Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=480 stepSize=15 Regular simulation: ./AixLib_AixLib.Systems.ModularAHU.Examples.EONERC_AHU2 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in EONERC_AHU2.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in EONERC_AHU2.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((genericAHU.preheater.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0, has value: -2.41831e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 1185.000000 | | | | ((genericAHU.cooler.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0, has value: -1.47921e-18" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.250371s reading init.xml | | | | | | 0.0203538s reading info.xml | | | | | | 0.000409098s [ 0.0%] pre-initialization | | | | | | 0.00236406s [ 0.0%] initialization | | | | | | 0.0482827s [ 0.2%] steps | | | | | | 5.73843s [ 18.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.31571s [ 4.2%] event-handling | | | | | | 0.0190669s [ 0.1%] overhead | | | | | | 24.3682s [ 77.4%] simulation | | | | | | 31.4924s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 17865 steps taken | | | | | | 43180 calls of functionODE | | | | | | 18693 evaluations of jacobian | | | | | | 882 error test failures | | | | | | 5402 convergence test failures | | | | | | 20.9006s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.