Environment - simulationEnvironment:
startTime=1.87488e+07
stopTime=1.93536e+07
tolerance=1e-06
numberOfIntervals=2513
stepSize=240.669
Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer  -abortSlowSimulation -alarm=800  -emit_protected -lv LOG_STATS
EnergyPlus Starting
EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2025.04.27 11:14
Adjusting Air System Sizing
Adjusting Standard 62.1 Ventilation Sizing
Initializing Simulation
Reporting Surfaces
Beginning Primary Simulation
Initializing New Environment Parameters
Warming up {1}
Warming up {2}
Warming up {3}
Warming up {4}
Warming up {5}
Warming up {6}
Warming up {7}
Warming up {8}
Warming up {9}
Warming up {10}
Warming up {11}
Starting Simulation at 08/06/2006 for SPAWN-RUNPERIOD
LOG_STDOUT        | info    | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1.
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable]
|                 | |       | The following assertion has been violated at time 18748800.000000
|                 | |       | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |   0.00738926s          reading init.xml
|                 | |       | | |  0.000563878s          reading info.xml
|                 | |       | | |  0.000230832s [  0.0%] pre-initialization
|                 | |       | | |      6.73905s [ 95.8%] initialization
|                 | |       | | |    4.618e-06s [  0.0%] steps
|                 | |       | | |   0.00928033s [  0.1%] solver (excl. callbacks)
|                 | |       | | |   0.00133189s [  0.0%] creating output-file
|                 | |       | | |     0.241049s [  3.4%] event-handling
|                 | |       | | |   0.00509676s [  0.1%] overhead
|                 | |       | | |    0.0371669s [  0.5%] simulation
|                 | |       | | |      7.03321s [100.0%] total
|                 | |       | | events
|                 | |       | | |   504 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |  9960 steps taken
|                 | |       | | | 13074 calls of functionODE
|                 | |       | | |  6037 evaluations of jacobian
|                 | |       | | |   260 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.015853s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.
Writing tabular output file results using HTML format.
EnergyPlus Run Time=00hr 00min  0.58sec
EnergyPlus Completed Successfully.