Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3.conf.json
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001507/0.001507, allocations: 113.9 kB / 18.94 MB, free: 2.93 MB / 14.72 MB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001681/0.001681, allocations: 188.6 kB / 22.23 MB, free: 5.102 MB / 14.72 MB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.309/1.309, allocations: 225.6 MB / 251 MB, free: 13.02 MB / 206.1 MB
"
[Timeout remaining time 179]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.002406/0.002406, allocations: 280.5 kB / 306.5 MB, free: 8.34 MB / 238.1 MB
"
[Timeout remaining time 180]
loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) [Timeout 180]
"Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 1.145/1.145, allocations: 180.9 MB / 0.53 GB, free: 14.45 MB / 382.1 MB
"
[Timeout remaining time 179]
Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo)
Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo)
Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo)
Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo)
Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo)
Running command: translateModel(BuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3")
translateModel(BuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3") [Timeout 660]
Thread is still alive.
Aborted the command.
[Calling os._exit(0), Time elapsed: 665.5913805346936]
Failed to read output from testmodel.py, exit status != 0:
Calling exit ...
<OMPython.OMCSessionZMQ object at 0x7faca46457b0>