/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Modelica_3.2.3_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_InverterDrive_res.mat --tempDir=temp_Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive_fmu --startTime=0 --stopTime=1.5 --stepSize=5e-05 --timeout=50 --tolerance=1e-06 Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_InverterDrive" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_InverterDrive" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_InverterDrive/model-5uq6anp9" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_InverterDrive" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive.fmu - startTime: 0.000000 - stopTime: 1.500000 - tolerance: 0.000001 - stepSize: 0.000050 info: maximum step size for 'model.root': 0.000050 info: Result file: Modelica_3.2.3_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_InverterDrive_res.mat (bufferSize=1) info: Variable model.root.Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive.terminalBox.terminalConnection will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | Solving non-linear system 809 failed at time=0.00787499134383567. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive" LOG_ASSERT | debug | Solving non-linear system 809 failed at time=0.00787499134383567. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pwm.svPWM.fire_p[3] LOG_ASSERT | debug | Solving non-linear system 809 failed at time=0.00787499134383567. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "model.root.Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive" [CVODE ERROR] CVode The right-hand side routine failed at the first call. error: [doStepCVODE] CVode failed with flag = -9 warning: Bad return code at time 0.007875 LOG_ASSERT | debug | Solving non-linear system 809 failed at time=0.00787499134383567. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] Modelica_3_2_3_Modelica_Electrical_Machines_Examples_AsynchronousInductionMachines_AIMC_InverterDrive/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pwm.svPWM.fire_p[3] error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 1 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 10 errors