Environment - simulationEnvironment:
startTime=0
stopTime=600
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.24
Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Sources.Examples.TraceSubstancesFlowSource  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not C.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not C1.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C1 can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C1."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not C2.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C2 can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C2."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not C3.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C3 can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C3."
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0163934s          reading init.xml
|                 | |       | | |   0.00111215s          reading info.xml
|                 | |       | | |  0.000134633s [  0.5%] pre-initialization
|                 | |       | | |   0.00039446s [  1.4%] initialization
|                 | |       | | |    7.053e-06s [  0.0%] steps
|                 | |       | | |  0.000903095s [  3.2%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |  0.000158096s [  0.6%] event-handling
|                 | |       | | |   0.00289789s [ 10.3%] overhead
|                 | |       | | |    0.0236608s [ 84.0%] simulation
|                 | |       | | |     0.028156s [100.0%] total
|                 | |       | | events
|                 | |       | | |     1 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   124 steps taken
|                 | |       | | |   182 calls of functionODE
|                 | |       | | |    42 evaluations of jacobian
|                 | |       | | |     1 error test failures
|                 | |       | | |     2 convergence test failures
|                 | |       | | | 0.00124271s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.