Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001367/0.001367, allocations: 114.1 kB / 19.71 MB, free: 2.18 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001664/0.001664, allocations: 217.3 kB / 23.02 MB, free: 5.027 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.533/1.533, allocations: 207.6 MB / 233.8 MB, free: 9.996 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo): time 0.6328/0.6328, allocations: 114.3 MB / 400.4 MB, free: 16.3 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB,fileNamePrefix="Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB,fileNamePrefix="Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002449/0.002449, allocations: 69.06 kB / 0.5664 GB, free: 43.24 MB / 462.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1518/0.1542, allocations: 78.62 MB / 0.6432 GB, free: 14.84 MB / 494.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB): time 0.02759/0.1818, allocations: 22.25 MB / 0.6649 GB, free: 8.477 MB / 0.4981 GB Notification: Performance of NFInst.instExpressions: time 0.01781/0.1996, allocations: 10.03 MB / 0.6747 GB, free: 14.42 MB / 0.5137 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.005352/0.205, allocations: 127.2 kB / 0.6748 GB, free: 14.3 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Events/NodeFault.mo:24:3-24:107:writable] Warning: Connector nodeFault is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.008051/0.213, allocations: 1.945 MB / 0.6767 GB, free: 12.34 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.01383/0.2268, allocations: 2.413 MB / 0.6791 GB, free: 9.918 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/WT4ACurrentSource2015FOCB.mo:160:3-160:63:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/WT4ACurrentSource2015FOCB.mo:161:3-161:63:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:46:3-46:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:48:3-48:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:50:3-50:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:52:3-52:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:54:3-54:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:56:3-56:45:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/Wind/IEC/Neplan/BaseClasses/BaseWindNeplan.mo:58:3-58:46:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation transformer.terminal1.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation transformer.terminal1.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation transformer.terminal2.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation transformer.terminal2.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation transformer1.terminal1.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation transformer1.terminal1.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation transformer1.terminal2.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation transformer1.terminal2.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.02175/0.2486, allocations: 5.369 MB / 0.6843 GB, free: 4.598 MB / 0.5137 GB Notification: Performance of NFFlatten.flatten: time 0.02169/0.2703, allocations: 9.408 MB / 0.6935 GB, free: 11.17 MB / 0.5294 GB Notification: Performance of NFFlatten.resolveConnections: time 0.007027/0.2773, allocations: 2.162 MB / 0.6956 GB, free: 8.93 MB / 0.5294 GB Notification: Performance of NFEvalConstants.evaluate: time 0.006162/0.2835, allocations: 3.444 MB / 0.699 GB, free: 5.473 MB / 0.5294 GB Notification: Performance of NFSimplifyModel.simplify: time 0.005751/0.2892, allocations: 3.706 MB / 0.7026 GB, free: 1.75 MB / 0.5294 GB Notification: Performance of NFPackage.collectConstants: time 0.0029/0.2921, allocations: 1.008 MB / 0.7036 GB, free: 0.7422 MB / 0.5294 GB Notification: Performance of NFFlatten.collectFunctions: time 0.00285/0.295, allocations: 1.297 MB / 0.7049 GB, free: 15.45 MB / 0.545 GB Notification: Performance of NFScalarize.scalarize: time 0.00317/0.2981, allocations: 2.554 MB / 0.7074 GB, free: 12.88 MB / 0.545 GB Notification: Performance of NFVerifyModel.verify: time 0.006/0.3041, allocations: 4.262 MB / 0.7115 GB, free: 8.598 MB / 0.545 GB Notification: Performance of NFConvertDAE.convert: time 0.01948/0.3236, allocations: 14.27 MB / 0.7255 GB, free: 10.28 MB / 0.5606 GB Notification: Performance of FrontEnd - DAE generated: time 6.713e-06/0.3236, allocations: 0 / 0.7255 GB, free: 10.28 MB / 0.5606 GB Notification: Performance of FrontEnd: time 1.523e-06/0.3236, allocations: 0 / 0.7255 GB, free: 10.28 MB / 0.5606 GB Notification: Performance of Transformations before backend: time 0.0004274/0.3241, allocations: 4 kB / 0.7255 GB, free: 10.27 MB / 0.5606 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 1082 * Number of variables: 1082 Notification: Performance of Generate backend data structure: time 0.03001/0.3541, allocations: 10.63 MB / 0.7358 GB, free: 15.51 MB / 0.5762 GB Notification: Performance of prepare preOptimizeDAE: time 6.119e-05/0.3541, allocations: 16.03 kB / 0.7359 GB, free: 15.5 MB / 0.5762 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.001397/0.3555, allocations: 0.5914 MB / 0.7364 GB, free: 14.89 MB / 0.5762 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.009157/0.3647, allocations: 1.868 MB / 0.7383 GB, free: 13.02 MB / 0.5762 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01347/0.3781, allocations: 5.804 MB / 0.7439 GB, free: 7.16 MB / 0.5762 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.002526/0.3807, allocations: 2.8 MB / 0.7467 GB, free: 3.797 MB / 0.5762 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001656/0.3823, allocations: 439.9 kB / 0.7471 GB, free: 3.367 MB / 0.5762 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01378/0.3961, allocations: 5.683 MB / 0.7526 GB, free: 13.43 MB / 0.5919 GB Notification: Performance of preOpt findStateOrder (simulation): time 7.683e-05/0.3962, allocations: 11.92 kB / 0.7526 GB, free: 13.41 MB / 0.5919 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0005577/0.3967, allocations: 192 kB / 0.7528 GB, free: 13.23 MB / 0.5919 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 9.75e-05/0.3968, allocations: 108 kB / 0.7529 GB, free: 13.12 MB / 0.5919 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.01252/0.4094, allocations: 4.894 MB / 0.7577 GB, free: 8.223 MB / 0.5919 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.4094/0.8188, allocations: 26.49 MB / 0.7836 GB, free: 116.3 MB / 0.6075 GB Notification: Performance of preOpt comSubExp (simulation): time 0.01015/0.8289, allocations: 4.244 MB / 0.7877 GB, free: 116.2 MB / 0.6075 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.005284/0.8342, allocations: 2.266 MB / 0.7899 GB, free: 116.1 MB / 0.6075 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0003766/0.8346, allocations: 75.91 kB / 0.79 GB, free: 116.1 MB / 0.6075 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.007025/0.8416, allocations: 3.023 MB / 0.793 GB, free: 115.5 MB / 0.6075 GB Notification: Performance of pre-optimization done (n=400): time 1.591e-05/0.8416, allocations: 0 / 0.793 GB, free: 115.5 MB / 0.6075 GB Notification: Performance of matching and sorting (n=400): time 0.0607/0.9023, allocations: 16.71 MB / 0.8093 GB, free: 110 MB / 0.6075 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.000192/0.9025, allocations: 0.6804 MB / 0.81 GB, free: 109.3 MB / 0.6075 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01427/0.9168, allocations: 8.684 MB / 0.8184 GB, free: 105.2 MB / 0.6075 GB Notification: Performance of collectPreVariables (initialization): time 0.00109/0.9179, allocations: 127 kB / 0.8186 GB, free: 105.1 MB / 0.6075 GB Notification: Performance of collectInitialEqns (initialization): time 0.002918/0.9208, allocations: 3.452 MB / 0.8219 GB, free: 102.3 MB / 0.6075 GB Notification: Performance of collectInitialBindings (initialization): time 0.001624/0.9224, allocations: 1.318 MB / 0.8232 GB, free: 101 MB / 0.6075 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.001387/0.9238, allocations: 0.8725 MB / 0.8241 GB, free: 100.1 MB / 0.6075 GB Notification: Performance of setup shared object (initialization): time 4.692e-05/0.9239, allocations: 301.1 kB / 0.8243 GB, free: 99.82 MB / 0.6075 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.004157/0.928, allocations: 2.325 MB / 0.8266 GB, free: 97.48 MB / 0.6075 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.004934/0.933, allocations: 3.277 MB / 0.8298 GB, free: 93.88 MB / 0.6075 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.02544/0.9584, allocations: 10.87 MB / 0.8404 GB, free: 82.74 MB / 0.6075 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.532e-05/0.9584, allocations: 4 kB / 0.8404 GB, free: 82.74 MB / 0.6075 GB Notification: Performance of matching and sorting (n=624) (initialization): time 0.01997/0.9784, allocations: 8.25 MB / 0.8485 GB, free: 74.4 MB / 0.6075 GB Notification: Performance of prepare postOptimizeDAE: time 8.429e-05/0.9785, allocations: 76.02 kB / 0.8486 GB, free: 74.31 MB / 0.6075 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 2.891e-05/0.9785, allocations: 28.12 kB / 0.8486 GB, free: 74.29 MB / 0.6075 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.006269/0.9848, allocations: 2.583 MB / 0.8511 GB, free: 71.69 MB / 0.6075 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003173/0.988, allocations: 0.7487 MB / 0.8519 GB, free: 70.94 MB / 0.6075 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0331/1.021, allocations: 22.4 MB / 0.8737 GB, free: 48.1 MB / 0.6075 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.005536/1.027, allocations: 0.6102 MB / 0.8743 GB, free: 47.49 MB / 0.6075 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0008686/1.027, allocations: 172 kB / 0.8745 GB, free: 47.32 MB / 0.6075 GB Warning: Assuming fixed start value for the following 28 variables: transformer.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line1.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) wT4ACurrentSource.wT4Injector.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = wT4ACurrentSource.wT4Injector.State0 fixed = true ) \"Injector connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer.running.value:DISCRETE(flow=false start = transformer.Running0 fixed = true ) type: Boolean transformer1.running.value:DISCRETE(flow=false start = transformer1.Running0 fixed = true ) type: Boolean line.running.value:DISCRETE(flow=false start = line.Running0 fixed = true ) type: Boolean line1.running.value:DISCRETE(flow=false start = line1.Running0 fixed = true ) type: Boolean line2.running.value:DISCRETE(flow=false start = line2.Running0 fixed = true ) type: Boolean line3.running.value:DISCRETE(flow=false start = line3.Running0 fixed = true ) type: Boolean line4.running.value:DISCRETE(flow=false start = line4.Running0 fixed = true ) type: Boolean wT4ACurrentSource.wT4Injector.running.value:DISCRETE(flow=false start = wT4ACurrentSource.wT4Injector.Running0 fixed = true ) type: Boolean wT4ACurrentSource.pll.fixedBooleanDelay1.y:DISCRETE(flow=false start = wT4ACurrentSource.pll.fixedBooleanDelay1.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4ACurrentSource.pll.fixedBooleanDelay.y:DISCRETE(flow=false start = wT4ACurrentSource.pll.fixedBooleanDelay.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4ACurrentSource.control4A.currentLimiter.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.currentLimiter.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.control4A.pControl4A.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.pControl4A.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.control4A.qControl.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.qControl.vDrop.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.control4A.qControl.firstOrder1.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.qControl.firstOrder1.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.derivative.x:VARIABLE(start = wT4ACurrentSource.gridProtection.ufMeasurement.derivative.x_start fixed = true ) \"State of block\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder1.y:VARIABLE(flow=false start = wT4ACurrentSource.gridProtection.ufMeasurement.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder2.y:VARIABLE(flow=false start = wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder2.y_start fixed = true ) \"Connector of Real output signal\" type: Real nodeFault.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean nodeFault1.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.008401/1.036, allocations: 3.968 MB / 0.8784 GB, free: 43.35 MB / 0.6075 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.005339/1.041, allocations: 3.25 MB / 0.8815 GB, free: 39.76 MB / 0.6075 GB Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.0257/1.067, allocations: 10.83 MB / 0.8921 GB, free: 28.51 MB / 0.6075 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 2.241e-05/1.067, allocations: 8 kB / 0.8921 GB, free: 28.5 MB / 0.6075 GB Notification: Performance of matching and sorting (n=624) (initialization_lambda0): time 0.0202/1.087, allocations: 8.208 MB / 0.9001 GB, free: 20.17 MB / 0.6075 GB Notification: Performance of prepare postOptimizeDAE: time 8.415e-05/1.087, allocations: 87.31 kB / 0.9002 GB, free: 20.07 MB / 0.6075 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 3.051e-05/1.087, allocations: 20 kB / 0.9002 GB, free: 20.05 MB / 0.6075 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.006319/1.094, allocations: 2.583 MB / 0.9028 GB, free: 17.46 MB / 0.6075 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003255/1.097, allocations: 0.7526 MB / 0.9035 GB, free: 16.7 MB / 0.6075 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03591/1.133, allocations: 22.4 MB / 0.9254 GB, free: 9.871 MB / 0.6231 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.00554/1.138, allocations: 0.5522 MB / 0.9259 GB, free: 9.316 MB / 0.6231 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.000932/1.139, allocations: 176 kB / 0.9261 GB, free: 9.145 MB / 0.6231 GB Warning: Assuming fixed start value for the following 28 variables: transformer.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line1.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) wT4ACurrentSource.wT4Injector.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = wT4ACurrentSource.wT4Injector.State0 fixed = true ) \"Injector connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer.running.value:DISCRETE(flow=false start = transformer.Running0 fixed = true ) type: Boolean transformer1.running.value:DISCRETE(flow=false start = transformer1.Running0 fixed = true ) type: Boolean line.running.value:DISCRETE(flow=false start = line.Running0 fixed = true ) type: Boolean line1.running.value:DISCRETE(flow=false start = line1.Running0 fixed = true ) type: Boolean line2.running.value:DISCRETE(flow=false start = line2.Running0 fixed = true ) type: Boolean line3.running.value:DISCRETE(flow=false start = line3.Running0 fixed = true ) type: Boolean line4.running.value:DISCRETE(flow=false start = line4.Running0 fixed = true ) type: Boolean wT4ACurrentSource.wT4Injector.running.value:DISCRETE(flow=false start = wT4ACurrentSource.wT4Injector.Running0 fixed = true ) type: Boolean wT4ACurrentSource.pll.fixedBooleanDelay1.y:DISCRETE(flow=false start = wT4ACurrentSource.pll.fixedBooleanDelay1.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4ACurrentSource.pll.fixedBooleanDelay.y:DISCRETE(flow=false start = wT4ACurrentSource.pll.fixedBooleanDelay.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4ACurrentSource.control4A.currentLimiter.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.currentLimiter.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.control4A.pControl4A.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.pControl4A.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.control4A.qControl.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.qControl.vDrop.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.control4A.qControl.firstOrder1.y:VARIABLE(flow=false start = wT4ACurrentSource.control4A.qControl.firstOrder1.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.derivative.x:VARIABLE(start = wT4ACurrentSource.gridProtection.ufMeasurement.derivative.x_start fixed = true ) \"State of block\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder.y:VARIABLE(flow=false start = wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder1.y:VARIABLE(flow=false start = wT4ACurrentSource.gridProtection.ufMeasurement.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder2.y:VARIABLE(flow=false start = wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder2.y_start fixed = true ) \"Connector of Real output signal\" type: Real nodeFault.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean nodeFault1.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 85 * Number of states: 0 () * Number of discrete variables: 147 ($PRE.transformer.state,transformer.state,$PRE.transformer1.state,transformer1.state,$PRE.line.state,line.state,$PRE.line1.state,line1.state,$PRE.line2.state,line2.state,$PRE.line3.state,line3.state,$PRE.line4.state,line4.state,$PRE.wT4ACurrentSource.wT4Injector.state,wT4ACurrentSource.wT4Injector.state,$whenCondition4,$whenCondition5,$whenCondition2,$whenCondition3,transformer1.switchOffSignal2.value,transformer1.switchOffSignal1.value,transformer.switchOffSignal2.value,transformer.switchOffSignal1.value,line4.switchOffSignal2.value,line4.switchOffSignal1.value,line3.switchOffSignal2.value,line3.switchOffSignal1.value,line2.switchOffSignal2.value,line2.switchOffSignal1.value,line1.switchOffSignal2.value,line1.switchOffSignal1.value,line.switchOffSignal2.value,line.switchOffSignal1.value,wT4ACurrentSource.wT4Injector.switchOffSignal3.value,wT4ACurrentSource.wT4Injector.switchOffSignal2.value,wT4ACurrentSource.wT4Injector.switchOffSignal1.value,$PRE.transformer.running.value,$PRE.transformer1.running.value,$PRE.line.running.value,$PRE.line1.running.value,$PRE.line2.running.value,$PRE.line3.running.value,$PRE.line4.running.value,$PRE.wT4ACurrentSource.wT4Injector.running.value,$PRE.wT4ACurrentSource.pll.fixedBooleanDelay1.y,$PRE.wT4ACurrentSource.pll.fixedBooleanDelay.y,$PRE.nodeFault.nodeFault.value,$PRE.nodeFault1.nodeFault.value,$PRE.omegaRefPu.count,$PRE.omegaRefPu.T_start,$PRE.wT4ACurrentSource.gridProtection.pre1.u,$PRE.wT4ACurrentSource.gridProtection.timer3.entryTime,$PRE.wT4ACurrentSource.gridProtection.timer2.entryTime,$PRE.wT4ACurrentSource.gridProtection.timer1.entryTime,$PRE.wT4ACurrentSource.gridProtection.timer.entryTime,$PRE.wT4ACurrentSource.control4A.qControl.delayFlag.timer.entryTime,wT4ACurrentSource.control4A.currentLimiter.product1.u[2],omegaRefPu.count,omegaRefPu.T_start,nodeFault1.nodeFault.value,nodeFault.nodeFault.value,wT4ACurrentSource.gridProtection.pre1.u,wT4ACurrentSource.gridProtection.or1.u[5],wT4ACurrentSource.gridProtection.or1.u[4],wT4ACurrentSource.gridProtection.or1.u[3],wT4ACurrentSource.gridProtection.or1.u[2],wT4ACurrentSource.gridProtection.or1.u[1],wT4ACurrentSource.gridProtection.timer3.entryTime,wT4ACurrentSource.gridProtection.timer2.entryTime,wT4ACurrentSource.gridProtection.timer1.entryTime,wT4ACurrentSource.gridProtection.lessEqual3.y,wT4ACurrentSource.gridProtection.lessEqual2.y,wT4ACurrentSource.gridProtection.lessEqual1.y,wT4ACurrentSource.gridProtection.lessEqual.y,wT4ACurrentSource.gridProtection.timer.entryTime,wT4ACurrentSource.control4A.qLimiter.integerToBoolean.y,wT4ACurrentSource.control4A.qControl.fUvrt,wT4ACurrentSource.control4A.qControl.greaterEqualThreshold.y,wT4ACurrentSource.control4A.qControl.delayFlag.booleanToInteger.y,wT4ACurrentSource.control4A.qControl.delayFlag.switch1.y,wT4ACurrentSource.control4A.qControl.delayFlag.less1.y,wT4ACurrentSource.control4A.qControl.delayFlag.timer.entryTime,wT4ACurrentSource.control4A.qControl.delayFlag.fI,wT4ACurrentSource.control4A.currentLimiter.greater.y,wT4ACurrentSource.control4A.currentLimiter.product1.y,wT4ACurrentSource.pll.fixedBooleanDelay.y,wT4ACurrentSource.pll.fixedBooleanDelay1.y,wT4ACurrentSource.pll.lessThreshold1.y,wT4ACurrentSource.pll.lessThreshold.y,wT4ACurrentSource.wT4Injector.running.value,line4.running.value,line3.running.value,line2.running.value,line1.running.value,line.running.value,transformer1.running.value,transformer.running.value,$whenCondition1,$whenCondition6,$whenCondition7,$whenCondition8,$whenCondition9,$whenCondition10,$whenCondition12,$whenCondition11,$whenCondition14,$whenCondition13,$whenCondition15,$whenCondition17,$whenCondition16,$whenCondition18,$whenCondition20,$whenCondition19,$whenCondition21,$whenCondition23,$whenCondition22,$whenCondition24,$whenCondition26,$whenCondition25,$whenCondition27,$whenCondition29,$whenCondition28,$whenCondition30,$whenCondition32,$whenCondition31,$whenCondition33,$whenCondition35,$whenCondition34,$whenCondition36,$whenCondition38,$whenCondition37,$whenCondition40,$whenCondition39,$whenCondition42,$whenCondition41,wT4ACurrentSource.gridProtection.ufMeasurement.rampLimiter.integrator.local_reset,wT4ACurrentSource.control4A.qLimiter.absLimRateLimFirstOrderFreeze1.integrator.local_reset,wT4ACurrentSource.control4A.qLimiter.absLimRateLimFirstOrderFreeze.integrator.local_reset,wT4ACurrentSource.control4A.qControl.absLimRateLimFeedthroughFreeze.rampLimiter.integrator.local_reset,wT4ACurrentSource.control4A.qControl.absLimRateLimFirstOrderFreeze.integrator.local_reset,wT4ACurrentSource.control4A.qControl.antiWindupIntegrator1.integrator.local_reset,wT4ACurrentSource.control4A.qControl.antiWindupIntegrator.integrator.local_reset,wT4ACurrentSource.control4A.pControl4A.absLimRateLimFirstOrderAntiWindup.integrator.local_reset,wT4ACurrentSource.pll.absLimRateLimFirstOrderFreeze.integrator.local_reset,wT4ACurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup1.integrator.local_reset,wT4ACurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup.integrator.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (500): * Single equations (assignments): 494 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 4 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 3 systems {(1,1,100.0%), (2,2,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(30,75)} Notification: Performance of prepare postOptimizeDAE: time 0.00162/1.141, allocations: 0.6483 MB / 0.9267 GB, free: 8.477 MB / 0.6231 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.00231/1.143, allocations: 0.7878 MB / 0.9275 GB, free: 7.684 MB / 0.6231 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01558/1.159, allocations: 6.24 MB / 0.9336 GB, free: 1.398 MB / 0.6231 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 4.295e-05/1.159, allocations: 40 kB / 0.9336 GB, free: 1.359 MB / 0.6231 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.376e-05/1.159, allocations: 0 / 0.9336 GB, free: 1.359 MB / 0.6231 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 6.294e-05/1.159, allocations: 19.92 kB / 0.9336 GB, free: 1.34 MB / 0.6231 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.03348/1.192, allocations: 15.08 MB / 0.9484 GB, free: 2.273 MB / 0.6387 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 2.273e-05/1.192, allocations: 4 kB / 0.9484 GB, free: 2.27 MB / 0.6387 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.002295/1.195, allocations: 491.2 kB / 0.9488 GB, free: 1.789 MB / 0.6387 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.006905/1.202, allocations: 2.39 MB / 0.9512 GB, free: 15.39 MB / 0.6544 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0005645/1.202, allocations: 95.95 kB / 0.9513 GB, free: 15.3 MB / 0.6544 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.03763/1.24, allocations: 19.58 MB / 0.9704 GB, free: 11.49 MB / 0.67 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.324e-06/1.24, allocations: 96 / 0.9704 GB, free: 11.49 MB / 0.67 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.0259/1.266, allocations: 10.37 MB / 0.9805 GB, free: 1.047 MB / 0.67 GB Notification: Performance of postOpt removeConstants (simulation): time 0.002566/1.268, allocations: 0.9787 MB / 0.9815 GB, free: 64 kB / 0.67 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001151/1.269, allocations: 92.73 kB / 0.9815 GB, free: 15.97 MB / 0.6856 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.003041/1.272, allocations: 335.5 kB / 0.9819 GB, free: 15.64 MB / 0.6856 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001207/1.274, allocations: 423.1 kB / 0.9823 GB, free: 15.23 MB / 0.6856 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0003251/1.274, allocations: 135.9 kB / 0.9824 GB, free: 15.09 MB / 0.6856 GB Notification: Performance of sorting global known variables: time 0.01203/1.286, allocations: 5.942 MB / 0.9882 GB, free: 9.168 MB / 0.6856 GB Notification: Performance of sort global known variables: time 2.61e-07/1.286, allocations: 0 / 0.9882 GB, free: 9.168 MB / 0.6856 GB Notification: Performance of remove unused functions: time 0.01352/1.299, allocations: 2.718 MB / 0.9909 GB, free: 6.445 MB / 0.6856 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 6 * Number of states: 19 (wT4ACurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup.integrator.y,wT4ACurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup1.integrator.y,wT4ACurrentSource.pll.absLimRateLimFirstOrderFreeze.integrator.y,wT4ACurrentSource.control4A.currentLimiter.firstOrder.y,wT4ACurrentSource.control4A.pControl4A.absLimRateLimFirstOrderAntiWindup.integrator.y,wT4ACurrentSource.control4A.pControl4A.firstOrder.y,wT4ACurrentSource.control4A.qControl.antiWindupIntegrator.integrator.y,wT4ACurrentSource.control4A.qControl.antiWindupIntegrator1.integrator.y,wT4ACurrentSource.control4A.qControl.absLimRateLimFirstOrderFreeze.integrator.y,wT4ACurrentSource.control4A.qControl.absLimRateLimFeedthroughFreeze.rampLimiter.integrator.y,wT4ACurrentSource.control4A.qControl.firstOrder.y,wT4ACurrentSource.control4A.qControl.firstOrder1.y,wT4ACurrentSource.control4A.qLimiter.absLimRateLimFirstOrderFreeze.integrator.y,wT4ACurrentSource.control4A.qLimiter.absLimRateLimFirstOrderFreeze1.integrator.y,wT4ACurrentSource.gridProtection.ufMeasurement.derivative.x,wT4ACurrentSource.gridProtection.ufMeasurement.rampLimiter.integrator.y,wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder.y,wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder1.y,wT4ACurrentSource.gridProtection.ufMeasurement.firstOrder2.y) * Number of discrete variables: 90 (wT4ACurrentSource.control4A.qControl.delayFlag.fI,wT4ACurrentSource.gridProtection.or1.u[1],wT4ACurrentSource.gridProtection.or1.u[2],wT4ACurrentSource.gridProtection.or1.u[3],wT4ACurrentSource.gridProtection.or1.u[4],wT4ACurrentSource.gridProtection.lessEqual.y,wT4ACurrentSource.gridProtection.lessEqual1.y,wT4ACurrentSource.gridProtection.lessEqual2.y,wT4ACurrentSource.gridProtection.lessEqual3.y,$whenCondition41,$whenCondition42,$whenCondition39,$whenCondition40,$whenCondition37,$whenCondition38,$whenCondition36,$whenCondition34,$whenCondition35,$whenCondition33,$whenCondition31,$whenCondition32,$whenCondition30,$whenCondition28,$whenCondition29,$whenCondition27,$whenCondition25,$whenCondition26,$whenCondition24,$whenCondition22,$whenCondition23,$whenCondition21,$whenCondition19,$whenCondition20,$whenCondition18,$whenCondition16,$whenCondition17,$whenCondition15,$whenCondition13,$whenCondition14,$whenCondition11,$whenCondition12,$whenCondition10,$whenCondition9,$whenCondition8,$whenCondition7,$whenCondition6,$whenCondition4,$whenCondition5,$whenCondition2,$whenCondition3,$whenCondition1,transformer.running.value,transformer.state,transformer1.running.value,transformer1.state,line.running.value,line.state,line1.running.value,line1.state,line2.running.value,line2.state,line3.running.value,line3.state,line4.running.value,line4.state,wT4ACurrentSource.wT4Injector.running.value,wT4ACurrentSource.wT4Injector.state,wT4ACurrentSource.pll.lessThreshold.y,wT4ACurrentSource.pll.lessThreshold1.y,wT4ACurrentSource.pll.fixedBooleanDelay1.y,wT4ACurrentSource.pll.fixedBooleanDelay.y,wT4ACurrentSource.control4A.currentLimiter.product1.y,wT4ACurrentSource.control4A.currentLimiter.greater.y,wT4ACurrentSource.control4A.qControl.delayFlag.timer.entryTime,wT4ACurrentSource.control4A.qControl.delayFlag.less1.y,wT4ACurrentSource.control4A.qControl.delayFlag.switch1.y,wT4ACurrentSource.control4A.qControl.delayFlag.booleanToInteger.y,wT4ACurrentSource.control4A.qControl.greaterEqualThreshold.y,wT4ACurrentSource.control4A.qControl.fUvrt,wT4ACurrentSource.control4A.qLimiter.integerToBoolean.y,wT4ACurrentSource.gridProtection.timer.entryTime,wT4ACurrentSource.gridProtection.timer1.entryTime,wT4ACurrentSource.gridProtection.timer2.entryTime,wT4ACurrentSource.gridProtection.timer3.entryTime,wT4ACurrentSource.gridProtection.or1.u[5],wT4ACurrentSource.gridProtection.pre1.u,nodeFault.nodeFault.value,nodeFault1.nodeFault.value,omegaRefPu.T_start,omegaRefPu.count) * Number of discrete states: 10 (transformer.running.value,transformer1.running.value,line.running.value,line1.running.value,line2.running.value,line3.running.value,line4.running.value,wT4ACurrentSource.wT4Injector.running.value,omegaRefPu.count,wT4ACurrentSource.gridProtection.pre1.u) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (295): * Single equations (assignments): 266 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 27 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 2 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(2,2,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(30,77)} Notification: Performance of Backend phase and start with SimCode phase: time 0.03009/1.33, allocations: 11.39 MB / 1.002 GB, free: 11.11 MB / 0.7012 GB Notification: Performance of simCode: created initialization part: time 0.02832/1.358, allocations: 11.17 MB / 1.013 GB, free: 15.76 MB / 0.7169 GB Notification: Performance of simCode: created event and clocks part: time 2.206e-05/1.358, allocations: 448 / 1.013 GB, free: 15.76 MB / 0.7169 GB Notification: Performance of simCode: created simulation system equations: time 0.01182/1.37, allocations: 3.855 MB / 1.017 GB, free: 11.89 MB / 0.7169 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.008006/1.378, allocations: 1.115 MB / 1.018 GB, free: 10.79 MB / 0.7169 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.5094/1.887, allocations: 70.7 MB / 1.087 GB, free: 252.5 MB / 0.7637 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.004993/1.892, allocations: 3.696 MB / 1.09 GB, free: 251.6 MB / 0.7637 GB Notification: Performance of simCode: alias equations: time 0.003727/1.896, allocations: 1.036 MB / 1.091 GB, free: 251.6 MB / 0.7637 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.003882/1.9, allocations: 3.293 MB / 1.095 GB, free: 251.6 MB / 0.7637 GB Notification: Performance of SimCode: time 8.51e-07/1.9, allocations: 0 / 1.095 GB, free: 251.6 MB / 0.7637 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.4522/2.352, allocations: 195.7 MB / 1.286 GB, free: 79.37 MB / 0.7637 GB Error: Error building simulator. Build log: cmd: cd '522.fmutmp/sources/' && mkdir build_cmake_static && cd build_cmake_static && cmake -DCMAKE_BUILD_TYPE=Release -DCMAKE_C_COMPILER='clang' .. && cmake --build . --parallel -j1 --target install && cd .. && rm -rf build_cmake_static -- The C compiler identification is Clang 14.0.0 -- Detecting C compiler ABI info -- Detecting C compiler ABI info - done -- Check for working C compiler: /usr/bin/clang - skipped -- Detecting C compile features -- Detecting C compile features - done -- FMI2 include directory: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB/522.fmutmp/sources/fmi -- Looking for pthread.h -- Looking for pthread.h - found -- Performing Test CMAKE_HAVE_LIBC_PTHREAD -- Performing Test CMAKE_HAVE_LIBC_PTHREAD - Success -- Found Threads: TRUE -- Building for FMI platform linux64 -- Install directory: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB/522.fmutmp/sources/../binaries/linux64 -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaStandardTables.a -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaIO.a -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaMatIO.a -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libzlib.a -- CVODE: Not linked -- Not using FMI2_FUNCTION_PREFIX -- Installing dynamic dependencies from list: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaStandardTables.a;/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaIO.a;/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaMatIO.a;/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libzlib.a -- Configuring done -- Generating done -- Build files have been written to: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB/522.fmutmp/sources/build_cmake_static [ 0%] Building C object CMakeFiles/522.dir/external_solvers/F77_aloc.c.o [ 1%] Building C object CMakeFiles/522.dir/external_solvers/dgemm.c.o [ 2%] Building C object CMakeFiles/522.dir/external_solvers/dgemv.c.o [ 3%] Building C object CMakeFiles/522.dir/external_solvers/dger.c.o [ 4%] Building C object CMakeFiles/522.dir/external_solvers/dgesv.c.o [ 5%] Building C object CMakeFiles/522.dir/external_solvers/dgetf2.c.o [ 5%] Building C object CMakeFiles/522.dir/external_solvers/dgetrf.c.o [ 6%] Building C object CMakeFiles/522.dir/external_solvers/dgetri.c.o [ 7%] Building C object CMakeFiles/522.dir/external_solvers/dgetrs.c.o [ 8%] Building C object CMakeFiles/522.dir/external_solvers/dlamch.c.o [ 9%] Building C object CMakeFiles/522.dir/external_solvers/dlaswp.c.o [ 10%] Building C object CMakeFiles/522.dir/external_solvers/dogleg_.c.o [ 11%] Building C object CMakeFiles/522.dir/external_solvers/dpmpar_.c.o [ 11%] Building C object CMakeFiles/522.dir/external_solvers/dscal.c.o [ 12%] Building C object CMakeFiles/522.dir/external_solvers/dswap.c.o [ 13%] Building C object CMakeFiles/522.dir/external_solvers/dtrmm.c.o [ 14%] Building C object CMakeFiles/522.dir/external_solvers/dtrmv.c.o [ 15%] Building C object CMakeFiles/522.dir/external_solvers/dtrsm.c.o [ 16%] Building C object CMakeFiles/522.dir/external_solvers/dtrti2.c.o [ 17%] Building C object CMakeFiles/522.dir/external_solvers/dtrtri.c.o [ 17%] Building C object CMakeFiles/522.dir/external_solvers/enorm_.c.o [ 18%] Building C object CMakeFiles/522.dir/external_solvers/exit_.c.o [ 19%] Building C object CMakeFiles/522.dir/external_solvers/hybrj_.c.o [ 20%] Building C object CMakeFiles/522.dir/external_solvers/i_nint.c.o [ 21%] Building C object CMakeFiles/522.dir/external_solvers/idamax.c.o [ 22%] Building C object CMakeFiles/522.dir/external_solvers/ieeeck.c.o [ 23%] Building C object CMakeFiles/522.dir/external_solvers/ilaenv.c.o [ 23%] Building C object CMakeFiles/522.dir/external_solvers/iparmq.c.o [ 24%] Building C object CMakeFiles/522.dir/external_solvers/lsame.c.o [ 25%] Building C object CMakeFiles/522.dir/external_solvers/pow_di.c.o [ 26%] Building C object CMakeFiles/522.dir/external_solvers/qform_.c.o [ 27%] Building C object CMakeFiles/522.dir/external_solvers/qrfac_.c.o [ 28%] Building C object CMakeFiles/522.dir/external_solvers/r1mpyq_.c.o [ 29%] Building C object CMakeFiles/522.dir/external_solvers/r1updt_.c.o [ 29%] Building C object CMakeFiles/522.dir/external_solvers/s_cat.c.o [ 30%] Building C object CMakeFiles/522.dir/external_solvers/s_cmp.c.o [ 31%] Building C object CMakeFiles/522.dir/external_solvers/s_copy.c.o [ 32%] Building C object CMakeFiles/522.dir/external_solvers/xerbla.c.o [ 33%] Building C object CMakeFiles/522.dir/gc/memory_pool.c.o [ 34%] Building C object CMakeFiles/522.dir/gc/omc_gc.c.o [ 35%] Building C object CMakeFiles/522.dir/math-support/pivot.c.o [ 35%] Building C object CMakeFiles/522.dir/meta/meta_modelica_catch.c.o [ 36%] Building C object CMakeFiles/522.dir/simulation/jacobian_util.c.o [ 37%] Building C object CMakeFiles/522.dir/simulation/omc_simulation_util.c.o [ 38%] Building C object CMakeFiles/522.dir/simulation/options.c.o [ 39%] Building C object CMakeFiles/522.dir/simulation/simulation_info_json.c.o [ 40%] Building C object CMakeFiles/522.dir/simulation/simulation_omc_assert.c.o [ 41%] Building C object CMakeFiles/522.dir/simulation/solver/delay.c.o [ 41%] Building C object CMakeFiles/522.dir/simulation/solver/fmi_events.c.o [ 42%] Building C object CMakeFiles/522.dir/simulation/solver/initialization/initialization.c.o [ 43%] Building C object CMakeFiles/522.dir/simulation/solver/linearSolverLapack.c.o [ 44%] Building C object CMakeFiles/522.dir/simulation/solver/linearSolverTotalPivot.c.o [ 45%] Building C object CMakeFiles/522.dir/simulation/solver/linearSystem.c.o [ 46%] Building C object CMakeFiles/522.dir/simulation/solver/model_help.c.o [ 47%] Building C object CMakeFiles/522.dir/simulation/solver/nonlinearSolverHomotopy.c.o [ 47%] Building C object CMakeFiles/522.dir/simulation/solver/nonlinearSolverHybrd.c.o [ 48%] Building C object CMakeFiles/522.dir/simulation/solver/nonlinearSystem.c.o [ 49%] Building C object CMakeFiles/522.dir/simulation/solver/nonlinearValuesList.c.o [ 50%] Building C object CMakeFiles/522.dir/simulation/solver/omc_math.c.o [ 51%] Building C object CMakeFiles/522.dir/simulation/solver/spatialDistribution.c.o [ 52%] Building C object CMakeFiles/522.dir/simulation/solver/stateset.c.o [ 52%] Building C object CMakeFiles/522.dir/simulation/solver/synchronous.c.o [ 53%] Building C object CMakeFiles/522.dir/util/ModelicaUtilities.c.o [ 54%] Building C object CMakeFiles/522.dir/util/base_array.c.o [ 55%] Building C object CMakeFiles/522.dir/util/boolean_array.c.o [ 56%] Building C object CMakeFiles/522.dir/util/context.c.o [ 57%] Building C object CMakeFiles/522.dir/util/division.c.o [ 58%] Building C object CMakeFiles/522.dir/util/doubleEndedList.c.o [ 58%] Building C object CMakeFiles/522.dir/util/generic_array.c.o [ 59%] Building C object CMakeFiles/522.dir/util/index_spec.c.o [ 60%] Building C object CMakeFiles/522.dir/util/integer_array.c.o [ 61%] Building C object CMakeFiles/522.dir/util/list.c.o [ 62%] Building C object CMakeFiles/522.dir/util/modelica_string.c.o [ 63%] Building C object CMakeFiles/522.dir/util/modelica_string_lit.c.o [ 64%] Building C object CMakeFiles/522.dir/util/omc_error.c.o [ 64%] Building C object CMakeFiles/522.dir/util/omc_file.c.o [ 65%] Building C object CMakeFiles/522.dir/util/omc_init.c.o [ 66%] Building C object CMakeFiles/522.dir/util/omc_mmap.c.o [ 67%] Building C object CMakeFiles/522.dir/util/omc_msvc.c.o [ 68%] Building C object CMakeFiles/522.dir/util/omc_numbers.c.o [ 69%] Building C object CMakeFiles/522.dir/util/parallel_helper.c.o [ 70%] Building C object CMakeFiles/522.dir/util/rational.c.o [ 70%] Building C object CMakeFiles/522.dir/util/real_array.c.o [ 71%] Building C object CMakeFiles/522.dir/util/ringbuffer.c.o [ 72%] Building C object CMakeFiles/522.dir/util/simulation_options.c.o [ 73%] Building C object CMakeFiles/522.dir/util/string_array.c.o [ 74%] Building C object CMakeFiles/522.dir/util/utility.c.o [ 75%] Building C object CMakeFiles/522.dir/util/varinfo.c.o [ 76%] Building C object CMakeFiles/522.dir/Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB.c.o /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB/522.fmutmp/sources/Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB.c:8:10: fatal error: 'Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB_16dae.h' file not found #include \"Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB_16dae.h\" ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 1 error generated. gmake[2]: *** [CMakeFiles/522.dir/build.make:1308: CMakeFiles/522.dir/Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4ACurrentSource2015FOCB.c.o] Error 1 gmake[1]: *** [CMakeFiles/Makefile2:84: CMakeFiles/522.dir/all] Error 2 gmake: *** [Makefile:136: all] Error 2 " [Timeout remaining time 647] [Calling sys.exit(0), Time elapsed: 16.695135772926733] Failed to read output from testmodel.py, exit status != 0: 13.231489298166707 13.246207194 12.9190103 Calling exit ...