Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.GridForming.GridForming.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001281/0.001281, allocations: 110.3 kB / 19.72 MB, free: 2.188 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001507/0.001507, allocations: 215.9 kB / 23.03 MB, free: 5.039 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.447/1.447, allocations: 207.6 MB / 233.8 MB, free: 9.992 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo): time 0.6722/0.6722, allocations: 114.3 MB / 400.4 MB, free: 16.32 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.GridForming.GridForming,fileNamePrefix="Dynawo_dev_Dynawo_Examples_GridForming_GridForming",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.GridForming.GridForming,fileNamePrefix="Dynawo_dev_Dynawo_Examples_GridForming_GridForming",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002454/0.002454, allocations: 79.91 kB / 0.5648 GB, free: 44.03 MB / 462.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1238/0.1262, allocations: 78.64 MB / 0.6416 GB, free: 472 kB / 478.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.GridForming.GridForming): time 0.02001/0.1462, allocations: 17.05 MB / 0.6583 GB, free: 15.33 MB / 0.4981 GB Notification: Performance of NFInst.instExpressions: time 0.01344/0.1597, allocations: 6.234 MB / 0.6644 GB, free: 9.066 MB / 0.4981 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.003246/0.1629, allocations: 67.62 kB / 0.6644 GB, free: 9 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Events/NodeFault.mo:24:3-24:107:writable] Warning: Connector nodeFault is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.003035/0.166, allocations: 0.7301 MB / 0.6651 GB, free: 8.277 MB / 0.4981 GB Notification: Performance of NFTyping.typeBindings: time 0.004611/0.1706, allocations: 1.051 MB / 0.6662 GB, free: 7.219 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:494:3-494:50:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:497:3-497:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:499:3-499:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:501:3-501:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:503:3-503:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:505:3-505:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:507:3-507:41:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:508:3-508:41:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:510:3-510:41:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:511:3-511:41:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:513:3-513:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/GridForming/GridForming.mo:514:3-514:42:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv250.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv250.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv500.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv500.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv1000.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv1000.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBeta.mo:24:5-30:11:writable] Warning: In relation Load.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBeta.mo:24:5-30:11:writable] Warning: In relation Load.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.007022/0.1776, allocations: 2.486 MB / 0.6686 GB, free: 4.73 MB / 0.4981 GB Notification: Performance of NFFlatten.flatten: time 0.009579/0.1872, allocations: 5.894 MB / 0.6743 GB, free: 14.82 MB / 0.5137 GB Notification: Performance of NFFlatten.resolveConnections: time 0.003695/0.1909, allocations: 1.459 MB / 0.6758 GB, free: 13.29 MB / 0.5137 GB Notification: Performance of NFEvalConstants.evaluate: time 0.004325/0.1952, allocations: 2.277 MB / 0.678 GB, free: 11.01 MB / 0.5137 GB Notification: Performance of NFSimplifyModel.simplify: time 0.004153/0.1993, allocations: 2.703 MB / 0.6806 GB, free: 8.293 MB / 0.5137 GB Notification: Performance of NFPackage.collectConstants: time 0.001713/0.2011, allocations: 0.5859 MB / 0.6812 GB, free: 7.707 MB / 0.5137 GB Notification: Performance of NFFlatten.collectFunctions: time 0.001956/0.203, allocations: 0.7421 MB / 0.6819 GB, free: 6.965 MB / 0.5137 GB Notification: Performance of NFScalarize.scalarize: time 0.001699/0.2047, allocations: 1.226 MB / 0.6831 GB, free: 5.734 MB / 0.5137 GB Notification: Performance of NFVerifyModel.verify: time 0.004018/0.2087, allocations: 2.533 MB / 0.6856 GB, free: 3.188 MB / 0.5137 GB Notification: Performance of NFConvertDAE.convert: time 0.01018/0.2189, allocations: 6.7 MB / 0.6921 GB, free: 12.46 MB / 0.5294 GB Notification: Performance of FrontEnd - DAE generated: time 6.603e-06/0.2189, allocations: 0 / 0.6921 GB, free: 12.46 MB / 0.5294 GB Notification: Performance of FrontEnd: time 1.713e-06/0.2189, allocations: 4 kB / 0.6921 GB, free: 12.46 MB / 0.5294 GB Notification: Performance of Transformations before backend: time 0.0002557/0.2192, allocations: 0 / 0.6921 GB, free: 12.46 MB / 0.5294 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 932 * Number of variables: 932 Notification: Performance of Generate backend data structure: time 0.0196/0.2388, allocations: 6.392 MB / 0.6984 GB, free: 5.938 MB / 0.5294 GB Notification: Performance of prepare preOptimizeDAE: time 5.06e-05/0.2388, allocations: 12.03 kB / 0.6984 GB, free: 5.926 MB / 0.5294 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.001343/0.2402, allocations: 0.5059 MB / 0.6989 GB, free: 5.41 MB / 0.5294 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.005769/0.2459, allocations: 1.138 MB / 0.7 GB, free: 4.27 MB / 0.5294 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.005056/0.251, allocations: 2.212 MB / 0.7022 GB, free: 2.012 MB / 0.5294 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0009798/0.252, allocations: 1.157 MB / 0.7033 GB, free: 0.6719 MB / 0.5294 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.00122/0.2532, allocations: 412.3 kB / 0.7037 GB, free: 276 kB / 0.5294 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01086/0.2641, allocations: 4.539 MB / 0.7081 GB, free: 11.48 MB / 0.545 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0001174/0.2642, allocations: 11.88 kB / 0.7081 GB, free: 11.47 MB / 0.545 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0007088/0.2649, allocations: 160 kB / 0.7083 GB, free: 11.32 MB / 0.545 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 9.09e-05/0.265, allocations: 92 kB / 0.7084 GB, free: 11.23 MB / 0.545 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.008372/0.2734, allocations: 3.392 MB / 0.7117 GB, free: 7.824 MB / 0.545 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.0395/0.3128, allocations: 24.63 MB / 0.7357 GB, free: 13.5 MB / 0.5762 GB Notification: Performance of preOpt comSubExp (simulation): time 0.009014/0.3219, allocations: 3.669 MB / 0.7393 GB, free: 9.777 MB / 0.5762 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.004264/0.3261, allocations: 1.989 MB / 0.7413 GB, free: 7.762 MB / 0.5762 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0004311/0.3266, allocations: 62.34 kB / 0.7413 GB, free: 7.699 MB / 0.5762 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.005856/0.3324, allocations: 2.608 MB / 0.7439 GB, free: 5.031 MB / 0.5762 GB Notification: Performance of pre-optimization done (n=411): time 1.399e-05/0.3324, allocations: 3.938 kB / 0.7439 GB, free: 5.027 MB / 0.5762 GB Notification: Performance of matching and sorting (n=411): time 0.02936/0.3618, allocations: 8.017 MB / 0.7517 GB, free: 12.95 MB / 0.5919 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002316/0.362, allocations: 293.9 kB / 0.752 GB, free: 12.6 MB / 0.5919 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.005454/0.3675, allocations: 2.795 MB / 0.7547 GB, free: 9.805 MB / 0.5919 GB Notification: Performance of collectPreVariables (initialization): time 0.001047/0.3685, allocations: 125.7 kB / 0.7548 GB, free: 9.676 MB / 0.5919 GB Notification: Performance of collectInitialEqns (initialization): time 0.001894/0.3704, allocations: 1.565 MB / 0.7564 GB, free: 8.094 MB / 0.5919 GB Notification: Performance of collectInitialBindings (initialization): time 0.002558/0.373, allocations: 1.488 MB / 0.7578 GB, free: 6.594 MB / 0.5919 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.003404/0.3764, allocations: 1.164 MB / 0.759 GB, free: 5.422 MB / 0.5919 GB Notification: Performance of setup shared object (initialization): time 0.00014/0.3765, allocations: 305.1 kB / 0.7592 GB, free: 5.121 MB / 0.5919 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.005051/0.3816, allocations: 2.375 MB / 0.7616 GB, free: 2.742 MB / 0.5919 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.005873/0.3874, allocations: 3.199 MB / 0.7647 GB, free: 15.32 MB / 0.6075 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.03758/0.425, allocations: 13.97 MB / 0.7783 GB, free: 0.7969 MB / 0.6075 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 3.177e-05/0.4251, allocations: 11.94 kB / 0.7783 GB, free: 0.7852 MB / 0.6075 GB Notification: Performance of matching and sorting (n=892) (initialization): time 0.02336/0.4484, allocations: 8.519 MB / 0.7867 GB, free: 8.18 MB / 0.6231 GB Notification: Performance of prepare postOptimizeDAE: time 0.0002698/0.4487, allocations: 157.5 kB / 0.7868 GB, free: 8.02 MB / 0.6231 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 3.9e-05/0.4487, allocations: 19.98 kB / 0.7868 GB, free: 8 MB / 0.6231 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.3479/0.7966, allocations: 58.27 MB / 0.8437 GB, free: 106.8 MB / 0.6231 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01288/0.8095, allocations: 1.706 MB / 0.8454 GB, free: 105.5 MB / 0.6231 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02005/0.8295, allocations: 16.6 MB / 0.8616 GB, free: 91.25 MB / 0.6231 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.004153/0.8337, allocations: 0.5457 MB / 0.8621 GB, free: 91.01 MB / 0.6231 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0007617/0.8345, allocations: 239.2 kB / 0.8624 GB, free: 90.79 MB / 0.6231 GB Warning: Assuming fixed start value for the following 48 variables: Line12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line12.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line23.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line23Bis1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23Bis1.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line23Bis2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23Bis2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Conv1000.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv1000.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Conv500.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv500.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Conv250.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv250.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Droop.droopControl.firstOrder.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real Droop.droopControl.firstOrder1.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder1.y_start fixed = true ) \"Connector of Real output signal\" type: Real Droop.droopControl.firstOrder2.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder2.y_start fixed = true ) \"Connector of Real output signal\" type: Real Droop.droopControl.firstOrder3.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder3.y_start fixed = true ) \"Connector of Real output signal\" type: Real Conv250.running.value:DISCRETE(flow=false start = Conv250.Running0 fixed = true ) type: Boolean Conv250.udFilterPu:VARIABLE(flow=false start = Conv250.UdFilter0Pu fixed = true ) \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv250.uqFilterPu:VARIABLE(flow=false start = Conv250.UqFilter0Pu fixed = true ) \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv250.idConvPu:VARIABLE(flow=false start = Conv250.IdConv0Pu fixed = true ) \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.iqConvPu:VARIABLE(flow=false start = Conv250.IqConv0Pu fixed = true ) \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.idPccPu:VARIABLE(flow=false start = Conv250.IdPcc0Pu fixed = true ) \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.iqPccPu:VARIABLE(flow=false start = Conv250.IqPcc0Pu fixed = true ) \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.UdcSourcePu:VARIABLE(flow=false start = Droop.dCVoltageControl.UdcSource0Pu fixed = true ) \"DC voltage in pu (base UdcNom)\" type: Real dVOC.dispatchableVirtualOscillatorControl.UFilterRefRawPu:VARIABLE(start = dVOC.dispatchableVirtualOscillatorControl.UFilterRef0Pu unit = \"1\" fixed = true ) type: Real Conv500.running.value:DISCRETE(flow=false start = Conv500.Running0 fixed = true ) type: Boolean Conv500.udFilterPu:VARIABLE(flow=false start = Conv500.UdFilter0Pu fixed = true ) \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv500.uqFilterPu:VARIABLE(flow=false start = Conv500.UqFilter0Pu fixed = true ) \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv500.idConvPu:VARIABLE(flow=false start = Conv500.IdConv0Pu fixed = true ) \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.iqConvPu:VARIABLE(flow=false start = Conv500.IqConv0Pu fixed = true ) \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.idPccPu:VARIABLE(flow=false start = Conv500.IdPcc0Pu fixed = true ) \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.iqPccPu:VARIABLE(flow=false start = Conv500.IqPcc0Pu fixed = true ) \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.UdcSourcePu:VARIABLE(flow=false start = dVOC.dCVoltageControl.UdcSource0Pu fixed = true ) \"DC voltage in pu (base UdcNom)\" type: Real Conv1000.running.value:DISCRETE(flow=false start = Conv1000.Running0 fixed = true ) type: Boolean Conv1000.udFilterPu:VARIABLE(flow=false start = Conv1000.UdFilter0Pu fixed = true ) \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv1000.uqFilterPu:VARIABLE(flow=false start = Conv1000.UqFilter0Pu fixed = true ) \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv1000.idConvPu:VARIABLE(flow=false start = Conv1000.IdConv0Pu fixed = true ) \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.iqConvPu:VARIABLE(flow=false start = Conv1000.IqConv0Pu fixed = true ) \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.idPccPu:VARIABLE(flow=false start = Conv1000.IdPcc0Pu fixed = true ) \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.iqPccPu:VARIABLE(flow=false start = Conv1000.IqPcc0Pu fixed = true ) \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.UdcSourcePu:VARIABLE(flow=false start = Matching.matchingControl.UdcSource0Pu fixed = true ) \"DC voltage in pu (base UdcNom)\" type: Real Line12.running.value:DISCRETE(flow=false start = Line12.Running0 fixed = true ) type: Boolean Line13.running.value:DISCRETE(flow=false start = Line13.Running0 fixed = true ) type: Boolean Line23.running.value:DISCRETE(flow=false start = Line23.Running0 fixed = true ) type: Boolean Line23Bis1.running.value:DISCRETE(flow=false start = Line23Bis1.Running0 fixed = true ) type: Boolean Line23Bis2.running.value:DISCRETE(flow=false start = Line23Bis2.Running0 fixed = true ) type: Boolean Load.running.value:DISCRETE(flow=false start = Load.Running0 fixed = true ) type: Boolean Fault.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean Conv1000.IConv0Pu:VARIABLE(unit = \"1\" fixed = true ) \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real Conv500.IConv0Pu:VARIABLE(unit = \"1\" fixed = true ) \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real Conv250.IConv0Pu:VARIABLE(unit = \"1\" fixed = true ) \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 72 * Number of states: 0 () * Number of discrete variables: 107 ($PRE.Line12.state,Line12.state,$PRE.Line13.state,Line13.state,$PRE.Line23.state,Line23.state,$PRE.Line23Bis1.state,Line23Bis1.state,$PRE.Line23Bis2.state,Line23Bis2.state,$PRE.Load.state,Load.state,$whenCondition1,$whenCondition2,$PRE.Conv1000.state,Conv1000.converter.u,Conv1000.state,$PRE.Conv500.state,Conv500.converter.u,Conv500.state,$PRE.Conv250.state,Conv250.converter.u,Conv250.state,Conv1000.switchOffSignal3.value,Conv1000.switchOffSignal2.value,Conv1000.switchOffSignal1.value,Conv500.switchOffSignal3.value,Conv500.switchOffSignal2.value,Conv500.switchOffSignal1.value,Conv250.switchOffSignal3.value,Conv250.switchOffSignal2.value,Conv250.switchOffSignal1.value,Load.switchOffSignal2.value,Load.switchOffSignal1.value,Line23Bis2.switchOffSignal2.value,Line23Bis2.switchOffSignal1.value,Line23Bis1.switchOffSignal2.value,Line23Bis1.switchOffSignal1.value,Line23.switchOffSignal2.value,Line23.switchOffSignal1.value,Line13.switchOffSignal2.value,Line13.switchOffSignal1.value,Line12.switchOffSignal1.value,$PRE.Conv250.running.value,$PRE.Conv500.running.value,$PRE.Conv1000.running.value,$PRE.Line12.running.value,$PRE.Line13.running.value,$PRE.Line23.running.value,$PRE.Line23Bis1.running.value,$PRE.Line23Bis2.running.value,$PRE.Load.running.value,$PRE.Fault.nodeFault.value,Disconnection.y,Fault.nodeFault.value,Load.running.value,Line23Bis2.running.value,Line23Bis1.running.value,Line23.running.value,Line13.running.value,Line12.running.value,Conv1000.running.value,Conv500.running.value,Conv250.running.value,$whenCondition3,$whenCondition5,$whenCondition4,$whenCondition6,$whenCondition8,$whenCondition7,$whenCondition9,$whenCondition11,$whenCondition10,$whenCondition12,$whenCondition14,$whenCondition13,$whenCondition15,$whenCondition17,$whenCondition16,$whenCondition19,$whenCondition18,$whenCondition21,$whenCondition20,$whenCondition22,$whenCondition24,$whenCondition23,$whenCondition25,$whenCondition27,$whenCondition26,$whenCondition28,$whenCondition30,$whenCondition29,Matching.matchingControl.integrator.local_reset,Matching.voltageLoop.integratorq.local_reset,Matching.voltageLoop.integratord.local_reset,Matching.currentLoop.integratorq.local_reset,Matching.currentLoop.integratord.local_reset,dVOC.dispatchableVirtualOscillatorControl.integrator.local_reset,dVOC.voltageLoop.integratorq.local_reset,dVOC.voltageLoop.integratord.local_reset,dVOC.currentLoop.integratorq.local_reset,dVOC.currentLoop.integratord.local_reset,Droop.droopControl.integrator.local_reset,Droop.voltageLoop.integratorq.local_reset,Droop.voltageLoop.integratord.local_reset,Droop.currentLoop.integratorq.local_reset,Droop.currentLoop.integratord.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (726): * Single equations (assignments): 716 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 3 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 3 systems {(2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 4 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 3 systems {(24,10), (1,1), (12,7)} Notification: Performance of prepare postOptimizeDAE: time 0.002459/0.8369, allocations: 1.048 MB / 0.8634 GB, free: 89.88 MB / 0.6231 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.000799/0.8377, allocations: 416.5 kB / 0.8638 GB, free: 89.7 MB / 0.6231 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01473/0.8524, allocations: 5.694 MB / 0.8693 GB, free: 84.92 MB / 0.6231 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 3.297e-05/0.8525, allocations: 44 kB / 0.8694 GB, free: 84.88 MB / 0.6231 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.852e-05/0.8525, allocations: 4 kB / 0.8694 GB, free: 84.87 MB / 0.6231 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 6.374e-05/0.8526, allocations: 22.09 kB / 0.8694 GB, free: 84.87 MB / 0.6231 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02055/0.8731, allocations: 10.59 MB / 0.8797 GB, free: 76.58 MB / 0.6231 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 3.075e-05/0.8731, allocations: 0 / 0.8797 GB, free: 76.58 MB / 0.6231 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.01098/0.8841, allocations: 1.182 MB / 0.8809 GB, free: 75.58 MB / 0.6231 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.002928/0.8871, allocations: 1.307 MB / 0.8822 GB, free: 74.42 MB / 0.6231 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0009572/0.888, allocations: 98.44 kB / 0.8823 GB, free: 74.34 MB / 0.6231 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.0257/0.9137, allocations: 40.82 MB / 0.9221 GB, free: 30.85 MB / 0.6231 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 4.098e-06/0.9137, allocations: 7.938 kB / 0.9221 GB, free: 30.84 MB / 0.6231 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01861/0.9323, allocations: 8.21 MB / 0.9302 GB, free: 22.52 MB / 0.6231 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001259/0.9336, allocations: 465.9 kB / 0.9306 GB, free: 22.11 MB / 0.6231 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001014/0.9346, allocations: 97.11 kB / 0.9307 GB, free: 22.02 MB / 0.6231 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.002217/0.9368, allocations: 115.9 kB / 0.9308 GB, free: 21.9 MB / 0.6231 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0008975/0.9377, allocations: 361.8 kB / 0.9312 GB, free: 21.55 MB / 0.6231 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0002518/0.938, allocations: 127.9 kB / 0.9313 GB, free: 21.42 MB / 0.6231 GB Notification: Performance of sorting global known variables: time 0.002062/0.94, allocations: 1.725 MB / 0.933 GB, free: 19.71 MB / 0.6231 GB Notification: Performance of sort global known variables: time 9e-08/0.94, allocations: 0 / 0.933 GB, free: 19.71 MB / 0.6231 GB Notification: Performance of remove unused functions: time 0.00408/0.9441, allocations: 1.397 MB / 0.9343 GB, free: 18.31 MB / 0.6231 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 10 * Number of states: 41 (Droop.currentLoop.integratord.y,Droop.currentLoop.integratorq.y,Droop.voltageLoop.integratord.y,Droop.voltageLoop.integratorq.y,Droop.droopControl.firstOrder.y,Droop.droopControl.integrator.y,Droop.droopControl.firstOrder1.y,Droop.droopControl.firstOrder2.y,Droop.droopControl.firstOrder3.y,Conv250.udFilterPu,Conv250.uqFilterPu,Conv250.idConvPu,Conv250.iqConvPu,Conv250.idPccPu,Conv250.iqPccPu,Conv250.UdcSourcePu,dVOC.currentLoop.integratord.y,dVOC.currentLoop.integratorq.y,dVOC.voltageLoop.integratord.y,dVOC.voltageLoop.integratorq.y,dVOC.dispatchableVirtualOscillatorControl.integrator.y,dVOC.dispatchableVirtualOscillatorControl.UFilterRefRawPu,Conv500.udFilterPu,Conv500.uqFilterPu,Conv500.idConvPu,Conv500.iqConvPu,Conv500.idPccPu,Conv500.iqPccPu,Conv500.UdcSourcePu,Matching.currentLoop.integratord.y,Matching.currentLoop.integratorq.y,Matching.voltageLoop.integratord.y,Matching.voltageLoop.integratorq.y,Matching.matchingControl.integrator.y,Conv1000.udFilterPu,Conv1000.uqFilterPu,Conv1000.idConvPu,Conv1000.iqConvPu,Conv1000.idPccPu,Conv1000.iqPccPu,Conv1000.UdcSourcePu) * Number of discrete variables: 53 ($whenCondition29,$whenCondition30,$whenCondition28,$whenCondition26,$whenCondition27,$whenCondition25,$whenCondition23,$whenCondition24,$whenCondition22,$whenCondition20,$whenCondition21,$whenCondition18,$whenCondition19,$whenCondition16,$whenCondition17,$whenCondition15,$whenCondition13,$whenCondition14,$whenCondition12,$whenCondition10,$whenCondition11,$whenCondition9,$whenCondition7,$whenCondition8,$whenCondition6,$whenCondition4,$whenCondition5,$whenCondition3,$whenCondition1,$whenCondition2,Conv250.running.value,Conv250.state,Conv250.converter.u,Conv500.running.value,Conv500.state,Conv500.converter.u,Conv1000.running.value,Conv1000.state,Conv1000.converter.u,Line12.running.value,Line12.state,Line13.running.value,Line13.state,Line23.running.value,Line23.state,Line23Bis1.running.value,Line23Bis1.state,Line23Bis2.running.value,Line23Bis2.state,Load.running.value,Load.state,Fault.nodeFault.value,Disconnection.y) * Number of discrete states: 9 (Conv250.running.value,Conv500.running.value,Conv1000.running.value,Line13.running.value,Line23.running.value,Line23Bis1.running.value,Line23Bis2.running.value,Load.running.value,Line12.running.value) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (371): * Single equations (assignments): 322 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 19 * If-equations: 0 * Equation systems (not torn): 24 * Torn equation systems: 6 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 3 systems {(2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 21 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 4 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 2 systems {(1,1), (24,10)} Notification: Performance of Backend phase and start with SimCode phase: time 0.01886/0.963, allocations: 8.961 MB / 0.9431 GB, free: 9.25 MB / 0.6231 GB Notification: Performance of simCode: created initialization part: time 0.01387/0.9768, allocations: 6.658 MB / 0.9496 GB, free: 2.477 MB / 0.6231 GB Notification: Performance of simCode: created event and clocks part: time 9.658e-06/0.9769, allocations: 8.25 kB / 0.9496 GB, free: 2.469 MB / 0.6231 GB Notification: Performance of simCode: created simulation system equations: time 0.01054/0.9874, allocations: 3.52 MB / 0.953 GB, free: 14.87 MB / 0.6387 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.003837/0.9912, allocations: 0.5413 MB / 0.9536 GB, free: 14.35 MB / 0.6387 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.09634/1.088, allocations: 40.85 MB / 0.9934 GB, free: 4.586 MB / 0.67 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.002417/1.09, allocations: 2.206 MB / 0.9956 GB, free: 2.344 MB / 0.67 GB Notification: Performance of simCode: alias equations: time 0.002646/1.093, allocations: 395.6 kB / 0.996 GB, free: 1.953 MB / 0.67 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.00314/1.096, allocations: 1.792 MB / 0.9977 GB, free: 164 kB / 0.67 GB Notification: Performance of SimCode: time 1.433e-06/1.096, allocations: 4 kB / 0.9977 GB, free: 160 kB / 0.67 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.5025/1.598, allocations: 103.1 MB / 1.098 GB, free: 261.3 MB / 0.7481 GB Notification: Performance of buildModelFMU: Generate platform static: time 23.23/24.83, allocations: 12.62 kB / 1.098 GB, free: 261.3 MB / 0.7481 GB " [Timeout remaining time 635] (rm -f Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe ; mkfifo Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe ; head -c 1048576 < Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe >> ../files/Dynawo_dev_Dynawo.Examples.GridForming.GridForming.sim & /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat --tempDir=temp_Dynawo_dev_Dynawo_Examples_GridForming_GridForming_fmu --startTime=0 --stopTime=3 --stepSize=0.006 --timeout=50 --tolerance=1e-06 Dynawo_dev_Dynawo_Examples_GridForming_GridForming.fmu > Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe 2>&1) [Timeout 52.5] diffSimulationResults("Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat","/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ReferenceFiles/Dynawo/dynawo/sources/Models/Modelica/Dynawo/Examples/references/Dynawo.Examples.GridForming.GridForming_res.csv","/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/Dynawo_dev_Dynawo.Examples.GridForming.GridForming.diff",relTol=0.003,relTolDiffMinMax=0.003,rangeDelta=0.001) [Timeout 660] "" [Timeout remaining time 660] Reference file matches [Calling sys.exit(0), Time elapsed: 30.632019208045676]