Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Chemical_master_Chemical.Examples.SimpleReactionsWithJunction.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001926/0.001926, allocations: 109.1 kB / 18.94 MB, free: 2.812 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.00236/0.00236, allocations: 215.5 kB / 22.25 MB, free: 5.184 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.483/1.483, allocations: 230.6 MB / 256 MB, free: 8.004 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo): time 0.1437/0.1437, allocations: 23.89 MB / 336.3 MB, free: 11.18 MB / 270.1 MB " [Timeout remaining time 180] Using package Chemical with version 2.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Chemical.Examples.SimpleReactionsWithJunction,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Chemical_master_Chemical.Examples.SimpleReactionsWithJunction") translateModel(Chemical.Examples.SimpleReactionsWithJunction,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Chemical_master_Chemical.Examples.SimpleReactionsWithJunction") [Timeout 660] "Notification: Chemical requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002151/0.002151, allocations: 63.91 kB / 471.7 MB, free: 7.176 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3273/0.3294, allocations: 59.87 MB / 0.5191 GB, free: 9.789 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1098:7-1098:40:writable] Warning: An inner declaration for outer component dropOfCommons could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1098:7-1098:40:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"dropOfCommons\" component but an inner \"dropOfCommons\" component is not defined. Use Chemical.DropOfCommons in your model to specify system properties. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1697:7-1697:66:writable] Warning: An inner declaration for outer component system could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1697:7-1697:66:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"system\" component but an inner \"system\" component is not defined. For simulation drag Modelica.Fluid.System into your model to specify system properties. Notification: Performance of NFInst.instantiate(Chemical.Examples.SimpleReactionsWithJunction): time 0.05718/0.3866, allocations: 43.93 MB / 0.562 GB, free: 12.91 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.0256/0.4122, allocations: 13.04 MB / 0.5748 GB, free: 1.07 MB / 414.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.006385/0.4186, allocations: 99.5 kB / 0.5748 GB, free: 0.9727 MB / 414.1 MB Notification: Performance of NFTyping.typeComponents: time 0.007763/0.4264, allocations: 2.52 MB / 0.5773 GB, free: 14.44 MB / 430.1 MB Notification: Performance of NFTyping.typeBindings: time 0.009386/0.4358, allocations: 2.149 MB / 0.5794 GB, free: 12.27 MB / 430.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.01059/0.4463, allocations: 4.522 MB / 0.5838 GB, free: 7.734 MB / 430.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1311:3-1311:46:writable] Error: Parameter r.nextProducts[1].data.MM has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0008339/0.4472, allocations: 298.4 kB / 0.5841 GB, free: 7.441 MB / 430.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.971638046205044] Failed to read output from testmodel.py, exit status != 0: 0.4551774929277599 0.47073876800000003 -1.0 Calling exit ...