Environment - simulationEnvironment:
startTime=0
stopTime=3.1536e+07
tolerance=1e-06
numberOfIntervals=2500
stepSize=12614.4
Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.Geothermal.Aquifer.Validation.SimulationTest  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable]
|                 | |       | The following assertion has been violated at time 12614.400000
|                 | |       | ((aquWel.pumCol.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumCol.etaHyd, has value: -0.0239763"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable]
|                 | |       | The following assertion has been violated at time 12614.400000
|                 | |       | ((aquWel.pumCol.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumCol.heaDis.etaHyd, has value: -6.4348"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 37843.200000
|                 | |       | ((aquWel.pumCol.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumCol.eff.yMot, has value: -1.04876e-61"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable]
|                 | |       | The following assertion has been violated at time 10369036.800000
|                 | |       | ((aquWel.pumHot.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumHot.etaHyd, has value: -7.28643e-51"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable]
|                 | |       | The following assertion has been violated at time 10369036.800000
|                 | |       | ((aquWel.pumHot.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumHot.heaDis.etaHyd, has value: -1.95554e-48"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 10381651.200000
|                 | |       | ((aquWel.pumHot.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumHot.eff.yMot, has value: -2.02455e-53"
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |     0.678913s          reading init.xml
|                 | |       | | |     0.052398s          reading info.xml
|                 | |       | | |  0.000626064s [  0.0%] pre-initialization
|                 | |       | | |   0.00856973s [  0.4%] initialization
|                 | |       | | |  0.000414006s [  0.0%] steps
|                 | |       | | |      0.27485s [ 14.0%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   0.00425578s [  0.2%] event-handling
|                 | |       | | |     0.110828s [  5.6%] overhead
|                 | |       | | |      1.56345s [ 79.6%] simulation
|                 | |       | | |      1.96299s [100.0%] total
|                 | |       | | events
|                 | |       | | |     3 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   917 steps taken
|                 | |       | | |  1193 calls of functionODE
|                 | |       | | |   127 evaluations of jacobian
|                 | |       | | |    16 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.193672s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.