Environment - simulationEnvironment: startTime=0 stopTime=360000 tolerance=1e-06 numberOfIntervals=12529 stepSize=28.7333 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerBorefield -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.hex.pum1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.hex.pum1.per.haveWMot_nominal or not (ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.hex.pum1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.hex.pum2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.hex.pum2.per.haveWMot_nominal or not (ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.hex.pum2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.chi.pumCon: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.chi.pumCon.per.haveWMot_nominal or not (ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.chi.pumCon: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.chi.pumEva: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.chi.pumEva.per.haveWMot_nominal or not (ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.chi.pumEva: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.borFie.pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.borFie.pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.borFie.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.borFie.pum.per.haveWMot_nominal or not (ets.borFie.pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.borFie.pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.borFie.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumChiWat.per.haveWMot_nominal or not (pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.pumHeaWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaWat.per.haveWMot_nominal or not (pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.pumHeaWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 3840.000000 | | | | ((ets.hex.m2_flow >= 0.0 and ets.hex.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ets.hex.m2_flow <= 1e5, has value: -7.37228e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium: Temperature T = 403.407 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium: Temperature T = 403.795 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium: Temperature T = 404.147 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium: Temperature T = 404.466 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.val.vol.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.val.vol.dynBal.medium: Temperature T = 403.176 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.val.vol.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.val.vol.dynBal.medium: Temperature T = 403.176 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium: Temperature T = 404.466 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium: Temperature T = 404.147 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium: Temperature T = 403.795 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium: Temperature T = 403.407 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.val.vol.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.val.vol.dynBal.medium: Temperature T = 403.176 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium: Temperature T = 404.466 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium: Temperature T = 404.147 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium: Temperature T = 403.795 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14640.000000 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium: Temperature T = 403.407 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[7].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[7].vol2.dynBal.medium: Temperature T = 403.455 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[6].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[6].vol2.dynBal.medium: Temperature T = 403.929 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[5].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[5].vol2.dynBal.medium: Temperature T = 404.38 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[4].vol2.dynBal.medium: Temperature T = 404.801 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[3].vol2.dynBal.medium: Temperature T = 405.19 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[2].vol2.dynBal.medium: Temperature T = 405.543 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[2].vol1.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[2].vol1.dynBal.medium: Temperature T = 403.458 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[1].vol2.dynBal.medium: Temperature T = 405.865 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.borFie.borHol.intHex[1].vol1.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.borFie.borHol.intHex[1].vol1.dynBal.medium: Temperature T = 404.113 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.2-maint.10.0.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 14654.002714 | | | | ((noEvent(ets.borFie.val.vol.dynBal.medium.T <= 403.15))) --> "In ChillerBorefield.ets.borFie.val.vol.dynBal.medium: Temperature T = 404.633 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now!