Environment - simulationEnvironment:
startTime=0
stopTime=86400
tolerance=1e-06
numberOfIntervals=2500
stepSize=34.56
Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Airflow.Multizone.Examples.CO2TransportStep  -abortSlowSimulation -alarm=480 -lv LOG_STATS
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not CO2SenTop.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenTop can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenTop."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not CO2SenWes.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenWes can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenWes."
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((not CO2SenEas.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenEas can lead to numerical problems if connected to a scalar fluid port.
|                 | |       |   Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`.
|                 | |       |   See IBPSA.Fluid.Sensors.UsersGuide for more information.
|                 | |       |   To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenEas."
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_STATS         | info    | ### STATISTICS ###
|                 | |       | | timer
|                 | |       | | |    0.0134549s          reading init.xml
|                 | |       | | |  0.000893496s          reading info.xml
|                 | |       | | |  0.000133571s [  0.9%] pre-initialization
|                 | |       | | |  0.000221225s [  1.5%] initialization
|                 | |       | | |    3.646e-06s [  0.0%] steps
|                 | |       | | |  0.000874381s [  6.1%] solver (excl. callbacks)
|                 | |       | | |            0s [  0.0%] creating output-file
|                 | |       | | |   0.00193226s [ 13.4%] event-handling
|                 | |       | | |   0.00200515s [ 13.9%] overhead
|                 | |       | | |     0.009219s [ 64.1%] simulation
|                 | |       | | |    0.0143892s [100.0%] total
|                 | |       | | events
|                 | |       | | |     6 state events
|                 | |       | | |     0 time events
|                 | |       | | solver: dassl
|                 | |       | | |   165 steps taken
|                 | |       | | |   262 calls of functionODE
|                 | |       | | |    82 evaluations of jacobian
|                 | |       | | |     5 error test failures
|                 | |       | | |     2 convergence test failures
|                 | |       | | | 0.000872838s time of jacobian evaluation
LOG_SUCCESS       | info    | The simulation finished successfully.