Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.822/0.822, allocations: 153.9 MB / 172.7 MB, free: 4.957 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005339/0.0005339, allocations: 7.984 kB / 249.9 MB, free: 4.445 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1642/0.1647, allocations: 33.36 MB / 283.2 MB, free: 1.816 MB / 222.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan): time 1.833/1.997, allocations: 312 MB / 0.5813 GB, free: 16 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.1727/2.17, allocations: 155.8 MB / 0.7335 GB, free: 4.801 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001126/2.171, allocations: 12 kB / 0.7335 GB, free: 4.789 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:48:3-50:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:51:3-52:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:53:3-55:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:56:3-57:83:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.000757/2.172, allocations: 223.9 kB / 0.7337 GB, free: 4.574 MB / 0.5919 GB Notification: Performance of NFTyping.typeBindings: time 0.001233/2.173, allocations: 499.4 kB / 0.7342 GB, free: 4.082 MB / 0.5919 GB Notification: Performance of NFTyping.typeClassSections: time 0.003819/2.177, allocations: 1.515 MB / 0.7357 GB, free: 2.562 MB / 0.5919 GB Notification: Performance of NFFlatten.flatten: time 0.003015/2.18, allocations: 2.382 MB / 0.738 GB, free: 180 kB / 0.5919 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001386/2.181, allocations: 1.039 MB / 0.739 GB, free: 15.1 MB / 0.6075 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001093/2.183, allocations: 0.9075 MB / 0.7399 GB, free: 14.19 MB / 0.6075 GB Notification: Performance of NFSimplifyModel.simplify: time 0.001266/2.184, allocations: 1.074 MB / 0.7409 GB, free: 13.11 MB / 0.6075 GB Notification: Performance of NFPackage.collectConstants: time 0.0003112/2.184, allocations: 244 kB / 0.7412 GB, free: 12.87 MB / 0.6075 GB Notification: Performance of NFFlatten.collectFunctions: time 0.002653/2.187, allocations: 1.257 MB / 0.7424 GB, free: 11.61 MB / 0.6075 GB Notification: Performance of NFScalarize.scalarize: time 0.0004359/2.187, allocations: 0.5063 MB / 0.7429 GB, free: 11.11 MB / 0.6075 GB Notification: Performance of NFVerifyModel.verify: time 0.001013/2.188, allocations: 1.038 MB / 0.7439 GB, free: 10.06 MB / 0.6075 GB Notification: Performance of NFConvertDAE.convert: time 0.003935/2.192, allocations: 2.909 MB / 0.7468 GB, free: 7.145 MB / 0.6075 GB Notification: Performance of FrontEnd - DAE generated: time 4.819e-06/2.192, allocations: 0.6562 kB / 0.7468 GB, free: 7.145 MB / 0.6075 GB Notification: Performance of FrontEnd: time 1.773e-06/2.192, allocations: 3.938 kB / 0.7468 GB, free: 7.141 MB / 0.6075 GB Notification: Performance of Transformations before backend: time 3.433e-05/2.192, allocations: 0 / 0.7468 GB, free: 7.141 MB / 0.6075 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 509 * Number of variables: 509 Notification: Performance of Generate backend data structure: time 0.00456/2.197, allocations: 2.22 MB / 0.7489 GB, free: 4.883 MB / 0.6075 GB Notification: Performance of prepare preOptimizeDAE: time 4.534e-05/2.197, allocations: 12.03 kB / 0.7489 GB, free: 4.871 MB / 0.6075 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0003198/2.197, allocations: 283 kB / 0.7492 GB, free: 4.586 MB / 0.6075 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003764/2.198, allocations: 231.6 kB / 0.7494 GB, free: 4.359 MB / 0.6075 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.001081/2.199, allocations: 0.6743 MB / 0.7501 GB, free: 3.656 MB / 0.6075 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001927/2.199, allocations: 209.1 kB / 0.7503 GB, free: 3.441 MB / 0.6075 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0004315/2.199, allocations: 216 kB / 0.7505 GB, free: 3.23 MB / 0.6075 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.003709/2.203, allocations: 2.353 MB / 0.7528 GB, free: 0.7227 MB / 0.6075 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.052e-05/2.203, allocations: 7.938 kB / 0.7528 GB, free: 0.7148 MB / 0.6075 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001608/2.203, allocations: 84 kB / 0.7529 GB, free: 0.6328 MB / 0.6075 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 4.513e-05/2.203, allocations: 55.94 kB / 0.7529 GB, free: 0.5781 MB / 0.6075 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.003753/2.207, allocations: 2.08 MB / 0.755 GB, free: 14.49 MB / 0.6231 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01452/2.221, allocations: 14.43 MB / 0.7691 GB, free: 14.53 MB / 0.6387 GB Notification: Performance of preOpt comSubExp (simulation): time 0.002/2.223, allocations: 1.028 MB / 0.7701 GB, free: 13.49 MB / 0.6387 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001363/2.225, allocations: 0.7655 MB / 0.7708 GB, free: 12.73 MB / 0.6387 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0005566/2.225, allocations: 193.8 kB / 0.771 GB, free: 12.54 MB / 0.6387 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001464/2.227, allocations: 0.7988 MB / 0.7718 GB, free: 11.73 MB / 0.6387 GB Notification: Performance of pre-optimization done (n=129): time 4.038e-06/2.227, allocations: 0 / 0.7718 GB, free: 11.73 MB / 0.6387 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=214): time 0.16/2.387, allocations: 31.97 MB / 0.803 GB, free: 11.8 MB / 0.67 GB " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 4.034871059004217] Failed to read output from testmodel.py, exit status != 0: 2.72221418004483 2.73252963 0.538053706 Calling exit ...