Environment - simulationEnvironment:
startTime=7.344e+06
stopTime=7.776e+06
tolerance=1e-07
numberOfIntervals=2500
stepSize=172.8
Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Spring  -abortSlowSimulation -alarm=800  -emit_protected -lv LOG_STATS
EnergyPlus Starting
EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2025.04.27 11:13
Adjusting Air System Sizing
Adjusting Standard 62.1 Ventilation Sizing
Initializing Simulation
Reporting Surfaces
Beginning Primary Simulation
Initializing New Environment Parameters
Warming up {1}
Warming up {2}
Warming up {3}
Warming up {4}
Warming up {5}
Warming up {6}
Warming up {7}
Warming up {8}
Warming up {9}
Warming up {10}
Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable]
|                 | |       | The following assertion has been violated at time 7344172.800000
|                 | |       | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -3.20869e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable]
|                 | |       | The following assertion has been violated at time 7344172.800000
|                 | |       | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -1.57004e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable]
|                 | |       | The following assertion has been violated at time 7344172.800000
|                 | |       | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -2.43241e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable]
|                 | |       | The following assertion has been violated at time 7344172.800000
|                 | |       | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -1.57004e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable]
|                 | |       | The following assertion has been violated at time 7344172.800000
|                 | |       | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -2.43241e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable]
|                 | |       | The following assertion has been violated at time 7344345.600000
|                 | |       | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -8.50053e-17"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 7344345.600000
|                 | |       | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -3.44824e-21"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 7368530.265974
|                 | |       | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -1.1792e-94"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable]
|                 | |       | The following assertion has been violated at time 7370265.600000
|                 | |       | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: 1"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable]
|                 | |       | The following assertion has been violated at time 7412601.600000
|                 | |       | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -6.13919e-25"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 7412601.600000
|                 | |       | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -4.2487e-27"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 7412601.600000
|                 | |       | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -6.46808e-164"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable]
|                 | |       | The following assertion has been violated at time 7412774.400000
|                 | |       | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -3.80907e-13"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 7413000.000074
|                 | |       | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.81007e-52"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable]
|                 | |       | The following assertion has been violated at time 7499001.600000
|                 | |       | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -9.55758e-27"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable]
|                 | |       | The following assertion has been violated at time 7499001.600000
|                 | |       | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -7.59054e-15"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 7499001.600000
|                 | |       | ((hvac.pumHeaCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -1.07485e-27"
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |     0.158703s          reading init.xml
|                 | |       | | |    0.0113404s          reading info.xml
|                 | |       | | |   0.00355816s [  0.0%] pre-initialization
|                 | |       | | |      6.88879s [  4.3%] initialization
|                 | |       | | |    0.0201252s [  0.0%] steps
|                 | |       | | |      3.73515s [  2.4%] solver (excl. callbacks)
|                 | |       | | |    0.0430141s [  0.0%] creating output-file
|                 | |       | | |      6.52139s [  4.1%] event-handling
|                 | |       | | |    0.0606151s [  0.0%] overhead
|                 | |       | | |      141.302s [ 89.1%] simulation
|                 | |       | | |      158.575s [100.0%] total
|                 | |       | | events
|                 | |       | | |   851 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | | 90593 steps taken
|                 | |       | | | 168247 calls of functionODE
|                 | |       | | | 91319 evaluations of jacobian
|                 | |       | | |  2017 error test failures
|                 | |       | | | 25899 convergence test failures
|                 | |       | | | 133.417s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.
Writing final SQL reports
EnergyPlus Run Time=00hr 02min 32.09sec
EnergyPlus Completed Successfully.