Environment - simulationEnvironment:
startTime=0
stopTime=86400
tolerance=1e-06
numberOfIntervals=2500
stepSize=34.56
Regular simulation: ./Buildings_12_Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.SingleCircuitMultipleCircuitFiniteDifference  -abortSlowSimulation -alarm=400  -emit_protected -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |     0.109339s          reading init.xml
|                 | |       | | |   0.00739973s          reading info.xml
|                 | |       | | |   0.00224065s [  2.0%] pre-initialization
|                 | |       | | |  0.000930836s [  0.8%] initialization
|                 | |       | | |   7.4831e-05s [  0.1%] steps
|                 | |       | | |    0.0138355s [ 12.2%] solver (excl. callbacks)
|                 | |       | | |   0.00586439s [  5.2%] creating output-file
|                 | |       | | |  0.000667006s [  0.6%] event-handling
|                 | |       | | |    0.0108579s [  9.6%] overhead
|                 | |       | | |    0.0790478s [ 69.6%] simulation
|                 | |       | | |     0.113519s [100.0%] total
|                 | |       | | events
|                 | |       | | |     4 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   918 steps taken
|                 | |       | | |  1131 calls of functionODE
|                 | |       | | |   121 evaluations of jacobian
|                 | |       | | |     5 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.0101369s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.