MB / 0.6231 GB
Notification: Performance of Templates: time 0.1213/1.205, allocations: 63.83 MB / 1.006 GB, free: 4.203 MB / 0.6856 GB
"
[Timeout remaining time 659]
make -j1 -f Dynawo_dev_Dynawo.Examples.GridForming.GridForming.makefile [Timeout 660]
(rm -f Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe ; mkfifo Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe ; head -c 1048576 < Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe >> ../files/Dynawo_dev_Dynawo.Examples.GridForming.GridForming.sim & ./Dynawo_dev_Dynawo.Examples.GridForming.GridForming  -initialStepSize=0.001 -lv=LOG_STATS -s=ida -maxIntegrationOrder=2 -maxStepSize=10 -abortSlowSimulation -alarm=480  -emit_protected -lv LOG_STATS > Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe 2>&1) [Timeout 480]
diffSimulationResults("Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat","/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ReferenceFiles/Dynawo/dynawo/sources/Models/Modelica/Dynawo/Examples/references/Dynawo.Examples.GridForming.GridForming_res.csv","/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/Dynawo_dev_Dynawo.Examples.GridForming.GridForming.diff",relTol=0.003,relTolDiffMinMax=0.003,rangeDelta=0.001) [Timeout 660]
""
[Timeout remaining time 660]
Reference file matches
[Calling sys.exit(0), Time elapsed: 10.076192437671125]