Environment - simulationEnvironment:
startTime=0
stopTime=86400
tolerance=1e-08
numberOfIntervals=2500
stepSize=34.56
Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.Modular_OneRoomRadiator  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in Modular_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve.
|                 | |       | This leads to an approximate power consumption.
|                 | |       | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:144:3-149:28:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((heaPum.refCyc.refCycHeaPumCoo.mCon_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mCon_flow_max)) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal condenser mass flow rate (0.956023 kg/s) is bigger than the 
|                 | |       |     maximal value (0.841737 kg/s) for the table data 
|                 | |       |     when assuming a temperature spread between 3 and 10 K, as in EN 14511."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:156:3-161:28:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((heaPum.refCyc.refCycHeaPumCoo.mEva_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mEva_flow_max)) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal evaporator mass flow rate (5.58642 kg/s) is bigger than the 
|                 | |       |     maximal value (3.03188 kg/s) for the table data 
|                 | |       |     when assuming a temperature spread between 3 and 10 K, as in EN 14511."
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0545937s          reading init.xml
|                 | |       | | |    0.0061447s          reading info.xml
|                 | |       | | |  0.000237295s [  0.2%] pre-initialization
|                 | |       | | |    0.0414617s [ 26.9%] initialization
|                 | |       | | |   2.7051e-05s [  0.0%] steps
|                 | |       | | |   0.00713052s [  4.6%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |     0.026897s [ 17.4%] event-handling
|                 | |       | | |    0.0102615s [  6.6%] overhead
|                 | |       | | |    0.0683205s [ 44.3%] simulation
|                 | |       | | |     0.154336s [100.0%] total
|                 | |       | | events
|                 | |       | | |    18 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |  4182 steps taken
|                 | |       | | |  5026 calls of functionODE
|                 | |       | | |   466 evaluations of jacobian
|                 | |       | | |    79 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.0186103s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.