Environment - simulationEnvironment:
startTime=0
stopTime=20
tolerance=1e-06
numberOfIntervals=2500
stepSize=0.008
Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Examples.Performance.Example3  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not (pump.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Example3.pump: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber.
|                 | |       |              This requires that per.pressure be provided.
|                 | |       |              Because it is not,
|                 | |       |              the model will override this setting and use .NotProvided instead."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Example3.pump: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio
|                 | |       |              or .GenericCurve. This requires that per.WMot_nominal be provided
|                 | |       |              or at least per.pressure be provided so that per.WMot_nominal can
|                 | |       |              be estimated. Because neither is provided,
|                 | |       |              the model will override this setting and use .NotProvided instead."
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0100376s          reading init.xml
|                 | |       | | |  0.000904796s          reading info.xml
|                 | |       | | |   9.3395e-05s [  0.8%] pre-initialization
|                 | |       | | |  0.000324639s [  2.8%] initialization
|                 | |       | | |   1.1201e-05s [  0.1%] steps
|                 | |       | | |  0.000641285s [  5.6%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |    0.0005629s [  4.9%] event-handling
|                 | |       | | |   0.00296739s [ 26.0%] overhead
|                 | |       | | |   0.00682949s [ 59.7%] simulation
|                 | |       | | |    0.0114303s [100.0%] total
|                 | |       | | events
|                 | |       | | |    40 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   677 steps taken
|                 | |       | | |   677 calls of functionODE
|                 | |       | | |   636 evaluations of jacobian
|                 | |       | | |     0 error test failures
|                 | |       | | |     0 convergence test failures
|                 | |       | | | 0.000559416s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.