Environment - simulationEnvironment:
startTime=0
stopTime=1
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.0004
Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Examples.MoverParameter  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the
|                 | |       |              default pressure curve.
|                 | |       |              This leads to approximate calculations of the electrical power
|                 | |       |              consumption. Add the correct pressure curve in the record per
|                 | |       |              to obtain an accurate computation.
|                 | |       |              Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not (pump_m_flow.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_m_flow.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in MoverParameter.pump_m_flow: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber.
|                 | |       |              This requires that per.pressure be provided.
|                 | |       |              Because it is not,
|                 | |       |              the model will override this setting and use .NotProvided instead."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((pump_m_flow.per.haveWMot_nominal or not (pump_m_flow.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump_m_flow.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in MoverParameter.pump_m_flow: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio
|                 | |       |              or .GenericCurve. This requires that per.WMot_nominal be provided
|                 | |       |              or at least per.pressure be provided so that per.WMot_nominal can
|                 | |       |              be estimated. Because neither is provided,
|                 | |       |              the model will override this setting and use .NotProvided instead."
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0287662s          reading init.xml
|                 | |       | | |   0.00249865s          reading info.xml
|                 | |       | | |   9.5239e-05s [  0.4%] pre-initialization
|                 | |       | | |  0.000858249s [  3.6%] initialization
|                 | |       | | |      5.5e-06s [  0.0%] steps
|                 | |       | | |    4.441e-06s [  0.0%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | | -1.32349e-23s [ -0.0%] event-handling
|                 | |       | | |   0.00569486s [ 23.9%] overhead
|                 | |       | | |    0.0172001s [ 72.0%] simulation
|                 | |       | | |    0.0238759s [100.0%] total
|                 | |       | | events
|                 | |       | | |     0 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: euler
|                 | |       | | |  2500 steps taken
|                 | |       | | |  2500 calls of functionODE
|                 | |       | | |     0 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.