Environment - simulationEnvironment:
startTime=0
stopTime=200
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.08
Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.PowerSimplified  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((pump_dp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the
|                 | |       |              default pressure curve.
|                 | |       |              This leads to approximate calculations of the electrical power
|                 | |       |              consumption. Add the correct pressure curve in the record per
|                 | |       |              to obtain an accurate computation.
|                 | |       |              Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the
|                 | |       |              default pressure curve.
|                 | |       |              This leads to approximate calculations of the electrical power
|                 | |       |              consumption. Add the correct pressure curve in the record per
|                 | |       |              to obtain an accurate computation.
|                 | |       |              Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning."
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0226375s          reading init.xml
|                 | |       | | |   0.00199799s          reading info.xml
|                 | |       | | |  0.000119023s [  0.6%] pre-initialization
|                 | |       | | |  0.000723126s [  3.8%] initialization
|                 | |       | | |    3.516e-06s [  0.0%] steps
|                 | |       | | |  0.000430473s [  2.3%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   0.00020354s [  1.1%] event-handling
|                 | |       | | |   0.00533001s [ 28.2%] overhead
|                 | |       | | |    0.0120627s [ 63.9%] simulation
|                 | |       | | |    0.0188724s [100.0%] total
|                 | |       | | events
|                 | |       | | |     2 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |    70 steps taken
|                 | |       | | |    87 calls of functionODE
|                 | |       | | |    54 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.000123264s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.