Environment - simulationEnvironment:
startTime=0
stopTime=1000
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.4
Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.ScrollWaterToWater_ScalingFactor  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0129385s          reading init.xml
|                 | |       | | |   0.00111697s          reading info.xml
|                 | |       | | |  0.000110577s [  0.1%] pre-initialization
|                 | |       | | |  0.000402184s [  0.4%] initialization
|                 | |       | | |  0.000176531s [  0.2%] steps
|                 | |       | | |    0.0012401s [  1.1%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   0.00101254s [  0.9%] event-handling
|                 | |       | | |   0.00663581s [  6.0%] overhead
|                 | |       | | |     0.100914s [ 91.3%] simulation
|                 | |       | | |     0.110492s [100.0%] total
|                 | |       | | events
|                 | |       | | |     4 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   455 steps taken
|                 | |       | | |   576 calls of functionODE
|                 | |       | | |    82 evaluations of jacobian
|                 | |       | | |    16 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.00355432s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.