Environment - simulationEnvironment:
startTime=0
stopTime=1
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.0004
Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((false)) --> "*** Warning: You are using a flow or pressure controlled mover with the
|                 | |       |              default pressure curve.
|                 | |       |              This leads to approximate calculations of the electrical power
|                 | |       |              consumption. Add the correct pressure curve in the record per
|                 | |       |              to obtain an accurate computation.
|                 | |       |              Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((false)) --> "*** Warning in HeaterFan.floMac.com: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber.
|                 | |       |              This requires that per.pressure be provided.
|                 | |       |              Because it is not,
|                 | |       |              the model will override this setting and use .NotProvided instead."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((false)) --> "*** Warning in HeaterFan.floMac.com: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio
|                 | |       |              or .GenericCurve. This requires that per.WMot_nominal be provided
|                 | |       |              or at least per.pressure be provided so that per.WMot_nominal can
|                 | |       |              be estimated. Because neither is provided,
|                 | |       |              the model will override this setting and use .NotProvided instead."
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0107713s          reading init.xml
|                 | |       | | |   0.00092259s          reading info.xml
|                 | |       | | |   7.6023e-05s [  1.3%] pre-initialization
|                 | |       | | |  0.000346871s [  6.0%] initialization
|                 | |       | | |     9.02e-07s [  0.0%] steps
|                 | |       | | |   2.8116e-05s [  0.5%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   1.2254e-05s [  0.2%] event-handling
|                 | |       | | |   0.00221397s [ 38.4%] overhead
|                 | |       | | |   0.00309206s [ 53.6%] simulation
|                 | |       | | |    0.0057702s [100.0%] total
|                 | |       | | events
|                 | |       | | |     0 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: euler
|                 | |       | | |  2500 steps taken
|                 | |       | | |  2500 calls of functionODE
|                 | |       | | |     0 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.